Site visit or send-in evaluation
Share the complete catalogue number and series, controller and project revision, module fault and LED states. Record the current position reference and scaling. Include photos of the coupling and the three rear ports. Use the enquiry form to share the details.
What specialist testing can show
A compatible EtherNet/IP engineering station can check identity, network link, cyclic I/O, scaling and preset on an isolated setup. A qualified technician can compare supply at the load and read the Net, Mod, Link and Encoder LEDs against the manual. Exact Mitchell TI-5000JX or TI-3000JX support was not verified for this standalone EtherNet/IP encoder. Rockwell 842E setup, diagnostics and network manual (PDF)
Allen-Bradley 842E-MIP1BA EtherNet/IP Encoder technical reference
Find your part number
Copy the entire catalogue code and the device series. In 842E-MIP1BA, M identifies multiturn, IP identifies EtherNet/IP, 1 is the 9.52 mm solid shaft code and B specifies the M12 connector. The order suffix and the separate hardware-series marking matter when choosing a firmware and EDS.
| Catalogue code | Measurement | Mechanical difference |
|---|---|---|
| 842E-MIP1BA | EtherNet/IP multiturn, up to 30-bit total position | 9.52 mm (3/8 in) solid shaft |
| 842E-SIP1BA | EtherNet/IP singleturn, up to 18-bit singleturn | 9.52 mm (3/8 in) solid shaft |
| 842E-MIP2BA | EtherNet/IP multiturn | 9.52 mm solid shaft with a flat |
| 842E-MIP8BA | EtherNet/IP multiturn | Ø10 mm hollow shaft |
Rockwell 842E catalogue codes (PDF) · Exact 842E-MIP1BA record
Production and end-of-life status
Rockwell marks 842E-MIP1BA discontinued on 15 December 2023 and identifies a functional replacement category. Its migration note covers the 843E family. Confirm the required shaft, topology, firmware and controller configuration before selecting a replacement. Reviewed 7 November 2026. Rockwell exact lifecycle record · Rockwell 842E-to-843E migration note · 843E/843ES user manual (PDF)
Specifications
| Parameter | Value |
|---|---|
| Measurement | Optical absolute multiturn |
| Resolution | Up to 18 bits singleturn (262,144 steps), 12 bits multiturn (4096 revolutions), 30 bits total. Scaling depends on controller settings. |
| Supply | 10–30 V DC per the exact product record |
| Network | EtherNet/IP with IEEE 1588 per exact record. Two M12 network ports and a separate power port. |
| Mount | Solid 9.52 mm shaft, encoder with its own bearings. Use the solid-shaft outline and flexible coupling. |
Use the exact catalogue supply rating. Some general 842E wiring publications show a different upper limit. Confirm the label and relevant publication before energizing the device. Exact Rockwell electrical data · 842E operating principle (PDF)
Mounting and fit
Secure the encoder flange to its bracket and use a suitable flexible coupling between the machine and the 3/8 in solid encoder shaft. Align radial, axial and angular position according to the coupling manufacturer. Rockwell warns that a rigid coupling can damage the bearings. Check for slipping hubs, loose mounting screws and excessive preload before adjusting network parameters. Solid-shaft and coupling drawings (PDF)
Interface and measuring method
The encoder reads its optical position and sends a numeric value through EtherNet/IP. The controller’s I/O connection and encoder profile determine which data it receives. A link LED verifies the physical Ethernet connection, while the controller’s module status verifies cyclic I/O. Compare the raw position with the scaled machine value and preset before replacing the encoder.
Rockwell distinguishes Series A from Series B firmware capability. Check the actual nameplate series, EDS and project hardware entry before downloading or migrating a configuration. Rockwell encoder overview and EDS setup (PDF)
Verified wiring
| Port | Pin assignment | Connection check |
|---|---|---|
| Power M12 | 1 supply positive, 3 DC return. 2 and 4 unused. | Identify the power port and correct cordset before applying voltage. |
| Link 1 / Link 2, D-coded Ethernet | 1 TX+, 3 TX−. 2 RX+, 4 RX−. | Use shielded industrial Ethernet cable and the documented connector face. |
Use Link 1 for the documented star configuration and follow the manual for linear or ring networks. The connectors serve different circuits despite both being M12. Rockwell port layout and pinout (PDF) · Rockwell wiring and topology (PDF)
Cables inside the motor and at the machine
| Part number | Role |
|---|---|
| 889D-F4AC-2 | 4-pin DC Micro QD power cordset, 2 m in the installation instructions. |
| 889D-F4ACDM-2 | 4-pin DC Micro QD power patchcord, 2 m in the installation instructions. |
| 1585D-M4TBJM-2 | M12 D-coded male/male industrial Ethernet patchcord listed in 842E-IN001. Confirm the required length and endpoints. |
This encoder mounts externally, so the service cable is the machine or network lead. Use the approved lead for the port and preserve the intended shield and bend radius. Rockwell Suggested Mating Cables (PDF)
Fault checks
Isolate the machine before disconnecting the encoder or altering the coupling. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect. Check port labels, bent pins, liquid or debris, plug retention, cable support, loose flange and coupling slip. Record LED state before isolation.
- Check disconnected leads. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Use a cable tester rated for the Ethernet link when pair quality is suspect.
- Check power and link separately. A qualified technician can fit an approved breakout while off and measure DC across power pins 1 and 3 under load. Check Link and Mod LEDs, IP settings and duplicate addresses. Keep uncommissioned equipment off the live network until its address is verified.
- Check the position path. Link with no I/O suggests address, EDS, module or controller configuration. Good I/O with wrong travel suggests shaft slip, scaling, preset or direction. Intermittency with movement calls for checking the connector and cable.
Motor and drive applications
Rockwell documents configuring 842E in RSLogix 5000 with an EDS and encoder module settings. Match the controller and hardware series to the applicable chapter. The 842E-CM integrated-motion model uses a separate manual and order code. The standard 842E-MIP guide applies to the named product. Rockwell controller integration (PDF) · 842E, 842E-CM and 843E documentation
Angle of alignment and commissioning
Record the machine datum, direction, step scaling, total range and preset before replacement. Restore only the configuration authorized for the same axis. Verify a known position, direction and position across a turn boundary before enabling motion. If migrating to 843E, compare mechanical fit and I/O mapping and recommission the position reference. A separate motor commutation offset follows the motor maker’s procedure.
Drawings, pin maps and manuals
- Rockwell 842E-IN001 installation instructions (PDF). Model codes, mounting, couplings and suggested mating cables.
- Rockwell 842E-UM001 user manual (PDF). Power, network, hardware series, EDS, diagnostics and preset.
- Rockwell 842E-PP001 product profile (PDF). Separate Ethernet and power connector assignments.
- Rockwell 843-UM001 migration target manual (PDF). Check the relevant 843E configuration when selecting a replacement.