Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
With a correctly loaded fixture, compare all twelve outputs and latch action while moving the shaft through a known turn. Inspect the error signal and receiver thresholds. Confirm Mitchell support for the exact parallel output and approved test fixture if needed.
AMCI DC25F-B1A4AS Parallel Binary DuraCoder Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is DC25F-B1A4AS. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| DC25F-B1A4AS | Square flange, 3/8 in solid shaft, side connector, nitrile seal per the order key. | 4,096 natural-binary counts, level update, high-true sourcing outputs. |
| DC25 scaling code 3 | Select the shaft and flange options separately. | 4,096 Gray-code counts. The PLC must decode the selected word format. |
| DC25 update option B | Check complete configuration before choosing a part. | Edge-update behavior. The host input logic must match. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 12-bit singleturn natural binary, 4,096 counts on code 4. |
| Supply | 10.8–26.4 V DC, up to 1.5 W in the AMCI product specification. Check receiver limits separately. |
| Outputs | High-true single-ended sourcing, 24 V DC maximum per the option table. Level update input. |
| Fit | 2.65 in square flange, 3/8 in solid shaft, side connector. Use the flange and shaft drawing. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Measure the shaft, flange pilot and coupling position before installing. Keep shaft loads and misalignment within the selected flange and coupling limits. The side connector needs room for the mating shell and cable bend. Compare the full code if a different connector direction is proposed.
Interface and measuring method
The DuraCoder uses resolver-based sensing internally and sends a parallel absolute digital word. In this option, 12 binary output lines carry the angle. The level-update input determines when the word updates. Check logic level, bit order and latch state before interpreting a fixed or non-monotonic value.
Verified wiring
AMCI documents the lettered 19-contact connector, military equivalent MS3112E14-19P. Match the view and use the binary column.
| Contacts | Function |
|---|---|
| A, B, C, D, E, F, G, H, J, K, L, M | Bits 0 through 11, in order |
| N / P / R | Error output / test input / direction |
| S / T / U / V | Case ground / DC return / latch / DC supply |
Match the PLC input common and current-sourcing logic. Keep the test input and direction wiring in the documented operating state.
Cables inside the motor and at the machine
AMCI lists MS-19, equivalent MS3116F14-19S, as a mating connector and CDCAB-X as an optional cable ordered by length in feet. Verify shell view, wire gauge and screen and check the PLC-end termination against the machine schematic.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Position word is static | Check the level-update input, DC supply and common. Use the test feature only as documented. |
| Position jumps by one binary weight | Trace the affected bit through the isolated loom and compare the receiver input. |
| Data changes consistently but is wrong | Verify binary decoding, bit order, direction and mechanical coupling against known motion. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use with a compatible multi-input PLC or control interface. Confirm the existing channel assignments, sourcing compatibility and input filtering. The side-connector order is a separate fit from axial-connector variants.
Angle of alignment and commissioning
Record the shaft orientation, count direction and machine reference. Align the coupling and verify the reported word at known positions before releasing the machine. Check latch behavior during commissioning and apply the machine's approved datum.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Exact configured code corroboration. Use AMCI's manual for wiring and limits.