What specialist testing can show
TI-5000JX bench. Separate excitation, sine/cosine returns and the motor-to-drive harness on the matching setup.
TI-3000JX motor run. Confirm the fitted motor parameters, phase reference and supported resolver run setup.
Starting lead. Match the KSY-E connector and exact R4 drawing to a verified resolver fixture.
Georgii Kobold KSY-E R4 Stainless Servo Motor Resolver technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| KSY-E R4 | Stainless KSY-E motor with the standard resolver. |
| KSY 162.xx E-Mx-R4/xxx | One OEM drawing family. Confirm the motor length, brake field and voltage suffix on the nameplate. |
| KSY-E Rx option | Other encoder options share the stainless motor family. Use the fitted rotor-position code and correct connection drawing. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Rotor position sensor | Passive R4 resolver in the KSY-E type code. |
| Connection circuits | Excitation and sine/cosine return paths. Read the matching KSY-E connection chart for pin numbering. |
| Fitted dimensions | Frame-specific CAD and drawing files are indexed by length and brake configuration on the OEM page. |
Interface and measuring method
The resolver modulates its AC reference into two position-related winding voltages. Compare the two return paths and their reference. The winding signal and the drive’s angle conversion can be diagnosed separately.
Mounting and fit
Use the exact KSY-E frame drawing and record the incoming resolver orientation. Protect sealing and mating surfaces on the stainless motor. Check the OEM assembly procedure before opening a hygienic installation.
Wiring and connector scope
Use the KSY-E R4 connection diagram in Mitchell’s article and the OEM catalogue. Identify the excitation, sine and cosine windings with the stated connector view. Keep brake, temperature and motor power circuits separate.
Internal motor and machine cables
Match the stainless motor’s rear connection and the drive’s resolver input. Photograph the fitted gland or plug and harness routing. A screened resolver cable must retain the documented winding pair and shield arrangement.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Angle missing at all positions | Verify excitation and continuity of the correct isolated reference path. |
| One return channel weak | Check the corresponding winding pair and both mating contacts. |
| Fault after washdown or rear-end work | Inspect seals and connectors under isolation, then compare the incoming alignment and cable route. |
Angle of alignment and commissioning
Record the incoming resolver electrical angle and motor pole count before disassembly. Confirm the correct frame and direction convention with the applicable Georgii Kobold procedure before alignment work.
Motor and drive applications
Georgii Kobold KSY-E stainless servo motor
Identify the R4 option in the stainless motor order and obtain its own connection and mechanical drawings.
Related SpareFaber guides
Drawings, pin maps and manuals
- Georgii Kobold Motors. KSY-E Type Code attachment, rotor position encoder R4 row
- Georgii Kobold KSY-E frame and resolver reference. Supplementary reference for the stated model or setup.
- Mitchell KSY-E type-code chart. Reference for the fitted feedback or motor option.
- Georgii Kobold KSY-E / KSA-E catalogue. Stainless motor type codes, R4 option, dimensions and connector sections.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.