Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a CANopen interface, correct EDS and a secure rotary fixture to observe heartbeat, process data and configuration. Separate a network or controller fault from encoder response with a known-good connection. No exact Mitchell test profile is established here.
Baumer EAM360-SWA CANopen Magnetic Multiturn Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is EAM360-SWA.5NC6.14180.A. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| EAM360-SWA.5NC6.14180.A | Ø36 mm body, Ø10 × 16 mm solid shaft with flat. | CANopen, 14-bit singleturn, 18-bit multiturn, 5-pin M12. |
| EAM360-SWA.5LC6.14180.A | Related solid-shaft version. Verify the actual drawing. | CANopen Lift profile. Confirm application and controller support. |
| EAM360-BDC.5NC6.14180.A | Related hollow-shaft construction. | CANopen variant. Different mechanical arrangement. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Supply / connector | 10–30 V DC, 5-pin M12 flange connector. |
| Position capacity | 16,384 steps/rev and 262,144 turns. |
| Absolute accuracy | ±0.15° at +20 ±15 °C. ±0.25° over −40 to +85 °C. |
| Fit / protection | Ø36 mm flange, Ø10 × 16 mm solid shaft with flat, IP65 without shaft seal. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Check the flange, locating surfaces and shaft flat in the exact product's drawing. Use a coupling that matches the shaft and keeps application thrust and misalignment within limits. Confirm hub seating and prevent slip on the shaft. Apply only the torque values specified for the actual hardware.
Interface and measuring method
This magnetic encoder sends absolute angle and turns over CANopen. The PLC or drive uses the exact EDS and device configuration to interpret the process data objects. Configuration and diagnostics are read through CANopen services. Network traffic can be valid while scaling, direction or the preset is wrong.
Verified wiring
This map is the non-redundant CANopen column in the Baumer manual section 14.3 for the single M12 connector. Match the marked contact numbers at the device face and check the mating side of the cable.
| Pin | Function |
|---|---|
| 1 | CAN_GND |
| 2 | +Vs, 10–30 V DC |
| 3 | Supply 0 V |
| 4 | CAN_H |
| 5 | CAN_L |
Follow the bus diagram for reference ground, shielding and end termination. Use the EDS and CANopen manual for this interface.
Cables inside the motor and at the machine
Baumer lists A-coded straight M12 female cable assemblies 11279185, 11279186 and 11279187 on the exact item page. Check the accessory length, CAN wiring, shield and far-end termination. Match the branch or trunk topology already in the machine.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No heartbeat or PDO | Check powered supply, CAN polarity, node ID, bus speed, NMT state and termination before replacing the encoder. |
| Communicates but value is static | Read raw position and verify coupling motion, PDO configuration and the PLC tag update. |
| Position differs after replacement | Check counts per revolution, total range, direction and position preset against the recorded configuration. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use with a compatible CANopen controller on an industrial rotary axis. The 5LC6 Lift variant calls for its own communication profile and documentation. Verify safety requirements separately using the machine's design.
Angle of alignment and commissioning
Back up the exact device parameters and record the mechanical datum. Restore direction, scaling and preset under the machine commissioning procedure. Confirm stable position after restart. A machine preset and an OEM servo commutation offset are separate settings.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Exact model downloads. Use the exact variant data sheet, mechanical drawing and EDS.
- CANopen Lift comparison. Separate 5LC6 variant.