| TI-5000JX bench scope | Conditional serial position check after exact order, protocol, supply and clock/data fixture verification. No fieldbus or safety-function claim. |
|---|---|
| Starting lead / fixture | Exact-order clock/data fixture required; no dedicated lead named |
| Profile / module | Match SSI code/bit length or BiSS B/C profile to complete order. |
| TI-3000JX motor-run scope | No motor-run approval from device identity alone. Full motor, poles, power lead, alignment and installed run profile remain to verify. |
The admission evidence is Hengstler Encoders — Absolute Encoders (BiSS and SSI serial protocol), AX73 row. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Identify the fitted part
| Guide scope | Hengstler AX73 SSI / BiSS — Standalone device |
|---|---|
| Feedback identity | AX73 |
| Manufacturer MPN / full suffix | AX73 is the scoped family/designation. Match every additional character on the fitted label before ordering. |
| OEM service ID / motor order | Not established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately. |
| Interface | SSI or BiSS by complete order |
| Documented starting connection | Exact-order clock/data fixture required; no dedicated lead named |
| Material distinction | TCG175 is AX65; TCG260 is AR62; TCG292/320 are AC58. Separate housing and connection families; group related interfaces here. |
Production and replacement status
A manufacturer family or item record is linked below. Its presence is not confirmation that every historical suffix is available. Obtain current status and any proposed successor against the full label; fit, output, connector and motor data must all be checked.
Specifications and interface
| Enclosure and connection | Stainless steel AX73 with a detachable terminal-box arrangement; the linked SSI/BiSS sheet describes geared multiturn construction. |
|---|---|
| Resolution scope | Family document lists up to 22 singleturn plus 12 multiturn bits. Verify the exact order and tester profile. |
| Supply / output compatibility | Use the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide. |
| Exact dimensions, torque and pins | Use the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted. |
SSI and BiSS are distinct clock/data arrangements. Match protocol revision, code, bit length, turn allocation and timing to the full order. Where an analogue incremental output is optional, verify that it is actually fitted. An absolute word is not a generic A/B pulse count, and a manufacturer family maximum does not establish the installed tester capability.
Mechanical fit and retention
Photograph the incoming shaft/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model. Record the full Ex label and applicable certificate before work on the enclosure, gland or terminal arrangement. This guide does not establish permission to alter or repair certified protection features.
Record the hood, gland, terminal assignment and full order before reconnection. Its detachable termination is materially different from the integrated-cable AX70/AX71 construction.
Wiring and connector boundaries
Map five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.
Starting connection for this guide: Exact-order clock/data fixture required; no dedicated lead named. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
No internal OEM harness number or universal extension has been verified for this exact fitted order. Obtain the motor assembly drawing and photograph both loom ends before sourcing it. A fixed installation cable and a cable-carrier extension may have different flex and shielding requirements. Do not convert the Mitchell test-lead number into an OEM replacement part number.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| An AX73 connection hood was changed in the field | Record the hood, gland, terminal assignment and full order before reconnection. Its detachable termination is materially different from the integrated-cable AX70/AX71 construction. |
|---|---|
| Fault appears when the machine cable moves | With the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds. |
| No feedback or intermittent loss at the drive | After label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell. |
| Position reads but status or retained reference is wrong | Save detected identity, status and incoming position. Check the documented profile and retention arrangement before a reset, battery intervention or data transfer. |
Alignment, reference and memory
Record the incoming mechanical datum, direction and motor phase convention before disturbing the sensor. No numerical commutation angle or universal memory image is specified here. A motor-specific alignment requires the exact motor data, supported equipment setup and applicable OEM procedure. Preserve any recoverable offset, identity and parameter data before changes; establish hardware and data compatibility before a specialist transfer or write.
Motor and drive applications
Standalone device; supported serial options only. TCG175 is AX65; TCG260 is AR62; TCG292/320 are AC58. Separate housing and connection families; group related interfaces here.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Hengstler Encoders — Absolute Encoders (BiSS and SSI serial protocol), AX73 row
- Hengstler ACURO AX73 product announcement — AX73 detachable connection hood versus integrated-cable AX70/71. Select SSI/BiSS only; no certification or repair authorization inferred.
- AX73-BiSS_SSI_Datasheet_241016_EN.pdf — Manufacturer family datasheet. Read the ordering table, mechanical drawing and connection table for the complete fitted suffix.
- Manufacturer record / drawing directory — Select the complete fitted order; family identification is not a fit or stock guarantee.
Primary family/application PDF linked; exact fitted order, fixture, internal loom and alignment evidence remain to confirm.
Common questions
What should accompany a AX73 SSI / BiSS enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
No motor-run approval from device identity alone. Full motor, poles, power lead, alignment and installed run profile remain to verify. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation