Identify the fitted part
| Guide scope | Yaskawa SGMGV-20A3A2C — motor feedback application |
|---|---|
| Feedback identity | UTTAH-B20 by Mitchell code 3; fitted label to verify |
| Main model / application identifier | SGMGV-20A3A2C |
| Motor order scope | OEM catalogue order, not an inspected unit: SGMGV-20A3A2C |
| Interface | 20-bit serial absolute, battery-retained turns |
| Starting connection | TI-5762 / TI-5763 / TI-5765 / TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | TI-5000JX bench scope for the named Sigma family and 20-bit serial absolute, battery-retained turns. Match the fitted label and enabled software, rotate slowly for count checks and use the exact connection drawing. Distinguish the OEM serial feedback path from any test-display commutation or revolution counter. |
|---|---|
| Starting lead / fixture | TI-5762 / TI-5763 / TI-5765 / TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing. |
| Profile / module | Select the exact Yaskawa serial profile manually: Athena ENCODER ID may show ----. Mitchell does not support reading this encoder motor memory; preserve factory keying and use the exact motor/encoder identity for replacement. |
| TI-3000JX motor-run scope | No TI-3000JX motor-run support for Yaskawa serial encoders is offered in the current Mitchell testing article. This guide admits TI-5000JX feedback bench evaluation only; no motor-run capability is inferred. |
The documented test reference is Yaskawa Serial Encoder Identification — Mitchell SGMGV family and feedback code 3; OEM drawing 900-008-900. . Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
The linked manufacturer record documents this configuration. Current production, stock and an approved successor for the complete fitted order still require manufacturer confirmation. A historical manual or downloadable CAD drawing does not prove present availability. Match voltage, mounting, shaft, brake, feedback, connector and motor-data requirements before ordering.
Specifications and interface
| Feedback technology | 20-bit serial absolute, battery-retained turns |
|---|---|
| Exact catalogue order | SGMGV-20A3A2C |
| OEM drawing number | 900-008-900 |
| Motor voltage class | 200 V; not the feedback supply |
| Feedback code | 3: 20-bit absolute serial with retained turns |
| Shaft / brake / seal arrangement | plain shaft; 24 V holding brake |
| Rated motor output | 1.8 kW |
| Service values | Encoder coupling dimensions, exact pin map and tightening torque require the fitted assembly drawing. No value is inferred from a related motor. |
Check within-turn position and the documented retention circuit separately. Loss of retained turns, an incorrect profile and a damaged serial link can present differently. Record the original drive alarm and retention state before any reset or battery work.
Mechanical fit and retention
Record the incoming shaft datum, pilot, bolt pattern, rear clearance, cable exit and retaining arrangement before removal. Use the exact drawing for tolerances and fastening. Do not infer encoder coupling dimensions or tightening torque from the motor flange size. Inspect looseness, bearing play, debris and moisture before disturbing the feedback attachment. The plain shaft; 24 V holding brake configuration is material to replacement fit. Compare shaft diameter and end treatment, pilot, bolt pattern, brake-dependent length and rear cable clearance with drawing 900-008-900. Support the load independently of the holding brake and keep the brake circuit separate from feedback power.
SGMGV-20A3A2C is the exact catalogue configuration identified by OEM drawing 900-008-900. 1.8 kW, 200 V; plain shaft; 24 V holding brake. Check 20-bit absolute retention feedback. The drawing describes a catalogue order, not an inspected customer motor.
Wiring and connector boundaries
Keep motor power, protective earth, feedback, temperature sensing and any holding brake as separate circuits. Establish contact numbering, keying, gender and whether the drawing shows the mating face or wire side. Do not infer a pin map from a connector shell. The exact OEM drawing and actual connector face must select the test lead. TI-5762 / TI-5763 / TI-5765 / TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing. The drawing document number is not an encoder service part number. Confirm the feedback supply and contact view from the matched cable drawing before connection.
Starting connection for this guide: TI-5762 / TI-5763 / TI-5765 / TI-5766 are Sigma-V candidates only; select by the exact motor connector and cable drawing.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
Record the internal encoder-to-motor loom separately from the external machine cable and test fixture. The internal loom part number is not established by the motor model alone. Obtain the assembly drawing and both connector faces. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation; a Mitchell test lead is not an OEM replacement cable.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Identify before testing | SGMGV-20A3A2C is the exact catalogue configuration identified by OEM drawing 900-008-900. 1.8 kW, 200 V; plain shaft; 24 V holding brake. Check 20-bit absolute retention feedback. The drawing describes a catalogue order, not an inspected customer motor. |
|---|---|
| Intermittent fault with cable movement | After isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and previous repairs. Compare continuity and unintended shorts with the exact diagram, allowing for intentional shield bonds. |
| No serial data or unstable position | Confirm the profile, low-voltage supply at the correct boundary and mating-face pin assignment. Compare the test fixture with the actual motor connector; a plausible connector fit does not prove electrical compatibility. |
| Feedback reads but the drive rejects it | Record the original alarm and check exact motor identity, stored data requirements, direction, mechanical attachment and the supported signal paths. A reset is not proof of a compatible replacement. |
| Replacement dimensions look close | Compare the exact model, shaft, pilot, brake, seal, cooling and connector options above with the linked drawing before ordering or removing the original assembly. |
| Athena identity appears blank | A ---- identity display is expected in the documented support. Select the profile from the fitted motor/feedback identification; do not claim that Athena read or confirmed the stored motor model. |
Alignment, reference and memory
Preserve the original mechanical reference, motor phase convention, direction and readable drive data before disassembly. Use the fitted motor and encoder service procedure for replacement. Communication alone does not prove correct alignment or machine origin. The factory encoder key relationship can be disturbed during repair. Record its position before removal. Mitchell cannot read the stored motor identity in this scope, so a replacement from a different motor model is not established as compatible.
Motor and drive applications
SGMGV · 1.8 kW, 200 V; plain shaft; 24 V holding brake. Check 20-bit absolute retention feedback.. SGMGV-20A3A2C is the exact catalogue configuration identified by OEM drawing 900-008-900. 1.8 kW, 200 V; plain shaft; 24 V holding brake. Check 20-bit absolute retention feedback. The drawing describes a catalogue order, not an inspected customer motor.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Exact OEM outline drawing 900-008-900 — SGMGV-20A3A2C
- Yaskawa Serial Encoder Identification — Mitchell SGMGV family and feedback code 3; OEM drawing 900-008-900.
- Yaskawa Serial Encoder Testing — Named motor family and feedback option; row locator identifies scope
- Yaskawa Sigma-5 Rotary Servomotors, YEA-KAEPS80000042L — SGMGV, SGMSV and SGMCS model keys and external dimensions
- Yaskawa SGMGV-20A3A2C dimensional drawing 900-008-900 — Document title, description, PDF and DXF download; exact motor order
Obtain the complete fitted motor and encoder labels, exact service ID, internal loom, connector mating-face drawing and approved setup. Match the linked OEM document revision; unverified supply, pins, retention fasteners and alignment values remain open. Yaskawa serial TI-3000JX run and encoder-memory reading remain unsupported in the checked Mitchell article.
Common questions
What should accompany a SGMGV-20A3A2C enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
No TI-3000JX motor-run support for Yaskawa serial encoders is offered in the current Mitchell testing article. This guide admits TI-5000JX feedback bench evaluation only; no motor-run capability is inferred. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation