Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
An approved counter or scope fixture can compare A/B order, Z frequency and output behavior under the correct loading. Confirm any Mitchell fixture and voltage range separately.
Autonics E40S6-1000-3-T-24 Totem-Pole Incremental Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is E40S6-1000-3-T-24. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| E40S6-1000-3-T-24 | E40 shaft version, Ø6 mm, standard cable order. | 1,000 P/R, A/B/Z, totem-pole output, 12–24 V DC class. |
| E40 variants with other output letters | The shaft and case can appear similar. | NPN open collector and line-driver versions need different input and wiring arrangements. |
| E40S6-1000-3-T-24-C | Connection variant of the E40 range. Confirm its own connector diagram. | Do not assign pin numbers to a cable without checking the exact suffix. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Mechanical | Ø40 mm body class and Ø6 mm shaft for E40S6. See E40S outline. |
| Resolution | 1,000 pulses per revolution. The PLC’s quadrature count mode determines displayed counts per turn. |
| Output | Code 3 is A/B/Z. Code T is totem-pole output. |
| Supply | Code 24 is 12–24 V DC nominal, ±5% as specified in the family instructions. |
| Connection | Use the standard cable colour table for the exact no-connector version. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use a properly aligned Ø6 mm coupling and support the encoder on its flange. Check axial clearance and radial load against the E40S drawing. Prevent the pigtail from pulling on the housing during machine travel or guard movement.
Interface and measuring method
A and B are phase-shifted pulses. The input uses their order for direction and the Z channel for a reference event. The totem-pole circuit actively drives the logic states. Match the receiver levels and input circuit before connecting.
Verified wiring
For the Autonics E40 T-output cable version, use the cable legend in the manual. Confirm any machine splices from the terminal drawing.
| Contact or group | Function |
|---|---|
| Brown / blue | Supply +V / return. |
| Black / white / orange | A / B / Z. |
| Shield | Frame ground according to the installation instructions. |
Cables inside the motor and at the machine
Use the factory pigtail and the approved machine extension or terminal layout. Check shield, return and maximum cable length from the installation. Match the exact suffix before using a connectorized E40 accessory.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Count on A but no correct direction | Check B, the PLC input assignment and the selected count mode. |
| A/B count is sound but the datum never appears | Verify Z at the receiver during a complete controlled revolution and confirm the PLC’s reference logic. |
| Counts jump at high speed | Check the input frequency rating, cable routing and return. Compare measured signal quality under the documented load. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use for incremental counting, direction and reference with an input rated for the selected output. Record the PLC high-speed input model and existing count mode before replacing.
Angle of alignment and commissioning
Restore the coupling position and machine datum, then verify direction and Z capture on the commissioned axis. Absolute servo commutation is outside this A/B/Z device’s scope.
Drawings, pin maps and manuals
- Main technical PDF. Autonics E40 instruction manual. Match shaft diameter, code T, supply code 24 and the cable drawing.
- Manufacturer reference. Autonics regional E40 series product reference.
- Autonics TCD210019AA instruction reference. Alternate manufacturer-authored instruction copy with output and wiring tables.