What specialist testing can show
TI-5000JX bench. Use TI-5905 for the verified 12-contact M23 branch. Check the specified excitation and return signals on the correct TI-5000JX resolver setup.
TI-3000JX motor run. Confirm the actual AM2 frame, fixture and commutation reference before a run test.
Starting lead. TI-5905 for the documented 12-contact M23 resolver connection.
Beckhoff AM2 Single-Speed Resolver Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AM2 single-speed resolver | Standard AM2 feedback according to Mitchell. Confirm the fitted resolver and 12-contact M23 branch. |
| AM227–AM297 | Range covered by the Beckhoff installation and wiring manual. Match the exact model in the outline and resolver drawings. |
| AM2 with ECN or EQN | Optional EnDat builds in Mitchell’s AM2 reference. Their documented connection and test method differ. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback principle | Passive single-speed resolver. One electrical resolver cycle per mechanical turn. |
| Documented fixture | TI-5905 on the Mitchell 12-contact M23 resolver branch. |
| OEM wiring reference | Beckhoff AM227–AM297 manual, resolver wiring diagram. Use the fitted motor and amplifier combination. |
Interface and measuring method
The drive sends an AC excitation and measures sine and cosine returns. It calculates angle from the two return signals. If both returns disappear, check the excitation and harness first. A good resistance measurement alone does not establish correct phase or amplitude.
Mounting and fit
Use the exact Beckhoff motor outline for frame and shaft fit. Preserve the resolver’s rotor location and stator alignment before opening the rear assembly. Confirm the fastening and position reference from the actual motor service instructions.
Wiring and connector scope
Use the Beckhoff resolver wiring diagram for excitation, sine and cosine pairs. Match the contact orientation to the actual M23 connector and verify the thermistor and shield separately. Do not reuse the 17-contact EnDat diagram.
Internal motor and machine cables
TI-5905 is the test lead for the documented AM2 resolver plug. Find the Beckhoff motor-to-drive cable in the matching AM2 and amplifier documentation. Source any internal resolver lead from the exact motor order.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Both return signals missing | Confirm excitation at the approved breakout and check the disconnected harness before diagnosing both windings. |
| Angle is unstable in one portion of a turn | Check each return pair separately and verify mechanical seating and cable condition. |
| Angle reads but the drive will not commutate | Verify feedback mode, resolver polarity, phase reference and the actual motor data. |
Angle of alignment and commissioning
Capture the original phase reference, resolver direction and motor configuration. A specialist should confirm the resolver’s phase and electrical alignment on the approved fixture before powered operation.
Motor and drive applications
Beckhoff AM2, with AM227–AM297 manual as the motor reference
Record the full AM2 order, fitted wiring view and exact resolver excitation and internal harness.
Related SpareFaber guides
Drawings, pin maps and manuals
- Beckhoff AM Series Motors. Common Cables and Motor Model Designation, AM2
- Beckhoff AM227–AM297 synchronous servomotor manual. AM2 resolver diagram in the Installation chapter and model-specific motor dimensions.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.