What specialist testing can show
TI-5000JX bench. Use the documented direct route. Decode and preserve the original alignment with the Elau memory workflow.
TI-3000JX motor run. Integrated-drive testing is outside the documented setup. Exact direct-motor run setup open.
Starting lead. TI-5094 direct to the documented encoder Module TI-5104.
ELAU iSH SKS/SKM HIPERFACE Integrated Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| ELAU iSH | Integrated-drive motor family named by Mitchell. Record the complete module order, drive revision and fitted feedback label. |
| SKS / SKM HIPERFACE | Internal feedback family for the documented branch. Verify singleturn or multiturn and the actual connector. |
| Lexium 62 ILM | Related integrated-drive application. Use the ILM instructions and label for ILM hardware. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Classic HIPERFACE on the documented direct SKS/SKM route. |
| Direct test | TI-5094 and TI-5104 at the verified internal encoder. Mitchell excludes testing through the integrated drive section. |
| Alignment record | Mitchell describes motor-specific data stored in the encoder. Its Elau memory test is the starting point for the documented setup. |
Interface and measuring method
The internal encoder sends absolute position and analog sine/cosine to the drive through HIPERFACE. The machine link connects to the integrated drive, so a direct encoder test and a machine-network test cover different parts of the assembly.
Mounting and fit
Use the exact iSH assembly manual and type label for the motor and drive housing. Internal access is specialist work. Record the fitted encoder position, connector and internal routing before disturbing it.
Wiring and connector scope
Keep the machine-side power and communications separate from the direct encoder connector. Use the verified internal drawing and isolated test setup for the documented SKS/SKM branch.
Internal motor and machine cables
TI-5094 is a direct feedback test lead. Confirm the internal loom and external PacDrive connection by module order and connector revision before replacing either.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Machine link alarms but direct feedback reads | Check the external link, integrated drive and internal harness separately. |
| Serial response is stable but position jitters | Inspect the analog path, seating and harness on the documented fixture. |
| Fault begins after encoder replacement | Compare the fitted SKS/SKM suffix, memory and original alignment before testing motion. |
Angle of alignment and commissioning
Read and retain the original Elau memory and motor alignment record. Mitchell notes that the memory tool may report a model warning on this setup. Verify the actual file, encoder and motor before any write or reference change.
Motor and drive applications
ELAU iSH integrated-drive servo module
Separate internal encoder, harness, integrated drive and machine link faults on the iSH assembly.
Related SpareFaber guides
Drawings, pin maps and manuals
- Elau iSH motors with integrated drive. Article body. Direct testing, Elau memory and motor-specific alignment.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.