Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A compatible SSI receiver or scope can check frame timing and count repeatability with the correct mount, cable and supply. Record validity before adjusting mechanics. Confirm exact Mitchell profile and adapter compatibility if considering that equipment.
Celera Motion IncOder INC-3-075 SSI1 Inductive Ring Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is INC-3-075-181001-SSI1-AC1-12-AN. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| INC-3-075-181001-SSI1-AC1-12-AN | 75 mm screw-mount rotor and stator, hard-anodized. AC1 axial connection. | 18-bit resolution, SSI1, nominal 12 V option. |
| INC-4-90-191001-ASI1-RFC1-24-AN | Published 90 mm servo-clamp example with radial flex connection. | Separate asynchronous serial and 24 V configuration. Verify the actual label. |
| SSI2 configuration | Select the mechanical and supply options separately. | SSI2 frame differs from SSI1. Check the receiver frame definition. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Order code | INC-3 screw mount, 075 diameter, 18-bit reference configuration, SSI1, AC1, 12 V, AN finish. |
| Position | 18-bit singleturn value in the documented SSI1 frame. Use its validity and status bits. |
| Installation | Set rotor/stator spacing and alignment per the 75 mm screw-mount drawing. Match the exact mechanical option. |
| Electrical | Differential RS-422 clock input and data output. The reference example selects the 12 V supply option. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The shaft turns the ring rotor while the stator remains fixed to the machine. Use the 75 mm screw-mount drawing for the pilot, fasteners and allowable rotor-to-stator geometry. Check axial movement at the extremes of service travel. Confirm the assembly has clearance and the cable is supported before rotating.
Interface and measuring method
The receiver initiates each SSI read with differential clock pulses. SSI1 sends a binary position field with status in a 24-bit frame. The 18-bit device fills the applicable position bits. The receiver must check position validity and use the proper field and frame length before applying machine scale or offset.
Verified wiring
The table identifies contacts for the documented SSI1-compatible INC-CAB3 cable in section 9.1. Use the AC1 connector face drawing before terminating a lead.
| Function | Connector contact |
|---|---|
| Supply / return | 10 / 9 |
| Data A / B | 5 / 7 |
| Clock A / B | 8 / 6 |
| Zero controls | Use section 7.1 for the exact reset and set circuit. Keep the factory state during diagnosis. |
Several wires are black in the factory cable. Identify them by their pair and verified continuity. Use the 12 V option's documented supply limits and the specified shielding and termination.
Cables inside the motor and at the machine
INC-CAB3-2, INC-CAB3-5 and INC-CAB3-10 are the 2, 5 and 10 m standard 8-way cable options in the product guide. The manufacturer lists separate HT variants. Confirm the installed connector, receiver end and temperature conditions.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No valid position | Confirm clock and data pairs, the exact power option and SSI1 frame settings. |
| Validity drops at one shaft angle | Check concentricity and rotor/stator spacing across a full controlled turn. |
| Smooth count but wrong engineering angle | Verify scaling, zero offset and SSI1 position field before moving the rotor. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on machine axes with a compatible SSI receiver. Confirm the installed ring dimensions, drive input and machine-reference method. The documented example identifies a valid configuration. Verify orderability for the exact code.
Angle of alignment and commissioning
Set mechanical alignment using the matching drawing. Record the original SSI direction and zero before replacing parts. If a zero command is required, follow the manufacturer and machine procedure and verify the reported angle across motion.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Mounting and connection reference. Use the 75 mm drawing, SSI1 in section 6.4, AC1 in section 7.1, and cables in section 9.1.