Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Check LED current and the detector rail separately. Use a scope and the specified load to check A/B at controlled motion. Inspect the ESD-sensitive package and scale before substituting the sensor.
Broadcom AEDR-8300-1Q2 Reflective Optical Incremental Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is AEDR-8300-1Q2. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AEDR-8300-1Q2 | Amber 180 LPI two-channel reflective surface-mount version. The packaging digit refers to order quantity. | Digital incremental A and B outputs with separate detector supply and LED feed. |
| AEDR-8300 K and P variants | K uses 75 LPI and P uses 150 LPI. Their code scales differ. | Two-channel versions. Match optical pitch before substitution. |
| AEDR-8310 series | Check the exact package and scale pitch. | Single channel. Pin 1 has no connection on the documented K/V versions. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Reflective pitch | 180 LPI, approximately 7.09 lines/mm. Check codewheel effective radius or code strip pitch. |
| Operating gap | 1.0–2.5 mm, nominal 2.0 mm, using the package and scale reference planes from the drawing. |
| Detector supply | 4.5–5.5 V, 5 V nominal. Apply the datasheet ripple, output load and LED conditions. |
| LED and speed | 13–18 mA LED current, typically 15 mA. The Q family has a 30 kHz specified count frequency limit. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The surface-mount sensor looks at a moving reflective pattern on a wheel or strip. Use the PCB land pattern, orientation mark and optical centre in the drawing. Measure the gap across travel and look for runout, tilt and contaminated or damaged tracks.
Interface and measuring method
The emitter illuminates the scale. Alternating bright and dark regions create A/B pulses. The phase relationship gives direction. Rotation produces the count for the specific wheel pattern, so 180 LPI alone does not establish pulses per revolution.
Verified wiring
| Pad | Signal |
|---|---|
| 1 / 5 | Channel B / channel A |
| 2 / 4 | Ground |
| 3 / 6 | VLED through the specified current limit / detector VCC |
Use the top view in the datasheet to find pad 1. The published 5 V reference circuit uses 220 Ω in series to VLED. Inspect the actual circuit and resistor, since VLED is the LED feed. Probe the two channels with the approved load and ground reference.
Cables inside the motor and at the machine
This is a PCB component without a standard external encoder harness. Trace the device pads to the host board connector and use that equipment's schematic. Confirm a cable map from the complete assembly before connecting a remote counter or supply.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Both channels stay fixed | Check detector rail, LED current path, scale reflectivity, pitch and gap. |
| Only one channel is missing | Check its pad, solder joint, output loading and continuity to the board receiver. |
| Counts drop at a repeatable position | Check local track contamination, eccentricity and gap through a full turn. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use with a reflective scale built for the same line density. A transmissive encoder and codewheel use a different optical path. Verify the original assembly's scale geometry and PCB before replacing the sensor.
Angle of alignment and commissioning
Restore the documented optical centre, scale alignment and clearance. Confirm channel order and homing through the machine procedure after board work.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Broadcom technical PDF. See operating conditions, pin configuration, scale geometry, LED circuit and ordering key.
- Exact 1Q2 product record. Verify the resolution, package option and exact device code.