What specialist testing can show
TI-5000JX bench. Select 20-bit INC and check communication, count behavior and applicable commutation indicators.
TI-3000JX motor run. Match the actual Sigma motor and available run profile before assigning TI-3000JX coverage.
Starting lead. Mitchell lists TI-5762, TI-5764, TI-5765 and TI-5766 across the relevant family connectors. Use the one documented for the exact fitted motor.
Yaskawa UTTIH-B20 20-Bit Incremental Serial Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| UTTIH-B20 · ID D | Mitchell identification table lists 20-bit INC for Sigma-II and Sigma-V. |
| UTTAH-B20 · ID 3 | The documented 20-bit ABS branch. Read the whole encoder model and the actual profile. |
| Motor encoder option | The Sigma motor nameplate option identifies the installed family. Verify the connector and the reported ID on the fitted motor. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Serial within-turn scale | 20 bits, corresponding to 1,048,576 distinguishable counts per mechanical revolution in the stated encoding. |
| Classification | Incremental serial in Mitchell’s D row. |
| Tester behavior | Mitchell’s 20-bit INC position display has a limited turn field, and the test article describes applicable commutation indicators. |
| Connection | Use the Sigma-II or Sigma-V connector table and the exact drive/motor drawing. |
Interface and measuring method
The drive receives a serial position and status response. The word incremental describes this feedback option’s position and reference behavior. Use the matching serial profile to evaluate it.
Mounting and fit
Match the full Yaskawa motor and encoder labels. Use the appropriate Sigma outline for the motor and the fitted internal drawing for mounting and cable exit. Record the original index and coupling relationship where accessible.
Wiring and connector scope
Use the exact Sigma-II or Sigma-V motor connection. Match the serial pair, power and return at the fitted plug, and confirm the approved cable and view before connecting.
Internal motor and machine cables
Identify the internal loom and drive cable from the motor and SERVOPACK orders. Use the Yaskawa and Mitchell tables to select the matching connector. Preserve the documented shield arrangement.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Profile reads zero or wrong scale | Check the D identifier, 20-bit INC software selection, actual connector and fitted label. |
| Drive loses feedback during travel | Check flex points, strain relief and serial pair continuity in the full isolated harness. |
| Position reads but homing fails | Compare configured feedback type and machine reference recovery with the drive procedure. |
Angle of alignment and commissioning
Save machine and drive parameters, mechanical reference and any available feedback record. Verify count direction and reference recovery after fitting under the OEM procedure.
Motor and drive applications
Yaskawa Σ-II / Σ-V
Identify the INC label and read ID D before comparing the visually similar UTTAH-B20.
Related SpareFaber guides
Drawings, pin maps and manuals
- Yaskawa Serial Encoder Identification. Encoder ID table, D row and Σ-II / Σ-V connection sections
- Yaskawa Serial Encoder Testing. Supplementary reference for the stated model or setup.
- Yaskawa Sigma-V design and maintenance manual. Motor type codes and drive-side connection context for the applicable Sigma-V setup. Read the motor-specific drawing for exact wiring.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.