Identify the fitted part
| Guide scope | Bosch Rexroth MAD / MAF M0 / S0 I2C — Motor application |
|---|---|
| Feedback identity | Record the fitted feedback maker and complete designation; the named motor family is not a sensor part number. |
| Manufacturer MPN / full suffix | MAD / MAF M0 / S0 I2C is the scoped family/designation. Match every additional character on the fitted label before ordering. |
| OEM service ID / motor order | Not established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately. |
| Interface | Indramat OEM digital I2C |
| Documented starting connection | TI-5021 plus TI-5104; direct TI-5076 plus module |
| Material distinction | TCG200 covers M2/S2 EnDat; TCG316 covers C0 incremental. Protocol and memory handling differ. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Check OEM digital position/status and spindle memory using the fitted encoder ID; do not apply a servo-memory template. |
|---|---|
| Starting lead / fixture | TI-5021 plus TI-5104; direct TI-5076 plus module |
| Profile / module | Indramat OEM digital spindle selection; TI-5104 with the documented path. |
| TI-3000JX motor-run scope | Bench feedback scope. No TI-3000JX run claim for the asynchronous spindle application; MAD/MAF is explicitly excluded by Mitchell. |
The admission evidence is Rexroth MAD & MAF Asynchronous Motors — Encoders table and Image 3, I2C Encoder Option (M0/S0). Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
Current production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement.
Specifications and interface
| Verified technical boundary | Identify M0/S0 and the legacy digital-memory path; keep these asynchronous motors outside TI-3000JX run testing. |
|---|---|
| Supply / output compatibility | Use the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide. |
| Exact dimensions, torque and pins | Use the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted. |
This guide covers the legacy Indramat I2C encoder-memory arrangement on M0/S0 motors. It is not a generic bare I2C electronics connection. Use the documented TI-5021/TI-5104 or direct TI-5076 path and preserve incoming identity and memory.
Mechanical fit and retention
Photograph the incoming shaft/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.
MAD is air-cooled and MAF is liquid-cooled. The M0/S0 drawing is the legacy I2C branch, not C0 incremental or M2/S2 EnDat. Mitchell explicitly excludes these asynchronous motors from TI-3000JX running and does not require synchronous commutation alignment for them.
Wiring and connector boundaries
Map five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.
Starting connection for this guide: TI-5021 plus TI-5104; direct TI-5076 plus module. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
No internal OEM harness number or universal extension has been verified for this exact fitted order. Obtain the motor assembly drawing and photograph both loom ends before sourcing it. A fixed installation cable and a cable-carrier extension may have different flex and shielding requirements. Do not convert the Mitchell test-lead number into an OEM replacement part number.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Configuration-specific check | MAD is air-cooled and MAF is liquid-cooled. The M0/S0 drawing is the legacy I2C branch, not C0 incremental or M2/S2 EnDat. Mitchell explicitly excludes these asynchronous motors from TI-3000JX running and does not require synchronous commutation alignment for them. |
|---|---|
| Fault appears when the machine cable moves | With the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds. |
| No feedback or intermittent loss at the drive | After label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell. |
| Position reads but status or retained reference is wrong | Save detected identity, status and incoming position. Check the documented profile and retention arrangement before a reset, battery intervention or data transfer. |
Alignment, reference and memory
Mitchell states that these asynchronous spindle motors do not require feedback commutation alignment and cannot be run on TI-3000JX. Preserve the machine reference, direction, fitted encoder identity and motor data. Do not apply synchronous motor alignment angles or generic memory images.
Motor and drive applications
MAD / MAF M0 / S0 I2C. TCG200 covers M2/S2 EnDat; TCG316 covers C0 incremental. Protocol and memory handling differ.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Rexroth MAD & MAF Asynchronous Motors — Encoders table and Image 3, I2C Encoder Option (M0/S0)
Exact OEM technical PDF remains to obtain. The Mitchell reference establishes only the documented device or motor/feedback connection; it does not fill missing ratings or pins.
Common questions
What should accompany a MAD / MAF M0 / S0 I2C enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
Bench feedback scope. No TI-3000JX run claim for the asynchronous spindle application; MAD/MAF is explicitly excluded by Mitchell. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation