Encoder and resolver technical library

KEBA / LTi LST-127-1 / G6.1M SRM50 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

KEBA / LTi LST-127-1 G6.1M SRM50 feedback technical guide and UAE service evaluation, TCG1510

KEBA / LTi LST-127-1 / G6.1M uses the documented SRM50 multiturn classic HIPERFACE option. This guide helps identify the fitted feedback, distinguish an encoder fault from a cable or setup issue, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.

Identification · Testing scope · Fault checks · Drawings and manuals · Service enquiry

Identify the fitted configuration

Item Documented scope
Manufacturer / motor base KEBA / LTi LST-127-1
Selected OEM feedback option G6.1M — SRM50, multiturn classic HIPERFACE
Identifier scope Motor base plus feedback selection; not a complete motor order. Confirm every fitted suffix.
Braked representative B — 24 V holding-brake option
Service reference TCG1510 — SpareFaber reference, not an OEM part number

Confirm the complete motor order, encoder suffix/serial, drive model and connector revision. The catalogue connects this base and option to the named feedback family; an exact Mitchell entry for this motor was not found in the reviewed material. That does not prevent scoped testing of the positively identified feedback.

Specialist feedback testing

TI-5000JX: identified SRS50 / SRM50 classic HIPERFACE feedback. Evaluate serial position and analogue signals; retain incoming alignment/memory.

Starting connection: TI-5069 direct to verified SRS/SRM 8-pin encoder plug; TI-5104 after label/supply check. Motor-bulkhead adapter is not established by this proposal.

Match the actual encoder selection and lead in the installed Athena software. Check identity/status and serial position, then evaluate the analogue path separately. A clean position count alone does not prove correct analogue amplitude or installed commutation alignment. Record the equipment, cable, software version and fitted encoder label with the result; no minimum firmware version is asserted for this exact assembly.

TI-3000JX motor-run scope: Unestablished for this exact motor. Confirm motor parameters, fixture, phase order, brake, alignment and installed TI-3000JX profile before run testing.

The MOOG reference is used only because it documents the identified encoder families and their direct connectors. It does not authorize a MOOG motor profile, machine cable or alignment value for this application.

Signals and specifications

Parameter Documented value / boundary
Motor base KEBA / LTi LST-127-1
Selected feedback G6.1M — SRM50, multiturn classic HIPERFACE
Interface Serial RS-485 absolute position plus analogue sine/cosine paths
Serial position per revolution 32,768 positions (15 bits)
Analogue periods per revolution 1,024 sine/cosine periods; not drive-scaled counts
Multi-revolution information 4,096 revolutions (12-bit turn range)
Feedback supply 7–12 V DC in the scoped OEM table; verify the fitted encoder label
Brake selection B — 24 V DC holding-brake option
Catalogue stall torque 6.6 Nm at the catalogue conditions; not continuous torque at every speed
G6.1x motor length with brake 231 mm, catalogue p.93; match shaft and connection options
Holding brake 24 V DC option B; 18 Nm catalogue braking torque, ±10%; p.93
Motor power / speed order Not assigned by this guide; read the complete motor nameplate and winding suffix

Analogue periods, serial positions, multi-revolution range and drive-scaled counts are different quantities. A catalogue period count is not an assumed controller resolution. Feedback supply, motor DC-link/drive supply and brake supply are separate circuits.

Mechanical fit and retention

LST-127-1 has 6.6 Nm catalogue stall torque. Its G6.1x motor length with the B brake option is 231 mm in the p.93 dimensional table. This is a catalogue motor-housing dimension, not an encoder body length or shaft diameter.

Use the LST-127 drawing on p.93 to compare the fitted shaft, flange, pilot and connection selection. A common frame or feedback family does not establish interchangeability between different motor lengths, S/K connection variants or special X builds. Confirm the complete speed/DC-link/winding fields rather than creating separate winding-only feedback guides.

Before loosening retention, preserve the incoming shaft reference and record the encoder locating seat, coupling, anti-rotation support and cable route. Exact internal fastener torques, air gap and fitted loom number remain specific to the complete assembly; obtain the relevant assembly drawing before replacement.

Wiring and connector boundaries

KEBA catalogue p.115 distinguishes the 17-pin M23 optical-encoder socket from the 12-pin resolver socket. Use the G6.x column below and the original connector drawing to establish view and keying.

OEM motor feedback contact Signal / scope
1 / 2 A+ / A−
3 / 4 B+ / B−
7 GND / 0 V
9 VCC 7–12 V / 100 mA
10 / 11 DATA+ / DATA−
8, 12, 13, 16, 17 Not used for G6.x in this table
5, 6, 14, 15 Not connected

In the adjacent SSI/EnDat column, pin 8 is +5 V and separate clock/sense contacts are present. Those assignments do not belong to G6.1S/G6.1M. Do not bridge pins 8 and 9 or substitute the neighbouring table. Match the complete S/K connection option and motor power/brake drawing independently.

Use the original drawing to confirm contact view, keying and revision before wiring. No pin assignment here is a terminal-block map for the Mitchell tester.

