Encoder and resolver technical library

Festo EMMS-AS-190-M-HS-ARB Resolver Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

Festo EMMS-AS-190-M-HS-ARB Resolver SpareFaber service card.

Festo EMMS-AS-190-M-HS-ARB — Resolver. This guide helps identify the fitted feedback, distinguish a cable or setup fault and prepare a scoped repair, installation or alignment assessment. SpareFaber accepts UAE site-service and send-in evaluation enquiries after reviewing the motor/feedback labels and fault history.

Identification · Testing scope · Fault checks · Drawings and manuals · Service enquiry

Identify the fitted configuration

Item Verified scope
Manufacturer / application Festo EMMS-AS-190-M-HS-ARB
Feedback Resolver — 2-pole resolver; exact fitted device ID unverified
OEM catalogue part number 1584939
Motor mounting 190 nominal flange
Braked representative EMMS-AS-190-M-HS-ARB
Holding brake B; 30 Nm; 24 V
SpareFaber service reference TCG1407

The service reference is not an OEM part number. Verify the complete fitted labels and connector revision before selecting a replacement or test connection.

Specialist feedback testing

TI-5000JX: EMMS-AS resolver checks via documented M23 path, after confirming excitation and motor-side pin map. No serial-memory functions apply.

Starting connection: TI-5901 M23 feedback. Power: TI-3027 M23 for size 140; TI-3048 M40 for size 190, subject to pin/key verification.

Module / software: Use the matching resolver setup; exact Athena/firmware minimum and motor-specific alignment profile were not established.

TI-3000JX motor-run scope: TI-3000JX conditional only. Match actual motor/brake rating, power connector and supported run profile; available power cable alone is not run approval.

Signals and specifications

Parameter Documented value / limit
Complete motor order EMMS-AS-190-M-HS-ARB
OEM part number 1584939
Feedback 2-pole resolver; sine/cosine analogue signals
Nominal mounting size 190 mm
Motor feedback connector M23, resolver motor-side pin map
Motor power connector M40
Holding brake B; 30 Nm; 24 V
Feedback device supplier / internal ID Not established for the fitted unit; verify the physical label

Signal periods, serial position bits, turn range and drive-scaled counts describe different quantities. Use the exact encoder option and controller configuration when comparing readings.

Mechanical fit and retention

The EMMS-AS-190-M-HS-ARB is the braked, high-voltage standard-winding resolver order identified by Festo part 1584939. The B suffix belongs to the holding-brake selection. Confirm the complete order before using the 140/190 drawings: resolver and serial-encoder rear assemblies are not identified by the flange number alone.

Use PDF pages 21–22 for shaft, pilot, fixing holes and resolver/brake dimensions. The 140 model is a nominal flange class; the drawing gives B1 as 140.5 mm. The S/L or S/M length changes the motor package and must match the available machine space. Internal resolver retention, coupling details and service torque remain specific to the fitted unit.

Wiring and connector boundaries

Festo’s PDF page 14 is explicitly the motor-side pin allocation. Confirm the connector face and pin view in the drawing before using this summary.

M23 resolver contact Signal
1 / 2 R1 exciter + / R2 exciter −
3 / 4 S1 cosine + / S3 cosine −
5 / 6 S2 sine + / S4 sine −
7–12 Not connected in the documented assignment

The resolver needs the correct AC excitation and supported tester settings; this table is not an instruction to connect a DC supply to its windings. Use the exact OEM/tester procedure. Motor power, temperature and brake contacts are separately mapped on page 14; size 190 uses M40 power while size 140 uses M23 power.

Internal, machine and test cables

TI-5901 M23 feedback. Power: TI-3027 M23 for size 140; TI-3048 M40 for size 190, subject to pin/key verification.

Match connector keying and the motor-side assignment before choosing the Mitchell lead. This test lead is not an OEM machine harness. The exact machine cable order, internal resolver loom and any replacement harness are not established by the motor part number alone; use cable labels and both-end wiring documentation.

Practical fault checks

Follow the site isolation procedure before physical checks: secure the driven load, lock out relevant energy sources, observe the drive discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short testing and account for intentional shield bonds. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure.

Observed symptom Useful next check
Resolver alarm or missing angle Check connector condition, correct excitation path and isolated cable continuity. Compare sine/cosine circuits through the exact OEM drawing before judging the resolver.
Angle changes intermittently with movement Inspect cable strain and connector retention; separate machine cable, motor bulkhead and internal resolver paths.
Motor resists motion or overheats during an attempted run Stop and verify holding-brake release and the correct motor/brake supplies under the approved procedure. A feedback pass does not prove the power or brake circuit.
Incorrect direction or phase-related fault after service Preserve the symptom and incoming references; check phase and resolver polarity conventions before any alignment change.

Alignment, offsets and memory

Record the incoming resolver position and mechanical coupling reference before removal. Confirm motor phases, polarity, direction and the drive’s referencing convention before alignment. The guide does not assign a universal electrical angle to this motor, and the listed feedback lead does not establish an automatic TI-3000JX run/alignment profile.

This selected configuration is a resolver; the EnDat memory functions and serial-only Line Levels exception discussed elsewhere for EMMS-AS do not apply to it. Do not replace it with a serial-encoder version merely because the flange matches.

Production and replacement status

The exact Festo part-number datasheet is marked for discontinuation. The source does not establish a present-day stock position, final order date or verified interchangeable successor. Keep that status separate from the ability to evaluate an existing motor’s resolver.

Motor applications and related guides

This page covers the exact braked resolver order shown above. EMMS-AS-140-MX1-RS and other EMMS-AS serial-encoder orders use a different feedback path. Compare complete motor order, drive input, brake and power connector before proposing a replacement.

Drawings and primary documents

Application evidence: F1 pp.11,14,21–22,29; F1584939 pp.1–2. F2: EMMS-AS → Resolver Technical Data and resolver M23 connector paragraph.

FAQ and service enquiry

Is this an EnDat motor?

No. This specific EMMS-AS-190-M-HS-ARB / 1584939 selection uses a resolver. Other EMMS-AS orders have serial encoders; the suffix and exact part number matter.

Can the listed lead prove the motor is ready to run?

No. TI-5901 supports the documented resolver connection. A powered motor run also needs the correct power lead, brake supply, tester limits, released profile and mechanical setup.

What should I send with a service enquiry?

Provide the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and previous repair/replacement history. Include cable labels and any OEM installation drawing. This lets SpareFaber distinguish a site investigation from a send-in feedback or motor assessment.

Request a UAE site visit or send-in evaluation. Scope, parts and turnaround are confirmed after the fitted configuration and fault are reviewed.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?