Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified fixture test can verify differential channels, relative phasing, index and counts for one known turn with the documented load. Use the installed harness and a separate receiver check to distinguish a connector fault. Exact Mitchell compatibility remains unverified.
Dynapar HS35R102481P7 Differential Hollow-Shaft Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is HS35R102481P7. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| HS35R102481P7 | 5/8 in insulated through bore, 4.5 in C-face tether, 10-pin MS connector with mate. | 1,024 PPR. P is the extended-temperature option for differential ABZ, 5–26 V input and output. |
| HS35R10248147 | Same bore and tether codes. 10-pin connector with mate. | Output code 4 has differential AB only. Verify whether the machine uses Z. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Order-code groups | HS35R / 1024 / 8 / 1 / P / 7. Datasheet ordering information, page 2. |
| Shaft / tether | 5/8 in (15.875 mm) insulated bore. 4.5 in C-face tether. |
| Power / outputs | 5–26 V DC supply. P-code 7272 differential A/B/Z with output voltage following the documented supply range. |
| Pulse response | Datasheet 702761-2 U specifies 200 kHz data and index response. Check serial-revision limits with Dynapar. |
| Speed / sealing | 6,000 rpm maximum in the series data. The enclosure rating falls to IP64 above 5,000 rpm. Apply the other installation deratings. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Clean and measure the mating shaft, compare insertion length and use the 5/8 in isolating insert. Follow the clamp and tether sequence in the installation manual. Keep the tether free to accommodate the documented shaft movement and prevent housing rotation. Check that the clamp and tether suit the installed C-face.
Interface and measuring method
The optical incremental channels provide differential A and B for count and direction, and Z for index. The P output can follow the 5–26 V supply range. Confirm receiver voltage and termination before applying supply. A low-voltage differential input may require a different output option.
Verified wiring
Use Table 1 of the HS35R datasheet, 10-pin differential line driver with index column. This is the MS lettered contact assignment. Read the face markings on the connector and compare with the mating socket view.
| Function | Contact |
|---|---|
| A+ / A− | A / H |
| B+ / B− | B / I |
| Z+ / Z− | C / J |
| Supply / common | D / F |
| Case / unused | G / E (N/C) |
Cables inside the motor and at the machine
The datasheet accessories table lists 1400635-XXXX for the 10-pin differential-with-index cable and 109209-XXXX for the NEMA 4 option. It also identifies the MS3106A-18-1S mating style as MCN-N6. The connector table header spells the first cable differently. Use the accessories section and confirm the complete order code and length with Dynapar before buying.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No output at receiver | Check D/F supply, connector lettering and the receiver's allowed voltage. Check that the shaft actually rotates the encoder. |
| Counts jump with load or vibration | Check clamp and tether condition, cable strain, shield and differential pairs at each end. |
| Index missing | Verify P/7 on the tag and C/J continuity. Compare the index signal with the controller input during a controlled turn. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on compatible heavy-duty motor or machine shafts with differential pulse receivers. Compare the exact flange or tether, insert diameter, speed, environment and receiver input before replacement.
Angle of alignment and commissioning
Centre and retain the encoder, then establish direction and index in the machine controller. This guide covers shaft and tether installation. Motor commutation alignment depends on the motor and drive if that application uses the incremental index.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- HS35R installation manual. Use the matching mounting and safety instructions for the installed assembly.
- AB-only comparison. Manufacturer product record for HS35R10248147.
- Exact order-code corroboration. Independent listing for the exact P7 code.