What specialist testing can show
TI-5000JX bench. Confirm label, motor code, absolute serial position and the retention arrangement for the fitted unit.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. Mitchell lists TI-5762, TI-5765 and TI-5774 for Sigma-7 connections. Select the lead by the fitted motor order and plug.
Yaskawa UTTAH-B24RK21 Sigma-7 ID 7 Absolute Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| UTTAH-B24RK21 · ID 7 | 24-bit absolute in Mitchell’s Sigma-7 identification table. |
| UTTAI-B24 · ID 7 | Another label listed under the same ID. Verify the fitted hardware and motor before substitution. |
| UTTAH-B24RU21 · ID 6 | Separate 24-bit absolute table entry. Compare the full label and fitted motor. |
| UTTSI-B24 · ID F | 24-bit incremental serial branch. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position format | 24-bit absolute for the RK21 ID 7 entry. |
| Motor family | Sigma-7. Match the full motor order and connector. |
| Retention | Use the matched Yaskawa documentation to confirm the installed absolute backup arrangement. |
Interface and measuring method
Check the serial response and the configured position format. Record how the fitted drive retains the machine’s position before touching the backup circuit.
Mounting and fit
Use the complete Sigma-7 motor and encoder drawings. Save the original shaft reference, mounting and internal cable route before disassembly.
Wiring and connector scope
Compare the fitted motor and SERVOPACK connector drawings. Mitchell lists several Sigma-7 leads. Confirm the correct pin view and cable before connecting.
Internal motor and machine cables
Trace the factory encoder lead and motor-to-drive extension separately. Record the battery or retention connection where present using the matching documentation.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position present but the drive flags the type | Compare RK21 ID 7, RU21 ID 6 and the fitted motor code. |
| Reference lost after power cycling | Review the approved backup path and absolute setup. |
| Serial dropout under movement | Inspect connector retention and the isolated feedback cable. |
Angle of alignment and commissioning
Capture direction, machine datum and original drive setup. Follow the Yaskawa procedure for preserving or restoring the absolute reference.
Motor and drive applications
Yaskawa Sigma-7 with the documented ID 7 profile
Identify the ID 7 RK21 profile and distinguish it from ID 6 RU21 before selecting a replacement or test.
Related SpareFaber guides
Drawings, pin maps and manuals
- Yaskawa Serial Encoder Identification. Encoder identification table, ID 7, 24 bit ABS, UTTAH-B24RK21 and UTTAI-B24
- Yaskawa Sigma-7 rotary servomotor installation and connection manual. Supplementary reference for the stated model or setup.
- Yaskawa Serial Encoder Testing. Reference for the fitted feedback or motor option.
- Yaskawa Sigma-7 rotary servomotor product manual. Official motor, connector and encoder cable procedures. Use the section for the fitted motor.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.