What specialist testing can show
TI-5000JX bench. Check ABZ and distinguish the matched differential or push-pull circuit by actual part.
TI-3000JX motor run. Confirm the motor type and supported run setup separately.
Starting lead. TI-5614 on the documented 12-contact M23 connection.
Lenze MDFK / Thalheim Incremental ABZ Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| Lenze MDFK ABZ | Mitchell TI-5614 cable-index branch for a 12-contact M23. |
| MDFK 08T | Baumer family example, 5 V ±5% RS-422, with complementary signals. |
| MDFK 08G | Baumer family example, 8–30 V DC push-pull. Use its own receiver and wiring. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Sensing construction | Baumer MDFK08 family uses a magnetic wheel and bearingless sensor. |
| MDFK08 family resolution | 256–1,024 pulses per revolution by order, with optional reference. |
| MDFK08 mechanical example | Sensor 15 × 8.5 × 45.5 mm and working distance under 0.6 mm in the Baumer sheet. Check whether the motor actually has this assembly. |
Interface and measuring method
The wheel’s magnetic pattern produces A and B with a quarter-cycle shift. Use the correct input for the fitted RS-422 or push-pull output. The reference pulse option must also match the original application.
Mounting and fit
Compare the wheel and sensor mounting against the fitted drawing. Check accessible locating surfaces, wheel runout and approved sensor clearance before replacing the head. A gap change can affect feedback even when supply and cable continuity are good.
Wiring and connector scope
Use the Baumer data sheet for the actual sensor output and the Lenze drawing for the M23 bulkhead. A short sensor lead can have a different wire map from the motor connector.
Internal motor and machine cables
Use TI-5614 on the documented Lenze test branch. Record the original M23 harness and cable exits separately from the sensor’s own pigtail.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Counts disappear in a portion of the turn | Inspect wheel seating, runout and sensor clearance. |
| No signal after moving to a different receiver | Compare RS-422 and push-pull order, supply and return paths. |
| A/B works with no reference | Verify that the fitted order includes the N/Z channel and trace that path. |
Angle of alignment and commissioning
Record the wheel orientation, direction and reference index position before removal. Restore the manufacturer spacing and verify repeatability at a known position after fitting.
Motor and drive applications
Lenze assembly with fitted MDFK and documented 12-contact M23
Identify the bearingless sensing assembly, correct output and air-gap drawing on the fitted MDFK build.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer. Lenze and Thalheim sections, TI-5614 MDFK ABZ 12-contact M23
- Baumer Thalheim MDFK 08 RS422 family example. Supplementary reference for the stated model or setup.
- Baumer MDFK08 data sheet. Mechanical drawings, output variants and connection assignments for the MDFK08 reference family.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.