What specialist testing can show
TI-5000JX bench. Confirm supply, clock/data, data format and singleturn or multiturn option before checking position.
TI-3000JX motor run. Specific motor-run setup remains open.
Starting lead. Match the full SSI order code and actual connector to an approved fixture.
Hengstler AC58 SSI Absolute Rotary Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AC58 SSI Gray or binary | Identify the exact SSI format and bit count using the manufacturer order table. |
| Singleturn or multiturn AC58 SSI | The order selects the within-turn resolution and any turn field. Compare the complete word with the controller configuration. |
| AC58 BiSS or parallel | Separate feedback selections. The parallel model’s pinout and controller input map differ. |
Production and end-of-life status
Hengstler provides an AC58 family catalogue and technical data. Verify the exact SSI order’s availability and connection options before replacement.
Specifications
| Parameter | Verified scope |
|---|---|
| Family size | AC58 family has a compact 50 mm catalogue length. Shaft, flange and mating dimensions vary by order. |
| Supply selection | The SSI/BiSS sheet includes 5 V and 10–30 V variants. Match the order before applying power. |
| Connection variants | The sheet shows 8-contact M12, 12-contact M23 and cable configurations. Clock and data are differential circuits. |
Interface and measuring method
The controller sends clock pulses and the encoder shifts out the position word. Check Gray versus binary, word length and any turn field. Those settings can cause position jumps even when supply and differential signaling are healthy.
Mounting and fit
Check the drawing for the actual shaft and flange, centering diameter, coupling size and mounting clearance. On a hollow-shaft variant, verify the torque support and mating shaft fit. Avoid axial load on the encoder when moving the coupling.
Wiring and connector scope
Use the SSI row for the exact connection code. The 12-contact M23 variants include both clockwise and counterclockwise contact arrangements. Confirm the connector view, clock and data polarity, preset, direction and supply from the order drawing.
Internal motor and machine cables
The data sheet lists M23 mating connectors 3 539 202 and 3 539 229 for different contact arrangements. Confirm the C/D or G/H connection branch and view before ordering. Match clock and data pairs through the extension.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Word present but position jumps | Check Gray versus binary and the configured word length. |
| No word or intermittent reply | Check the matching supply and the differential clock/data paths at the correct connector. |
| Position is smooth with a fixed shift | Compare the reference, preset and coupling seating before adjusting the controller. |
Angle of alignment and commissioning
Record the axis reference, direction input and preset state before replacement. Check a known position and measured travel after installation. Use the machine procedure for any electronic preset.
Motor and drive applications
Industrial AC58 SSI application
Separate the SSI order and clock/data wiring from the previously covered parallel AC58.
Related SpareFaber guides
Drawings, pin maps and manuals
- Hengstler Encoders. Absolute encoders section, AC58 BiSS and SSI interface options
- Hengstler AC58 product family and SSI documentation. Supplementary reference for the stated model or setup.
- Hengstler AC58 SSI/BiSS technical data sheet. Order code, dimension drawings, SSI wiring by connector and mating accessories.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.