Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use manufacturer and elevator controller diagnostic states to separate tape detection, communication and configured speed. Keep the safety chain intact and use the site-approved procedure for any controlled movement.
Kübler Ants LES03 5 m CAN Elevator Shaft Position Sensor technical reference
Find your part number
Use the full label and suffix. The main reference is 8.LES03.111A.1111.0000.0050. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 8.LES03.111A.1111.0000.0050 | Mounting plate, special 5 m shielded open-end cable. The 0050 suffix encodes length in decimetres. | 10–30 V DC, proprietary single-channel CAN profile, rated elevator speed unset at order. |
| LES03 cable option 1 | Standard 3 m open-ended cable. | Check the remaining order fields and commissioning record. |
| 8.LEX.BA family | Absolute coded band ordered by measuring length. | Separate shaft component. Match the band and mounting kit to the site design. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measurement | Non-contact absolute position and travel speed from the Ants coded band. Published resolution is 0.5 mm functional and 1 mm certified. |
| Supply and connection | 10–30 V DC. Shielded 5 m open-end lead in this worked order code. |
| System components | LES03 head, LES.MK mounting kit, LEX.BA coded band and site-specific CS configuration strip. |
| Head envelope | 126 × 55 × 37 mm in the sensor datasheet. Check the bracket and band envelope separately. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The car-mounted head reads a fixed coded band in the shaft. A qualified elevator technician can check for a shifted bracket, damaged band or band rubbing after securing the car and following the site isolation and shaft access procedure. Use the specified mounting kit and installation dimensions for band routing and fastening.
Interface and measuring method
The sensor sends position and speed over Kübler's proprietary single-channel CAN profile. A replacement needs the matching controller and approved configuration for that elevator. Diagnose power, network communication and position validity separately.
Verified wiring
| Conductor | Function |
|---|---|
| Brown (BN) | Supply +V |
| White (WH) | 0 V |
| Green (GN) | CAN_H |
| Yellow (YE) | CAN_L |
Match the cable option on the full label and use the elevator schematic for shield bonds and CAN termination. Make checks at the documented access point. Obtain approved settings from the elevator commissioning record.
Cables inside the motor and at the machine
The exact worked code has a factory 5 m shielded lead. The datasheet gives a 3 m standard version and 5, 7 and 10 m special lengths. Identify the controller-side termination from the elevator documentation. Select the configured cable length and mounting style together.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Position invalid in a repeatable part of the shaft | Check the corresponding band area, bracket geometry and guide path under the site isolation procedure. |
| Controller loses communication | Check the exact device/profile, approved supply, isolated loom and network diagnostics. |
| A replacement shows configuration or speed faults | Verify the specified CS strip and commissioning record with the elevator OEM. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This guide applies to the exact Ants Safe configuration in the datasheet. Confirm the fitted controller, band and safety system design with the site documentation before ordering or adjusting the unit.
Angle of alignment and commissioning
Restore geometry to the manufacturer's installation instructions. Rated speed teaching uses the approved configuration strip and belongs to qualified elevator commissioning. Return to service only under the required site checks and authorization.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Kübler LES03 technical data. Use the order code, component matrix, terminal assignment and mounting-kit overview.