Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell documents limited direct coder testing. Use the corresponding drive for the SLM3 output.
TI-3000JX motor run. Exact motor run setup open
Control Techniques CT-Coder + SLM3 SL Motor Feedback technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| CT-Coder 3 | One of the revisions Mitchell documents. Check the fitted label and supply requirements. |
| CT-Coder 4 | Another documented revision. Match the internal coder connection separately. |
| SLM3 | Intermediate electronics board inside the SL motor feedback cover. |
Production and end-of-life status
Mitchell identifies the SL motor line as obsolete. Check the original coder and board revision before seeking parts or a migration.
Specifications
| Parameter | Verified scope |
|---|---|
| Coder signal | Incremental with sin/cos commutation in Mitchell’s description. |
| Motor-side path | SLM3 board to a 5-pin circular motor feedback connector. |
| Bench scope | Limited direct CT-Coder support using TI-5724. Verify the exact revision and the documented supply arrangement. |
Mounting and fit
Record the full SL motor order and the CT-Coder revision. Photograph the rear cover, board and loom orientation before opening. Confirm the mounting and feedthrough using the motor service drawing.
Interface and measuring method
The CT-Coder and SLM3 are two stages in the feedback path. The motor bulkhead carries the board’s output. A valid direct coder reading can coexist with a fault in the board or downstream connection.
Wiring and connector scope
Use the Mitchell TI-5724 memo for the supported direct encoder setup. The coder uses multiple supplies on the documented revisions, so verify the label and exact wiring before connecting a fixture. Use the compatible drive to evaluate the SLM3 path.
Cables inside the motor and at the machine
TI-5724 connects at the coder and bypasses the SLM3 electronics. Trace the internal loom and the motor’s 5-pin bulkhead separately. The motor-side OEM harness is not interchangeable with the direct test lead.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Direct coder reads but motor feedback fails | Check the internal connection, SLM3 and compatible drive connection as a separate stage. |
| Coder fails with a common encoder adapter | Confirm the exact CT-Coder version and specified multi-supply setup. |
| Fault appears after moving the rear cover | Check the isolated internal loom and board connector seating. |
Motor and drive applications
Control Techniques SL motor family Check the exact ID, drive and connector before applying an installation or test procedure.
Isolate the coder, SLM3 board and outer connector. Confirm the revision and labeled supply requirements.
Angle of alignment and commissioning
Capture the original coder reference, motor direction and the fitted revision before disassembly. Recheck the complete feedback chain through the supported drive setup after mechanical work.
Drawings, pin maps and manuals
- Control Techniques SL guide. Article body. Coder revisions, TI-5724 and the SLM3 board boundary.
- Mitchell TI-5724 technical memo. Linked by the Mitchell SL article for the direct CT-Coder setup.