Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use the documented host circuit or manufacturer evaluation arrangement to observe SSI, PWM or the configured outputs and compare them to known angles. Mitchell motor-feedback support for this bare IC is unconfirmed. Select a board-level fixture with the correct logic and supply.
Broadcom AEAT-8800-Q24 Magnetic Encoder IC technical reference
Find your part number
Use the full label and suffix. The main reference is AEAT-8800-Q24. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AEAT-8800-Q24 | 5 × 5 mm QFN-24 board-level device with an exposed ground pad. | Configurable absolute SSI/PWM and incremental or commutation outputs. |
| AEAT-8000 family | Related magnetic sensing products. Confirm complete package and marking. | Compare electrical mode, pinout and programming from the exact datasheet. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Absolute output | Programmable 10 to 16-bit absolute resolution, depending on mode and configuration. |
| Other outputs | Configurable ABI and UVW options. Pin 24 can be W or PWM according to mode. |
| Recommended operating supply | 3.0–3.6 V in 3.3 V operation or 4.5–5.5 V in 5 V operation. Confirm board configuration and datasheet conditions. |
| Fit | QFN-24, nominal 5 × 5 mm. Magnet geometry and spacing come from the Broadcom application diagram and the host assembly. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
The chip is soldered to the host PCB. Its Hall system reads a rotating magnet centered and aligned to the package. Check the board mounting and magnet position for eccentricity, tilt or movement. Follow the Broadcom placement drawing and the equipment OEM for assembly tolerances and soldering.
Interface and measuring method
The chip converts magnetic angle into a digital word. In SSI mode the host clocks a position read. The board may instead use PWM or selected incremental or commutation outputs. Determine which mode and logic level the board uses. A wrong mode can look like a bad sensor even when the magnet and supply are healthy.
Verified wiring
Follow the package pin-1 and exposed-pad view in the datasheet. These are IC contacts. Use the host board’s schematic for external connectors and do not assign a standard motor connector from these numbers.
| Contact or group | Function |
|---|---|
| 14 and 19 | VDDA supply inputs |
| 13, 20 and exposed pad 25 | VSS ground |
| 10 / 11 / 12 | Clock / SSI NSL or SPI input / data output |
| 21 | SSI/SPI selection |
| 7 / 8 / 9 | I / B / A in ABI mode |
| 22 / 23 / 24 | U / V / W in UVW mode. 24 can serve PWM. |
Cables inside the motor and at the machine
The host PCB sets the connection to the outside machine. Use the board drawing to trace power, reference and selected signal lines to any local connector. Get the actual motor or machine harness number from the assembly label. An industrial SSI cable assumes the board provides a matching interface.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Board inspection. Keep the host board de-energized and observe ESD controls. Inspect the package, connector and magnet before probing, and use the board schematic to identify test points.
| Observation | What to verify |
|---|---|
| Angle is noisy once per revolution | Check magnet centering, gap and board movement with the approved setup. |
| Host sees no SSI data | Verify configured supply, host clock and select, mode and routing to the correct output pin. |
| Replacement board has a consistent angular offset | Verify the installed magnet orientation and read original configuration with the OEM-approved method. |
Powered checks. A qualified technician can use the approved host-board test setup to verify the configured supply, logic signals and magnet response. Isolate the board before changing connections.
Motor and drive applications
This part is an IC for the documented host-board circuit. Match the actual PCB part and revision, magnet and configured logic interface. Repair or replacement at board level needs the OEM’s calibration and configuration information.
Angle of alignment and commissioning
Check the magnet center and mechanical zero before changing electronic settings. Record available original configuration using the approved board process. OTP settings require the manufacturer’s specific programming conditions and should be handled by a qualified technician after confirming the intended values.
Drawings, pin maps and manuals
- Main technical PDF. Broadcom exact part datasheet. Pin assignment, electrical conditions, magnet placement and interface configuration.
- Manufacturer reference. Match the exact order code or the identified motor option.