Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use EtherCAT master diagnostics and the manufacturer test procedure. With the hydraulic load secured and the electrical system in the appropriate state, a qualified technician can separate cable, power and magnet faults. Use approved movement tests after assembly.
Temposonics RH5SA0375M02D561U101 EtherCAT Rod Position Sensor technical reference
Find your part number
Use the full label and suffix. The main reference is RH5SA0375M02D561U101. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| RH5SA0375M02D561U101 | RH5 rod, S standard ¾-16 UNF flange, A standard mechanics, 375 mm stroke. Code 02 specifies two magnets. | D56 uses two D-coded M12 network sockets and M8 power. Code 1 is the standard system. U101 sends position, velocity and acceleration. |
| RH5 design M | M18 × 1.5 flange in the manufacturer matrix. | Order the electrical and stroke options separately. |
| RH5 D58 connection option | Power lead connector changes. | D58 uses an A-coded M12 power connector. Use the D58 diagram. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Stroke | 375 mm measuring stroke. Use the drawing for dead zones and total rod length. |
| Flange | Standard ¾-16 UNF-3A, S configuration. Check the cylinder port and seal design. |
| Sensor technology | Non-contact magnetostrictive absolute linear position. For a multi-magnet setup the manual specifies matching magnet types and at least 75 mm between front faces. |
| Power and output | D56 wiring shows 12–30 V DC (±20% as specified in the manual), with independent EtherCAT ports. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The rod projects into the cylinder and the moving magnet tracks the piston. Isolate the hydraulic energy, relieve stored pressure and mechanically secure the load before opening or loosening components. Compare flange, seal, full rod clearance and magnet position with the exact cylinder and sensor drawings.
Interface and measuring method
The moving magnet marks position along the sensing rod. The device sends absolute displacement to the EtherCAT master. Separate physical link and operational state from the process value, status and scaling. Confirm the device description and selected process mapping in the controller project.
Verified wiring
| Connector | Pin assignment on the sensor |
|---|---|
| M8 power | 1 supply, 3 DC ground, 2 and 4 unconnected |
| D-coded M12 port 1 or port 2 | 1 Tx+, 2 Rx+, 3 Tx−, 4 Rx− |
Use the sensor-face views in Figure 98 of the operation manual. Follow the manufacturer shield and grounding instructions. Use the correct port direction and connector coding.
Cables inside the motor and at the machine
Select separate shielded D-coded M12 Ethernet leads and the D56 M8 power lead. Use the accessory and wiring references in the manufacturer's manual and verify connector gender, length and routing against the cylinder assembly.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| EtherCAT will not enter Operational | Check both network links, configured topology, device description and power. |
| Operational with absent or invalid position | Check magnet type, orientation, stroke envelope and the process/status mapping. |
| Position drops at the end of travel | Check the magnet path and available measuring stroke before changing scaling. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The exact number appears as a manufacturer nameplate example. Confirm its fit to the original cylinder and magnet, and match the controller project before treating a different RH5 as a spare.
Angle of alignment and commissioning
Establish the magnet travel and mechanical reference using the hydraulic machine procedure. Compare reported position with the approved machine datum and verify stroke ends within the measuring range.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- R-Series V EtherCAT manual. See the example nameplate, installation instructions, EtherCAT diagnostics and Figure 98 D56 wiring.
- RH5 EtherCAT technical data. Use the rod and flange drawings, order matrix and connector options.