Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell distinguishes motor-connector testing from direct encoder testing.
TI-3000JX motor run. EMMS family run support is documented. Confirm exact motor, cable and setup.
Festo EMMS-AS-70-M-LS-RS 550118 EnDat22 Motor Feedback technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| EMMS-AS-70-M-LS-RS | Complete Festo motor order for this application. |
| 550118 | Festo item number. The separate HEIDENHAIN encoder ID is confirmed from the fitted unit. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Motor feedback | Absolute singleturn, inductive, 18 bit on Festo 550118. |
| Interface | EnDat22 in the Festo datasheet. |
| Mitchell connection | TI-5662 is documented for the EMMS-AS 8-pin M12 EnDat motor connection. Verify the connector on the unit. |
Mounting and fit
Use the 550118 motor drawing for the envelope, shaft and installation. Before removing an inductive encoder, record its fit and the motor nameplate. Obtain the fitted encoder’s gap and mating drawing before setting mechanical clearance.
Interface and measuring method
The drive reads absolute position from the clocked EnDat link. Mitchell notes that the motor’s serial-only arrangement does not route incremental signals. A missing analog line-level reading is expected on that connection.
Wiring and connector scope
Confirm the fitted 8-pin M12 connector and use Mitchell’s Festo connector figure with the OEM drawing. Verify clock, data, supply and shield as separate functions. The direct encoder plug uses its own diagram.
Cables inside the motor and at the machine
TI-5662 is a tester lead for the verified motor connector. Mitchell also documents direct encoder options for some EMMS-AS builds. Identify the internal loom by the exact motor and encoder labels.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Position link missing | Compare the motor connector variant and approved clock/data path before removing the encoder. |
| EnDat reads but Line Levels does not | Check that the fitted connector is serial-only. Use the approved mounting check for this encoder. |
| Motor fault starts after bearing or encoder work | Recheck gap, rotor seating, stored alignment and commissioning as separate steps. |
Motor and drive applications
EMMS-AS-70-M-LS-RS (550118) Check the exact ID, drive and connector before applying an installation or test procedure.
Verify the motor-side link and fitted encoder label. Keep the 550118 application separate from the ECI 1118 device guide.
Angle of alignment and commissioning
Capture incoming alignment and any readable motor-specific encoder data before removal. Use Festo’s approved gap and alignment procedure. Position response on EnDat alone does not establish mounting clearance or correct commutation.
Drawings, pin maps and manuals
- Festo EMMx-AS guide. EMMS-AS and Connectors. EnDat feedback options and TI-5662 scope.
- Mitchell EMMS run support. Additional application or test reference.
- Festo item 550118 technical datasheet. Festo lists the exact motor order, EnDat22, inductive principle and 18-bit singleturn feedback.