KEBA / LTi LST-190-1 Heidenhain EnDat Singleturn / Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
KEBA / LTi LST-190-1 with Heidenhain EnDat singleturn and multiturn options is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.
Identification · Testing · Specifications · Mechanical fit · Wiring · Alignment · Documents · Service enquiry
Identify the fitted motor and feedback
| Identification item | Scoped information |
|---|---|
| Manufacturer / grouped base | KEBA / LTi LST-190-1 |
| Reference | TCG1613; SpareFaber service-guide reference, not an OEM part number |
| Frame / family | 190 |
| Catalogue M0 / stall reference | 27 Nm; match the selected catalogue row, conditions and complete fitted order |
| Cooling / assembly | Catalogue standard motor; identify any external-fan/custom build |
| Motor-data source | KEBA LSN/LST order catalogue 0814.25B.8-00, 11/2022; motor table p.100 |
| Mechanical source | p.101 |
| Coverage boundary | singleturn and multiturn options; base identifier omits complete speed/winding/shaft/brake/factory suffixes |
Photograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed/winding fields. G12.1S / G12.1M — ECN1313 / EQN1325 is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.
G12.1S/M is separate from G3/G5 SSI and G6.x classic HIPERFACE. The full encoder number establishes its protocol revision and device data; a shared ECN/EQN family name is not an interchangeability statement.
Specialist feedback testing
Device-level test scope: Identify G12.1S ECN1313 or G12.1M EQN1325 as EnDat. Use the matching installed Heidenhain serial selection and exact fitted protocol revision. TI-5101 is relevant to the documented 1 Vpp A/B outputs; serial status and analogue quality remain separate observations.
Record the tester hardware, lead/module, software version, selected feedback type and actual fitted label with the report. First capture available position/status and supported identity without writes. Then compare the relevant serial, analogue or digital-link behaviour. A changing count alone does not prove correct mechanical installation, clean signal quality or a valid motor-data interpretation.
| Test record | What the observation establishes |
|---|---|
| Label and setup match | The selected protocol/device and supply are appropriate to the identified branch |
| Slow manual movement | Direction, continuity, cyclic changes and turn transitions can be compared |
| Status / alarm readback | Device-reported faults can be separated from a cable or controller symptom |
| Analogue levels where present | A/B quality can be examined independently of serial position |
| Before/after report | Incoming identity and any approved service change remain traceable |
Motor-run scope: TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture/load, brake handling and speed/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.
Motor data and singleturn/multiturn comparison
| Parameter | G12.1S singleturn | G12.1M multiturn |
|---|---|---|
| Encoder family | ECN1313 | EQN1325 |
| Protocol | EnDat + analogue | EnDat + analogue |
| Absolute positions / revolution | 8,192 (13 bits) | 8,192 (13 bits) |
| Multiturn range | Not applicable | 4,096 revolutions (12 bits) |
| Analogue periods / revolution | 2,048 | 2,048 |
| OEM connection | M23 17-pin optical-encoder branch | M23 17-pin optical-encoder branch |
| Catalogue supply / return | +5 V at pin 8 / 0 V at pin 7 | +5 V at pin 8 / 0 V at pin 7 |
The catalogue torque reference for this grouped base is 27 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed/winding/cooling condition. Keep stall M0, rated Mn and short-duration Mmax separate.
ST and MT coverage stays on one page for this interface family. A multiturn device adds a revolution range; it is not merely a controller setting that turns every singleturn assembly into a multiturn one. Absolute serial position, analogue signal periods and drive-scaled counts are separate quantities.
G12.1S/M is separate from G3/G5 SSI and G6.x classic HIPERFACE. The full encoder number establishes its protocol revision and device data; a shared ECN/EQN family name is not an interchangeability statement.
Mechanical fit, cooling and removal reference
Use p.101 for the 190-frame length/drawing table. G12.1x lengths are explicitly separated from other feedback columns. A G3/G5 SSI assembly still needs its actual holder and connector envelope identified; a similar ECN/EQN family name is not proof of identical fitted length.
| Fit item | Record and compare |
|---|---|
| Flange / pilot / mounting holes | Use the exact drawing and mounting version, including connector clearance |
| Shaft / key / coupler | Record actual dimensions, insertion depth and machine reference before removal |
| Encoder mounting | Identify holder, coupling, fasteners and mechanical reference from the fitted device |
| Brake and fan | Identify options and added envelope; verify their separate electrical circuits |
| Seals / coolant / enclosure | Match the actual cooling arrangement and ingress-protection build |
Mark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.
Mechanical drawings to compare: p.101. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.
