What specialist testing can show
TI-5000JX bench. Test the ERN 1387 on the named FIP/FHP connection, using the exact fitted pin map.
TI-3000JX motor run. Confirm the actual motor and phase convention. The Siemens reference is a signal comparison.
Starting lead. TI-5616 on the documented 17-contact M23 FIP/FHP branch.
Lust / Stromag FIP / FHP · ERN 1387 1 Vpp Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| FIP / FHP with ERN 1387 | Mitchell names this exact motor and encoder combination on TI-5616. |
| ERN 1387 ID 749144-01 | HEIDENHAIN reference example with 65B taper and 06 coupling. Use it only when the fitted ID matches. |
| Stromag with HEIDENHAIN SSI | A separate feedback option in the Mitchell index, with a different test lead. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Example encoder signals | ID 749144-01 has 2,048 lines, about 1 Vpp and one sine/cosine commutation period per turn. |
| Example encoder fit | 65B taper, 9.25 mm functional diameter and 06 expanding-ring coupling in the cited HEIDENHAIN order. |
| Motor connection | TI-5616, 17-contact M23. Confirm the fitted Lust/Stromag pin map before applying power. |
Interface and measuring method
The incremental tracks report position change. The extra one-period track pair supplies a commutation reference on documented ERN 1387 configurations. Check the fitted motor’s use of the tracks before choosing a test.
Mounting and fit
Read the full ERN ID and use its mating drawing. Check taper seating, the center fastener, stator coupling and clearance as part of the approved procedure. Capture the existing motor reference before removing the encoder.
Wiring and connector scope
Use the FIP/FHP motor-side diagram and exact HEIDENHAIN internal connector drawing. The Siemens article helps identify signal types. The Lust/Stromag drawing defines the motor bulkhead pin assignments.
Internal motor and machine cables
Record the original internal-to-M23 harness and the extension separately. Check the shield and all differential pairs against the fitted drawings before ordering a replacement.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Feedback works directly but fails on the motor | Check the internal loom and 17-contact M23 for continuity and contact retention. |
| Incremental tracks present, enable fault | Verify commutation channels and the received motor reference. |
| Signal degrades after fitting | Check taper seating, stator restraint and connector strain. |
Angle of alignment and commissioning
Capture the FIP/FHP electrical phase reference, direction and original angle. Use the motor-specific procedure. Siemens phase-angle values belong to the documented Siemens setup.
Motor and drive applications
Lust or Stromag FIP/FHP with documented ERN 1387 and 17-contact M23
Identify the correct FIP/FHP motor-side cable before tracing analogue or commutation faults.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer. Lust and Stromag sections, TI-5616 FIP/FHP ERN1387
- Siemens motors with HEIDENHAIN ERN1387 or Hengstler S21 / RS53. Supplementary reference for the stated model or setup.
- HEIDENHAIN ERN 1387 ID 749144-01. Example for signal data, 65B shaft and D319274 connection. Confirm the fitted ID.
- HEIDENHAIN encoders for servo drives. ERN 1387 family signal and mounting tables.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.