What specialist testing can show
TI-5000JX bench. Match the fitted label, position profile and any battery-buffered EBI arrangement before testing.
TI-3000JX motor run. Verify the full motor order and required EnDat motor-run setup.
Starting lead. TI-5713 for the documented 12-contact M17 EnDat 2.2 branch.
STÖBER EZ EnDat 2.2 / M17 Servo Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| EZ, documented M17 EnDat 2.2 branch | Match the complete motor type plate and fitted HEIDENHAIN label. TI-5713 applies to the scoped motor-side connector. |
| EZ with EBI | Identify the battery-buffered encoder and the retention circuit from the motor and drive drawings. |
| ED/EK EnDat | Separate 12-contact M23 connection in Mitchell’s cable index, TI-5629. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Link | Digital EnDat 2.2 for the scoped EZ branch. |
| Connector | 12-contact M17 feedback connector on the Mitchell test lead description. |
| Retention | Read the fitted encoder ID to determine whether EBI retention is present. |
Interface and measuring method
The drive reads serial position and encoder information over EnDat. A battery-buffered EBI also needs its specified retention arrangement. Assess valid live position and retained turn state as two separate checks.
Mounting and fit
Read the EZ frame and encoder suffix, then obtain the corresponding rear assembly drawing. Inspect the motor bulkhead key and strain relief before opening the motor. The frame and OEM assembly decide the mounting seat and internal rotor connection.
Wiring and connector scope
Use the EZ order-specific feedback map and matched M17 mating face. Identify clock and data, supply and return, and any battery path separately. Match the physical keying before selecting the plug.
Internal motor and machine cables
TI-5713 is a test cable. Use the STÖBER cable selection or machine wiring list for the production lead and record the factory internal loom separately.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| M17 connection with no serial response | Confirm the EZ order and trace the approved supply and differential pairs. |
| Turn state lost after shutdown | Check the EBI option and retention circuit against the fitted documentation. |
| Stable position with enable fault | Compare incoming offset, motor identification and drive feedback selection. |
Angle of alignment and commissioning
Record motor type, drive data, feedback direction and stored zero. For EBI, handle retention only under the documented procedure for the fitted motor and drive before changing a cable or unplugging a battery circuit.
Motor and drive applications
STÖBER EZ with the documented 12-contact M17 connection
Distinguish the EZ M17 and optional EBI retention paths from the older ED/EK M23 arrangement.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer. Stober section, TI-5713 EZ / HEIDENHAIN EnDat 2.2 (+EBI)
- STÖBER synchronous servo motors and technical downloads. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.