Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A documented EnDat receiver can check serial response and position repeatability. Qualified scope checks can compare A and B with a suitable load. Confirm the exact Mitchell profile, breakout and motor-running support separately before connecting a tester.
HEIDENHAIN EQN 1325 827039-04 EnDat01 Multiturn Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 827039-04. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 827039-04 | 65B 1:10 taper with 9.25 mm functional diameter. Type 06 expanding ring for 65 mm mating diameter. | 8192 positions/turn, 4096 turns, EnDat01, 512-line 1 Vpp. |
| 827039-03 | Same listed 65B taper. Type 07B coupling on the exact-ID record. | EnDat01. Verify the full mounting drawing and electrical record. |
| 823901-52 | Listed without stator coupling. Check the actual motor attachment. | EnDat01, 8192 positions/turn. Match the mating lead and mechanical parts. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Absolute position | 8192 binary positions per revolution and 4096 distinguishable revolutions. |
| Incremental output | 512 lines, approximately 1 Vpp. The exact record lists a 130 kHz −3 dB cutoff. |
| Electrical | 3.6–14 V DC, straight locking 12-contact double-row PCB connector. Use the fitted drive and loom documentation. |
| Mechanical | 65B taper, 1:10, functional Ø9.25 mm, stator coupling 06 for 65 mm mating diameter. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The 9.25 mm value describes a reference diameter on the taper. Compare the cone and engagement drawing before choosing a replacement. The centre screw retains the rotor and the 06 expanding ring restrains the encoder housing. With the motor secured and isolated, inspect the seating surfaces, retention and cable clearance. Obtain the exact fastener and tightening instructions before disturbing the fit.
Interface and measuring method
EnDat01 gives the drive a binary absolute position and turn count over a clocked serial link. The separate A/B sine and cosine tracks provide incremental motion information. A working serial position can coexist with a missing or distorted incremental track. Verify each path using the receiver's documentation and exact resolution.
Verified wiring
The exact ID record calls up D323746-00-B-01 for the 78/62S12 connector. The following reference contacts are on the encoder PCB. Use the full drawing for the view, remaining contact and supply-sense arrangement.
| Function | Contacts |
|---|---|
| Supply and return | 6a (+UP) and 3a (0 V) |
| A+ and A− | 5b and 4a |
| B+ and B− | 3b and 6b |
| Data and inverse Data | 1a and 2b |
| Clock | 5a. Confirm inverse Clock and sense routing on the complete drawing. |
The indexed layout also identifies 1b for the 0 V sense line and 2a for the supply/sense arrangement. Read the full connection drawing before making a powered breakout. Identify any motor bulkhead wiring separately.
Cables inside the motor and at the machine
Use the motor order and connector drawing to obtain the internal 12-contact loom and motor bulkhead assignment. Check whether the lead exits axially or radially and preserve its strain relief. Obtain the full loom number from the motor manufacturer when the fitted cable label is unavailable.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Serial position unavailable | Check documented supply at the receiver and feedback connection, then isolate the clock and data paths. |
| Absolute position reads but motion feedback is noisy | Check A and B pairs, shield routing and the incremental receiver. |
| Fault follows work on the motor | Check taper seating, centre screw, coupling type and reference or commutation setup. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Match the exact encoder ID, motor order and drive. The 04, 03 and 823901-52 records are useful comparisons when the encoder label looks similar. Read the machine records for mounting and reference before selecting a replacement.
Angle of alignment and commissioning
The motor procedure governs the commutation reference. Record the original direction, parameters and any encoder-stored values the OEM allows you to read. Use the same motor and a verified compatible encoder when restoring data, then verify alignment under the approved commissioning sequence.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- D323746-00-B-01 connector layout. The indexed exact reference establishes several contact functions. Obtain the complete drawing through HEIDENHAIN when the download redirects.
- 374033-09-B-01 mating drawing. Referenced by the exact-ID record. Use the support route if the download is under maintenance.
- Related ID 827039-03. Type 07B stator coupling.
- Related ID 823901-52. Variant listed without coupling.