Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
AMCI’s troubleshooting PDF covers checking its receiver, cable and transducer. A qualified technician can compare excitation and the two return paths with the matched AMCI test setup. Confirm any Mitchell resolver fixture, frequency and interface before use. This transducer is an external machine sensor.
AMCI HT-20-10 Geared Multiturn Resolver Transducer technical reference
Find your part number
Use the full label and suffix. The main reference is HT-20-10. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| HT-20-10 | HT-20-X external transducer with 10:1 mechanical reduction per AMCI. | Geared single resolver. Match machine travel to the 10-turn scale. |
| HT-20 | Separate single-turn assembly. | Compare shaft measurement and receiver scaling. |
| HTT-20-X | Separate geared dual-resolver series. | Use its distinct interface and cable drawing. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Travel ratio | 10 input shaft turns per resolver revolution for HT-20-10. |
| Signal method | Passive single resolver, with AC excitation and two angle-dependent returns. |
| HT-20-X 2–24 turn family values | AMCI lists 5 kHz excitation, 7.0 V RMS rotor input and 6.65 V RMS stator output under the stated test condition. Use the matched AMCI interface. |
| Shaft and connector | 5/8 inch keyed shaft and MS3102E16S-1P-equivalent device connector per family page. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
The transducer mounts to the machine and couples to its input shaft. Check the shaft key, coupling and bracket alignment and avoid side loads beyond the OEM specification. Inspect for backlash and slip before changing the reported scale. Identify the mechanical travel endpoints before moving the coupling.
Interface and measuring method
The receiver supplies an AC reference and uses two resolver returns to determine angle. Internal gearing maps ten input shaft turns to one resolver cycle. A wrap at the end of that range can be expected in the appropriate setup. A wrap in the middle of travel calls for checking coupling slip, zero and receiver scaling.
Verified wiring
Confirm the connector designation and view using AMCI’s drawing. This table applies to the documented HT-20-X connector. Use the receiver’s own terminal drawing for the other end.
| Contact or group | Function |
|---|---|
| A / B | R1 / R2 excitation |
| F / G | S1 / S3 pair |
| E / C | S2 / S4 pair |
| D | Unused per AMCI |
Cables inside the motor and at the machine
AMCI lists mating connector options MS-16 straight, MS-18 right-angle and MS-161 watertight for the stated connector. Select a transducer cable for the exact AMCI input module. Match the excitation and each return pair, shield and the installed cable length. Verify a replacement cable against the interface drawing.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Receiver shows loss of transducer | Check the approved excitation at the documented test point and trace the disconnected cable to the device. |
| Position jumps under load or on direction change | Inspect key, coupling backlash and bracket. Compare both return channels with the receiver’s expected response. |
| Position wraps early | Check the label ratio, mechanical travel, zero and scaling in the AMCI receiver. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this assembly as a machine-position transducer with the matching AMCI resolver input. Confirm the receiver part, configured range and connector. For an external resolver with different gearing or pinout, use its own product documentation.
Angle of alignment and commissioning
Set the machine reference and 10-turn travel range under the equipment commissioning procedure. Check the coupled shaft against known positions and confirm the controller counts in the intended direction. Recheck both ends of travel before returning the axis to operation.
Drawings, pin maps and manuals
- Main technical PDF. AMCI HT-20-(X) installation drawing. Check the transducer mounting and wiring against the 10-turn configuration.
- Manufacturer reference. Match the exact order code or the identified motor option.
- AMCI resolver selection FAQ. The HT-20-10 example describes the 10-turn geared device.
- AMCI resolver system troubleshooting PDF. Receiver, cable and transducer fault checks.
- AMCI manual index. Select HT-20-(X) for the single geared resolver. The HTT series is separate.