Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a manufacturer-supported EnDat/ATS setup for identity, diagnostics and mounting quality. The exact 1164809-05 Mitchell fixture, firmware and TI-5000JX profile need confirmation. A TI-3000JX motor run requires a separate exact motor and setup check.
HEIDENHAIN ECI 1119 1164809-05 EnDat Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 1164809-05. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 1164809-05 | 82A Ø6 mm blind hollow shaft, axial clamping. | ECI 1119 single-turn EnDat22. |
| 1164809-55 | 82A shaft. Check ID footnote and ordering revision. | ECI 1119 single-turn alternative ID. Confirm safety applicability and configuration. |
| 1164811-05 / 1164811-55 | 82A variants of the EQI 1131 model. | Multiturn position. Check motor and drive suitability independently. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position per turn | 524,288 positions (19 bits) for this single-turn ECI 1119. |
| Interface | EnDat 2.2 with EnDat22 ordering designation. |
| Supply at encoder | 3.6 to 14 V DC per product information 1359122. |
| Fit | 82A blind Ø6 mm bore, axial clamping. Nominal 2 mm mounting clearance for the ATS mounting check. |
| Connection | 15-pin PCB including a separate external temperature sensor path. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the 82A mating drawing to check the motor journal, locating face and axial clamp. The measured clearance is a mounting check and belongs to the illustrated stack-up. Measure where the drawing shows it and confirm with the ATS mounting function when the approved setup is available.
Inspect the locating surfaces and fastening points on the isolated assembly. A small axial shift or tilt changes the scanning gap. Use the OEM instructions for clamping and the permitted assembly tolerances, especially in a safety-related installation.
Interface and measuring method
The drive clocks each EnDat transaction and reads absolute position and diagnostic data from the encoder. ECI 1119 reports position within one turn. The EQI version adds turn information. A drive can read the ID yet still report position quality or fit errors, so inspect the diagnostics alongside the mechanical mounting check.
Verified wiring
Use the HEIDENHAIN connector illustration to orient the plug. Read the complement markings from that illustration and table. An M12 bulkhead has different numbering.
| Contact or group | Function |
|---|---|
| 13 / 11 | UP / 0 V |
| 14 / 12 | Sense UP / sense 0 V |
| 7 and 8 | DATA pair |
| 9 and 10 | CLOCK pair |
| 5 / 6 | External sensor T+ / T− |
Cables inside the motor and at the machine
The official product information shows both the encoder-side PCB and the eight-pin M12 flange connection. Use those as distinct drawing views. Look up the exact assembly in the HEIDENHAIN cable catalogue or the motor OEM parts list using the actual connector, lead length and sensor option. The motor-specific loom number remains open.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No EnDat reply | Check the supply under load and clock/data continuity in the isolated harness. Check connector viewing side and drive feedback setting. |
| Intermittent quality error over the same part of a turn | Inspect the mating journal and locating face. Compare clearance and ATS mounting values. |
| Position wraps at a turn after a replacement | Confirm the single-turn ECI versus multiturn EQI requirement and machine referencing method. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This is motor-integrated feedback. Pair the exact ECI label with the motor order and drive EnDat22 input. A related ECI or EQI in a motor with a similar housing can have a different shaft, coupling or position format.
Check the separate preceding-generation model by its ID. ECI 1118 technical guide.
Angle of alignment and commissioning
Set and verify the mechanical fit first. Follow the motor OEM to record and restore any approved commutation or machine-reference data. Use HEIDENHAIN diagnostic functions for mounting quality and the drive commissioning procedure for the installed axis. Safety-related feedback replacement requires the machine’s approved validation.
Drawings, pin maps and manuals
- Main technical PDF. HEIDENHAIN 1359122-00-B-02. Technical table, 82A mounting drawing and PCB/M12 pin layout.
- HEIDENHAIN cables and connectors. Use the exact encoder and motor outlet to choose a mating loom.