What specialist testing can show
TI-5000JX bench. Match the fitted ECI ID and read the applicable serial and analogue signals.
TI-3000JX motor run. Mitchell lists AKM EnDat support. Confirm the actual LA motor, pole count and supported setup.
Starting lead. Use the verified AKM connector and fitted ECI lead. Exact lead depends on the frame.
Kollmorgen AKM LA ECI EnDat 2.1 Singleturn Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AKM LA, AKM2–3 | HEIDENHAIN ECI 1118, inductive singleturn. |
| AKM LA, AKM4–8 | HEIDENHAIN ECI 1319, inductive singleturn. |
| AKM LB | Inductive multiturn branch. The fitted feedback model and turn data differ. |
| AKM DA / DB | Optical EnDat branch. Match the complete motor and connection code before choosing a replacement. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | EnDat 2.1/01 on Kollmorgen’s LA table. |
| Incremental tracks | 16 periods per turn on AKM2–3 and 32 on AKM4–8 in that LA table. |
| Feedback supply | 4.75–10 V DC in the documented LA specification. Follow the drawing and approved test conditions for the actual drive. |
| Feedback temperature | −40 to +115 °C on the cited AKM2–3 LA and −20 to +115 °C on AKM4–8 LA. These are feedback ratings. |
Interface and measuring method
The inductive encoder returns singleturn absolute position by EnDat. The drive can also use the analogue tracks. A tester count after interpolation and the number of physical sine periods measure different things.
Mounting and fit
Match the ECI size to the motor frame before opening the assembly. Obtain the fitted HEIDENHAIN mounting drawing and confirm the locating seat, rotor attachment, scanning gap and cable route. Recheck fit if the alarm started immediately after bearing work.
Wiring and connector scope
Use the AKM LA connection code and the corresponding Kollmorgen pin table. Identify clock and data pairs, analogue tracks, supply and return at the motor bulkhead before mapping the internal connector.
Internal motor and machine cables
Kollmorgen groups the mating cable by connection code and drive. Use the fitted motor and drive orders to identify the cable assembly. The internal encoder harness follows the fitted ECI drawing and motor parts list.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial position reads but analogue interpolation alarms | Check the sine tracks for the actual 16- or 32-period unit and the analogue cable pairs. |
| No feedback after the motor was changed | Check the full LA frame, connector option, approved supply and drive feedback selection. |
| Position degrades after rear-end work | Check the seating and scanning gap against the fitted ECI drawing. |
Angle of alignment and commissioning
The Kollmorgen LA/LB specification gives a specialist reference within ±3 electrical degrees for its stated +W/−V convention with U open. Record the incoming direction, reference and memory where fitted. Verify the motor and full OEM procedure before applying the alignment reference.
Motor and drive applications
Kollmorgen AKM LA by frame
Decode LA, match the inductive encoder by frame and preserve its fitted gap and reference.
Related SpareFaber guides
Drawings, pin maps and manuals
- Kollmorgen AKM support. Mitchell-linked AKM Feedback Description, LA row and frame footnote
- Kollmorgen AKM connectivity manual. Manufacturer reference for the indicated motor or feedback option. Check the fitted revision.
- Mitchell-linked AKM Feedback Description. Reference for the fitted feedback or motor option.
- Kollmorgen AKM selection guide. AKM Feedback Type Specifications, EnDat Inductive LA/LB. Frame mapping, feedback ratings and alignment convention.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.