Wiring and connector scope
The scoped pin list comes from KEBA's p.115, G3/G5/G12.x column for the optical encoder M23 17-pin socket. Verify drawing view, contacts, keying and actual revision before making a cable. The G6.x HIPERFACE column shares some signal locations but uses a different supply assignment.
| Scoped contact(s) / function | OEM G3/G5/G12.x assignment |
|---|---|
| 1 / 2 | A+ / A− |
| 3 / 4 | B+ / B− |
| 7 / 8 | 0 V / +5 V feedback supply, in the G3/G5/G12.x column |
| 10 / 11 | DATA+ / DATA− |
| 12 / 13 | CLK+ / CLK− |
| 16 / 17 | VCC sense / GND sense |
| 5, 6, 14, 15 | Not used in the reviewed optical-encoder table |
| Pin 9 | Do not apply the G6.x 7–12 V supply assignment to this +5 V branch |
Read connector drawings in their stated contact-side view and verify numbering, keyway, male/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.
Keep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.
Test leads, internal loom and machine cable
| Connection layer | What must be established |
|---|---|
| Direct encoder plug | Exact device connector and compatible bench lead; not automatically a motor-bulkhead connection |
| Motor internal loom | Continuity, shielding, strain relief and any changes made during earlier repairs |
| Motor feedback / hybrid bulkhead | Correct socket, contact view, branch and separate power/brake/thermal circuits |
| Machine cable | Both endpoint pinouts, length/routing, drag-chain damage and shield termination |
| Drive / tester end | Correct installed selection, supply module and interface-specific lead |
A device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.
The analogue and serial paths may fail independently. Preserve differential pair integrity and verify supply at the actual device where the documented sense arrangement permits. Do not bridge sense wires or reassign unused contacts without the fitted device's drawing.
No complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor/encoder labels and both connector endpoints are known.
Diagnostic symptoms and useful comparisons
| Reported symptom | Evidence to collect before changing parts |
|---|---|
| No position / no communication | Supply and return at the identified feedback branch, selection, interface and isolated cable continuity |
| Position changes but drive faults remain | Status codes, configuration, motor-data interpretation and phase/alignment relationship |
| Intermittent or noisy behaviour | Connector contact, strain/routing, shield integrity and signal quality through each cable layer |
| Incorrect direction or scaling | Recorded device direction, selected protocol/word format and drive scaling; do not rewrite offsets to hide it |
| Multiturn value unexpected | Fitted MT identity, documented turn range, incoming count and behaviour across a controlled turn boundary |
| Fault appeared after removal | Original reference marks, mechanical holder/shaft relationship, supported offsets and before/after reports |
Compare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.
Where the fitted branch exposes analogue A/B, inspect those outputs separately from serial position/status. A successful serial read is not a complete analogue-quality check.
Alignment, offsets and memory preservation
Capture incoming mechanical reference, supported electrical/commutation angle, offsets, position/status, identity and readable memory before removal or writes. Save a report that identifies the full motor, encoder, fixture, lead and selected software configuration. Preserve valid incoming data as the reference for any approved repair.
After mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.
Only use memory or electronic-alignment functions that are explicitly supported for the identified encoder and motor application. A generic device-level capability does not prove that every manufacturer's memory layout is understood.
If the original relationship or data is unavailable, define a motor-specific recovery method from documented motor/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before/after evidence and the exact change performed.
Service scope, replacement and availability
This is a technical-guide/service listing for KEBA / LTi LST-190-1, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.
A replacement decision must compare interface, absolute/analogue behaviour, supply, mounting, shaft/holder, connector route, thermal/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.
Provide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.
Applications and practical service enquiries
The selected 190 frame/family and 27 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment/data.
- Compare the exact motor and feedback branch during a repair intake.
- Document a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.
- Prepare an installation or reinstallation visit with complete labels, drive details and machine reference.
- Assess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.
Related interface guides for the same base: Heidenhain SSI — TCG1614. Each retains its own electrical scope.
Request installation, repair or alignment assessment and include reference TCG1613.
Drawings, manuals and evidence
- KEBA LSN/LST order catalogue 0814.25B.8-00, 11/2022 — readable reproduction of the same OEM-authored catalogue. Motor data: p.100; mechanical reference: p.101.
- Mitchell Heidenhain serial feedback reference. Confirm SSI/EnDat selection and exposed analogue channels.
- KEBA encoder/order tables: pp.14 and 66–67. Optical-encoder connector assignment: p.115. Use G3/G5/G12.x rather than the G6.x supply column.
These references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.
The cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor/encoder installed in a machine.
Frequently asked questions
Is this a complete factory motor order?
No. KEBA / LTi LST-190-1 is a guide grouping. Match all winding/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.
Why are singleturn and multiturn on one page?
They share this guide's interface scope, while their encoder labels, revolution range, mechanical variants and setup details remain distinguished in the comparison table.
Can I use another motor's cable or test selection?
Only after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.
Does feedback testing prove a motor-run setup?
No. Exact motor parameters, fixture/load, brake and phase/alignment conventions require their own motor-specific run-test approval.
Can the original alignment and data be preserved?
Capture available incoming identity, mechanical reference, supported angles/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.
How do I request service?
Send full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1613. Installation, repair, alignment and site/send-in scope follow identification.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.