Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a compatible IO-Link master to read device identification, diagnostics and the authorized parameter set. Use the machine's approved safety validation for switching outputs. Confirm any specific Mitchell fixture independently. This is a cam switch and position sensor rather than a motor-run setup.
TWK NOCIO79/S3 IO-Link Switching Cam Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is NOCIO79-KZA2-32768R4096S3T2L01. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| NOCIO79-KZA2-32768R4096S3T2L01 | Published standard S3 example with KZ clamped flange and gear-mating shaft, two axial M12 connectors. | 32,768 positions per turn and 4096 turns in the order key. Verify actual label and IODD. |
| NOCIO79/S0 | Separate profile in TWK family documentation. | Check the documented safety profile for the actual order. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Interface | IO-Link parameter and position path plus separately wired switching contacts. |
| Supply | 18 to 30 V DC operating range for the referenced S3 data sheet. |
| Connections | S1 four-contact male and S2 five-contact female, both M12 A-coded on the standard example. |
| Order key | 79 housing, KZ shaft/flange, 32768 within-turn steps, 4096 turns, S3 profile and T2 axial connectors. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Match the KZ gear-mating shaft, flange seat and measuring gear to the OEM assembly. Secure the coupling and check for play, misalignment or movement before changing any cam settings. Follow the applicable TWK mounting drawing and machine risk controls for shaft and coupling selection.
Interface and measuring method
The IO-Link master exchanges data and parameters with the device through S1. The switching contacts are on S2 and belong to their own circuit. Use the exact variant IODD and device identity. A readable IO-Link value confirms communication at that moment. The safety contact circuit requires its own approved functional validation.
Verified wiring
TWK illustrates the device connector contact side. S1 is male and S2 female. Verify the connection sheet TY supplied with the actual device, since customer configurations can differ.
| Contact or group | Function |
|---|---|
| S1 1 / 3 / 4 | L+ / L− / IO-Link C/Q |
| S2 1 and 3 | Safety contact path, terminals 13 and 14 in the standard sheet |
| S2 2 and 4 | Relay 2 path, terminals 23 and 24 in the standard sheet |
| S2 5 | Unused on the standard diagram |
Cables inside the motor and at the machine
Choose two matching leads for the distinct S1 and S2 connectors. Follow the TWK contact view, voltage and cable requirements and the machine wiring plan. Use the maker’s shielding and PE instructions where the declared EMC conditions apply. The exact machine cable orders depend on connector, length and protection requirements.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Master reports an IODD or device identity mismatch | Compare the complete order, variant and IODD before changing any parameters. |
| Position reads correctly and the safety circuit reports a fault | Have a qualified safety technician compare the S2 wiring and approved safety configuration. |
| Switch position drifts with motion | Inspect gear or coupling play and mechanical reference. Verify cam settings with the authorized validation process. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This is an external machine cam switch application. Match the installed S3 variant, IODD, safety circuit and machine function. A previously saved parameter set requires the exact approved configuration before it is restored.
Angle of alignment and commissioning
Capture mechanical zero and the approved cam parameters before service. Verify the actual reference, position direction and each required switching point under the machine safety commissioning procedure. Keep the machine in its approved safe state during tests and record the functional validation.
Drawings, pin maps and manuals
- Main technical PDF. TWK NOC 15893 DE. Reference S3 order example, mechanical drawings and standard S1/S2 contact assignments.
- Manufacturer reference. Match the exact order code or the identified motor option.
- TWK NOC 15597 EE user manual. IO-Link communication, variant IODD, connector roles and diagnostics.