What specialist testing can show
TI-5000JX bench. Match the full OIH35 label and use the appropriate incremental and commutation checks.
TI-3000JX motor run. Confirm the actual motor and safe run profile separately.
Starting lead. TI-5700 for the documented 17-contact M23.
Tamagawa OIH35 / Applikon Incremental ABZ/UVW Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| OIH35 / TS52□□N3□□ | Tamagawa hollow-shaft series pattern. Read the complete order rather than the pattern alone. |
| Applikon OIH35 | Mitchell application uses a 17-contact M23 for ABZ and UVW. |
| OIH48 / OIH60 | Different envelope and shaft sizes in the Tamagawa catalogue. Match the full type. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Catalogue OIH35 envelope | 35 mm outside diameter and 6 mm motor shaft in the manufacturer family table. |
| Resolution | 500–6,000 counts per turn across the OIH35 family. |
| Electrical | The catalogue lists +5 V and line-driver A/B/Z/U/V/W for the illustrated family. Verify the exact OEM variant. |
Interface and measuring method
A/B direction and position, index Z and commutation U/V/W serve different purposes. Check the index and transitions on the correct input without treating valid A/B counts as proof of correct commutation.
Mounting and fit
Check the bore, mounting restraint, and shaft and sensor alignment against the exact Tamagawa drawing. Preserve the motor reference and encoder orientation before loosening any fitted assembly.
Wiring and connector scope
Use the encoder order sheet and the Applikon motor-side 17-contact view. TI-5700 identifies the scoped test connection. Trace the matched supply, return and signal pairs under the actual wiring diagram.
Internal motor and machine cables
Distinguish the short encoder lead from the 17-contact motor connector and drive extension. Record the fitted harness by both ends and motor order before replacing it.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| A/B counts with an enable fault | Check commutation sequence and phase relationship. |
| Index missed after replacement | Confirm the exact order and trace Z independently. |
| Fault appears only as the cable moves | Inspect the M23 insert, shield bond and strain relief, then isolate-test the loom. |
Angle of alignment and commissioning
Capture the original index and commutation reference to the motor phases with the approved procedure. Verify the complete order and direction before specialist replacement.
Motor and drive applications
Applikon motor fitted with the documented Tamagawa OIH35 connection
Identify the OIH35 motor-side wiring and check the index and commutation independently.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer. Applikon and Tamagawa sections, TI-5700 OIH35 ABZ/UVW
- Generic Incremental Quadrature Pulse Encoders. Supplementary reference for the stated model or setup.
- Tamagawa rotary encoder catalogue. Hollow-shaft section, OIH35 / TS52 family dimensions and signal data.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation