Site visit or send-in evaluation
Send the complete A06B motor order code and A860 encoder label, CNC or amplifier model, alarm number and connector photos. Record whether the fault started after a collision, cable flex, encoder replacement or a battery warning. Use the enquiry form to share the details.
What specialist testing can show
Mitchell documents TI-5000JX testing for supported FANUC serial Pulsecoders. With the correct profile and cable, check serial count and direction, alarm/status and commutation display. Its TI-3000JX run manual lists P* Alphai with the TI-5047 feedback lead. Confirm the exact motor and current software. Use a secured, guarded fixture and verify the commutation pattern and phase reference before allowing rotation. Mitchell FANUC bench testing · Mitchell αi run-test method and lead
FANUC αiA1000 A860-2000-T301 Pulsecoder technical reference
Find your part number
Read the complete A860 number and the motor’s A06B number. αiA1000 is the absolute serial type that FANUC specifies at one million divisions per revolution. Use the complete suffix to select the housing and sealing version.
| Part number | Feedback class | Order distinction |
|---|---|---|
| A860-2000-T301 | αiA1000 absolute serial, 1,000,000 divisions/rev | Standard specification for the documented A06B-02xx motor order group. |
| A860-2000-T321 | αiA1000 absolute serial, 1,000,000 divisions/rev | IP67 specification in the FANUC replacement table. |
| A860-2005-T301 | αiI1000, incremental-class serial | Same division count with different retention behavior. |
| A860-2001-T301 | αiA16000 absolute serial, 16,000,000 divisions/rev | Different resolution and controller configuration. |
Match the motor and encoder together, including the sealing variant and connector. FANUC αi ordering specifications (PDF) · FANUC Pulsecoder division counts (PDF)
Production and end-of-life status
FANUC’s maintenance manual lists T301 and T321 as replacement order numbers for the documented motors. Current production and availability for the exact A860 suffix require FANUC confirmation. Reviewed 7 November 2026. FANUC replacement part list (PDF)
Specifications
| Parameter | Value / scope |
|---|---|
| Measurement | Motor-mounted absolute serial Pulsecoder. 1,000,000 divisions per motor revolution. |
| Supply functions | The αiA1000 connector drawing identifies +5 V main power and a separate +6 V backup contact. Follow the exact amplifier and battery specification. |
| Serial connection | 10-contact JAE JN2AS10UL1-R motor receptacle in the documented αi series. |
| Mechanical connection | Oldham coupling and motor pocket with O-ring on the documented αi assembly. |
| Environmental and speed limits | Use the motor’s service and outline data. The IP67 variant is T321 in the documented list. |
FANUC B-65262EN/06 section 8.1, Pulsecoder specifications (PDF)
Mounting and fit
The Pulsecoder fits in the rear motor pocket. An Oldham coupling transfers shaft rotation to it. FANUC’s illustrated assembly uses four M4 fixing bolts and a seated O-ring. During authorized service, use the motor’s correct coupling orientation and engage the teeth before seating the housing. The adjacent cover screws are separate. Check for damaged coupling teeth, a pinched O-ring and debris in the seat. Do not force the Pulsecoder into the pocket.
FANUC lists A290-0501-V535 as the Oldham coupling for the documented A06B-02 motor group. Obtain the exact motor’s approved fastener and commissioning instructions before internal service. FANUC B-65285EN/03 sections 1.4–1.5, coupling and assembly (PDF) · FANUC αi replacement tables (PDF)
Interface and measuring method
The amplifier receives digital position and alarm information on the complementary RD pair. The αiA1000 has a separate backup circuit for absolute position retention. It is possible to have a valid serial link but lose the machine’s absolute reference after feedback or battery work. Read alarms and verify the CNC reference separately.
Verified wiring
| Connector pin(s) | Function |
|---|---|
| 8 and 9 | +5 V main supply |
| 7 and 10 | 0 V |
| 6 / 5 | RD / complementary RD |
| 3 | Frame ground |
| 4 | +6 V backup contact on the documented absolute configuration |
Use the connector view for the keyed motor receptacle and the separate amplifier diagram for the cable end. Keep unassigned contacts clear and use the OEM battery arrangement. This table does not give a universal CNC connector map. FANUC motor-side connector view and signals (PDF)
Cables inside the motor and at the machine
| Part or kit | Role |
|---|---|
| JN2DS10SL1-R | JAE straight mating plug in the αi connector list, for the documented cable diameter range. |
| JN2DS10SL2-R | JAE straight mating option for the larger cable diameter in the same list. |
| JN2FS10SL1-R / JN2FS10SL2-R | Right-angle mating options. Confirm cable diameter and clearance. |
| TI-5047 | Mitchell αi bench feedback lead. Match the tester profile and motor. |
The machine feedback cable connects the motor receptacle to the matched amplifier. Obtain the CNC or machine builder’s cable assembly number and end-to-end diagram before making a replacement. The FANUC connector kits above are components. The internal Pulsecoder assembly is ordered by the exact A860 part. FANUC αi signal connector ordering and cable drawings (PDF) · Mitchell bench lead
Fault checks
Preserve the CNC reference before disturbing the feedback. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Account for the separate absolute backup supply under the OEM procedure.
- Inspect. Check plug engagement, damaged pins, contamination, coolant ingress and cable strain. If the alarm began after a rebuild, inspect the coupling and seating under the authorized motor procedure.
- Check the isolated cable. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Verify any parallel power conductors and the separate backup route in the actual wiring diagram.
- Measure and compare. A qualified technician can use the approved breakout fitted while off to verify nominal +5 V between the documented supply and return contacts. Check backup at the OEM test point, with the specified battery arrangement. Read alarms and serial state using the FANUC system or compatible tester.
- Use the symptom. No serial data after a cable change calls for power, return and RD checks. Valid position with a lost datum calls for backup and reference checks. Faults synchronized with shaft motion after replacement call for inspecting the coupling and commissioned direction.
Motor and drive applications
FANUC documents T301 for standard αiA1000 configurations in the A06B-02aa-Bcc0 motor group and T321 for the IP67 group shown in the replacement table. The αiS 8/4000 is in the A06B-0235-Bxxx motor family. Confirm the entire motor suffix and its replacement table before applying the example. FANUC exact motor group and replacement codes (PDF) · FANUC motor ordering specifications (PDF)
Angle of alignment and commissioning
The coupling’s physical orientation, the motor commutation reference and the CNC absolute machine datum are separate checks. Preserve the incoming reference and configuration before removal. Mitchell’s documented guarded αi verification uses the +U/−V and +U/−W phase references and compares the commutation pattern. Use the exact motor and FANUC commissioning procedure for replacement and any reference return. Obtain the motor-specific procedure rather than assuming a fixed angle from T301.
Drawings, pin maps and manuals
- FANUC B-65262EN/06 αi motor descriptions (PDF). Section 8.1 for resolution and motor-side signals. Appendix on αi signal connectors for mating parts.
- FANUC B-65285EN/04 αi maintenance manual (PDF). See Pulsecoder replacement, ordering and battery instructions.
- FANUC B-65285EN/03 maintenance manual (PDF). Sections 1.4–1.5 illustrate coupling orientation and the O-ring seat.
- Mitchell FANUC run-test reference. Check the αi selection, cable and guarded verification.