Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified resolver bench test uses the documented compatible excitation and input loading, then measures both return signals through a controlled turn. Compare against a known angle and verify repeatability. Confirm exact fixture and Mitchell adapter compatibility before testing.
TE Connectivity 2367254-1 Two-Pole-Pair Hollow-Shaft Resolver technical reference
Find your part number
Use the full label and suffix. The main reference is 2367254-1. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 2367254-1 / V23401-T2715-B101 | Size 21 hollow-shaft rotor and stator pair. Use drawing 2367254 revision A. | Two pole pairs, nominal resolver sine and cosine channels and separate excitation. |
| 2350437-1 / V23401-T2071-B101 | Separate TE size 21 resolver part. Compare the mechanical drawing. | One pole pair. Electrical-angle scaling differs. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Mechanical family | Size 21, type T2. Use the dimensioned mating and tolerance drawing for the paired rotor and stator. |
| Angle | Two pole pairs. The electrical angle goes through two cycles per mechanical revolution. |
| Stated angular error | TE lists 20 arcmin for 2367254-1. Check installation and receiver conditions for the whole machine. |
| Lead | AWG 26 and 300 mm shown in drawing 2367254. Maintain the documented twisted pairs. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Match both pieces to the same documented assembly. The rotor follows the shaft and the stator locates in the motor housing. Use the exact installed concentricity, axial position and retention detail in the drawing. Check for rubbing and movement under safe isolation before replacing either component.
Interface and measuring method
A compatible resolver-to-digital receiver sends an AC reference and reads two AC return envelopes. The sine and cosine amplitudes change with electrical angle. With two pole pairs, a single electrical reading repeats twice per shaft revolution. The machine must resolve its mechanical reference with the approved design.
Verified wiring
These assignments are the free leads shown on TE drawing 2367254 revision A. Confirm both the machine bulkhead and the drive wiring before applying excitation.
| Function | TE wire marking |
|---|---|
| R1 REF+ / R2/R3 REF− | Red-white / yellow-white |
| S1 COS+ / S3 COS− | Red / black |
| S2 SIN+ / S4 SIN− | Yellow / blue |
Check the receiver's permitted excitation frequency, voltage, transformation ratio and phase conditions against the exact application data. Use the drawing's pair twists and shield arrangement at the mating loom.
Cables inside the motor and at the machine
The drawing documents the resolver free leads. Preserve each winding pair through the motor bulkhead and match the receiver connector using the machine cable drawing. Request the OEM loom code with the motor part number and actual connector photos.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| All return signals absent | Confirm reference excitation at the drive then at the isolated test breakout, and check the disconnected harness. |
| One return channel weak or missing | Verify that pair through the loom. An isolated passive winding continuity check can identify an open, with the assembly fully separated from the drive and harness. |
| Both channels present, wrong position | Confirm polarity, pole-pair setting and rotor/stator reference. Inspect for movement of either part. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The TE part is a passive rotary position transducer for a compatible resolver receiver. Confirm the motor manufacturer, pole-pair expectation, excitation and electrical reference for the actual application.
Angle of alignment and commissioning
Mechanical positioning uses the paired assembly's drawing. Electrical alignment depends on the motor and receiver. Record the original reference and compare the decoded electrical angle at the specified OEM shaft position. Set a new reference only using the approved motor procedure.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- TE one-pole-pair comparison. Use the separate exact order record.