What specialist testing can show
TI-5000JX bench. Check turn data, position and connector by the full order and applicable frame revision.
TI-3000JX motor run. Match the complete AKM LB order, drive and motor-specific run setup.
Starting lead. Select the AKM connection and qualified EnDat fixture for the fitted EQI.
Kollmorgen AKM LB EQI 1130 / EQI 1331 EnDat Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AKM LB, AKM2–3 | EQI 1130 in the cited Kollmorgen order table. |
| AKM LB, AKM4–8 | EQI 1331 in the cited order table. Confirm the fitted ID and revision. |
| AKM LA | Inductive singleturn ECI branch. Compare position format and mechanical fit. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | EnDat 2.1/01 in the cited AKM inductive feedback table. |
| Analogue periods | Kollmorgen lists 16 for AKM2–3 and 32 for AKM4–8 in the applicable LB table. |
| Position format | Inductive multiturn. Use the motor order and encoder ID to confirm the complete data format. |
Interface and measuring method
The drive reads absolute within-turn position and turn information. Check the analogue tracks separately where used. The frame determines the encoder size and period count in the cited table.
Mounting and fit
Obtain the exact EQI motor drawing for the frame. Check rotor seat, sensing gap and cable routing before changing the assembly. Preserve the incoming reference and compare the full encoder ID.
Wiring and connector scope
Use the fitted AKM EnDat connection drawing. Identify the power, data and clock circuits and the analogue tracks where present. Verify the internal and motor-side connector views independently.
Internal motor and machine cables
Choose the OEM cable from the AKM connection code and drive. Keep the internal EQI harness and the machine extension separate when tracing faults.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Within-turn reading works but turn count is wrong | Check the LB model and controller turn format. |
| Analogue signal alarm with valid serial data | Compare the actual frame’s tracks and trace the analogue pairs. |
| Fault begins after bearing or encoder work | Check sensor spacing, seating and fitted EQI ID. |
Angle of alignment and commissioning
Record direction, full turn reference and original motor data. Confirm Kollmorgen’s phase and alignment convention for the actual frame and drive before entering a reference or running a replacement.
Motor and drive applications
AKM LB with the documented feedback frame and connector
Match EQI 1130 or EQI 1331 to the motor frame and compare the turn field and installation requirements with LA.
Related SpareFaber guides
Drawings, pin maps and manuals
- Kollmorgen AKM support. Mitchell-linked AKM Feedback Description, LB EnDat and motor-family coverage
- Kollmorgen AKM selection guide Rev E, EnDat Inductive LB. Supplementary reference for the stated model or setup.
- Mitchell-linked AKM Feedback Description. Reference for the fitted feedback or motor option.
- Kollmorgen AKM installation manual. Feedback option table, LB EQI 1130 and EQI 1331 motor-frame mapping.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.