Internal, machine and test cables

TI-5069 direct to verified SRS/SRM 8-pin encoder plug; TI-5104 after label/supply check. Motor-bulkhead adapter is not established by this proposal.

The direct-to-encoder lead is an internal bench connection. The motor bulkhead connector, machine extension and drive-end connector form separate interfaces. No verified internal loom or complete machine-cable part number is established for this exact full order. Record both-end connector photos, cable markings, routing and required length before selecting a replacement harness.

Check the manufacturer drawing and current Mitchell lead sheet together before adapting a connection. A compatible communication protocol does not make a physical plug or pinout interchangeable.

Practical fault checks

Before physical checks, secure the driven load, isolate and lock out relevant energy sources, observe the specified discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short checks and account for intentional shield bonds. Powered measurement, rotation, brake release and alignment require the applicable specialist procedure.

Symptom Useful next check
No serial position or incorrect encoder identity Verify the fitted model and software choice, approved supply and serial pair, then inspect connector seating and cable condition. Separate cable and encoder tests before replacing the sensor.
Serial position reads but analogue path is weak or noisy Confirm the correct sine/cosine pairs and source amplitude using the approved signal test. Inspect shielding, contamination and cable damage; an incrementing serial count does not clear the analogue channels.
Position or direction changes after refitting Compare full feedback option, drive scaling/direction, preserved offset and mechanical reference. Do not copy an offset from a similar motor.
Turn information is unexpected after service Compare the saved incoming turn value, machine reference and actual shaft history under the approved test procedure. Preserve motor data before any reset or write; do not assume a turn discrepancy is a battery fault.
Fault follows cable movement With the installation isolated, inspect strain relief, pin retention, moisture and both-end cable continuity against the actual wiring drawing.
Motor will not turn or reports a run fault Check load/brake condition and the separately approved motor-run setup. A feedback pass does not prove correct brake release, winding connection or phase order.

Incoming alignment, offsets and memory

Before loosening, removing, resetting or programming the feedback, record the incoming mechanical reference, supported commutation/alignment reading, motor pole count, direction and phase convention. Preserve drive offsets and parameters with readable encoder identity, memory/status and offset data. Tie the record to the motor and encoder serials and the test setup.

Retain or reproduce a valid incoming alignment under the applicable specialist method, then verify it after refitting. Memory retention alone does not prove physical alignment. Where motor-specific memory decoding is unavailable, keep readable data without labelling a raw backup as a verified alignment value.

If the feedback was already disturbed, the reference is invalid, or memory is absent/corrupt/unreadable, record that limitation and obtain the motor-specific recovery method. No universal angle, automatic recovery, or default transfer from another motor is established here. Confirm hardware, data format and the complete motor order before any memory write.

For this multiturn SRM50 branch, preserve and assess the revolution count as well as the single-revolution reference.

Production and replacement status

The reviewed OEM-authored catalogue is KEBA document 0814.25B.8-00, 11/2022. The current manufacturer motor page provides an LSN/LST catalogue download. These references document the configuration; they do not establish stock, production status of every complete order, or a drop-in encoder successor. Confirm the complete motor and feedback labels and the applicable current drawing with the supplier before ordering.

Motor applications and related guides

G6.1S identifies SRS50 singleturn; G6.1M identifies SRM50 multiturn. The separate G6.2 family uses SKS36/SKM36 with 128 analogue periods, while G7 options are HIPERFACE DSL. A generic “HIPERFACE” description is not enough to substitute those branches. LST and LSN are distinct motor families even where encoder options have the same names.

Related pages below provide additional identification context. A related guide is not a replacement or compatibility approval for this complete motor order.

Drawings and primary documents

Exact application evidence: K1 p.14 Table 1.3 (G6.1S/M device/fit), pp.66–67 (LST order and brake codes), pp.70–71 Table 3.15 (motor bases), p.93 (LST-127 G6.1x dimensions and brake), p.115 (G6.x M23 connector).

Source scope reviewed 23 November 2026. Match the document revision, complete fitted labels and actual connector before using a drawing, replacement or test connection.

FAQ and service enquiry

Can this feedback be evaluated without an exact Mitchell motor entry?

Yes, once the fitted device, supply and connection are positively identified within the documented feedback scope. Evaluate serial position and analogue signals and preserve valid incoming alignment/memory. Motor-run approval remains a separate setup decision.

Can I replace this option with the paired singleturn/multiturn version?

G6.1S identifies SRS50 singleturn; G6.1M identifies SRM50 multiturn. The separate G6.2 family uses SKS36/SKM36 with 128 analogue periods, while G7 options are HIPERFACE DSL. A generic “HIPERFACE” description is not enough to substitute those branches. LST and LSN are distinct motor families even where encoder options have the same names. Verify drive support, mounting, wiring, exact suffix and motor data before considering substitution.

What information should accompany a service enquiry?

Send the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and service history. Include the cable labels and any saved incoming alignment/data record. SpareFaber can then scope a UAE site investigation or send-in evaluation.

Request a UAE site visit or send-in evaluation. Scope, parts and turnaround are confirmed after reviewing the fitted configuration and fault.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?