Identify the fitted part
| Guide scope | Mitsubishi Electric HG-JR503 — motor feedback application |
|---|---|
| Feedback identity | OBA/OSA18 tester identity; preserve actual OBA/OSA24R or fitted label |
| Main model / application identifier | HG-JR503 |
| Motor order scope | OEM standard motor model, without brake or reducer; verify all fitted suffixes |
| Interface | 22-bit OEM serial; Mitchell OBA/OSA18 selection |
| Starting connection | CMV1-R10P 10-contact feedback connector: TI-5732 only after confirming contact/key view; two-wire serial data. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Conditional TI-5000JX scope. 5 kW, 3,000 rpm; 130 mm square flange. Check the standard shaft, power connector and two-wire serial feedback connection. OEM 22-bit specification and Mitchell OBA/OSA18 tester selection are different descriptions. Do not change the tester selection solely to match the advertised bit count. |
|---|---|
| Starting lead / fixture | CMV1-R10P 10-contact feedback connector: TI-5732 only after confirming contact/key view; two-wire serial data. |
| Profile / module | OEM 22-bit specification and Mitchell OBA/OSA18 tester selection are different descriptions. Do not change the tester selection solely to match the advertised bit count. |
| TI-3000JX motor-run scope | Use only the documented Mitsubishi serial run path after confirming actual feedback, poles, direction, winding voltage and amplifier current/speed envelope. These catalogue ratings are not a claim of full-power tester capability. |
The documented test reference is Mitsubishi HG Series Motors - Melservo J4 Drives — Mitchell HG HG-JR named option; SH-030113ENG-P printed p.8-35, PDF p.302. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
The linked manufacturer record documents this configuration. Current production, stock and an approved successor for the complete fitted order still require manufacturer confirmation. A historical manual or downloadable CAD drawing does not prove present availability. Match voltage, mounting, shaft, brake, feedback, connector and motor-data requirements before ordering.
Specifications and interface
| Feedback technology | 22-bit OEM serial; Mitchell OBA/OSA18 selection |
|---|---|
| Rated motor output | 5 kW |
| Rated speed | 3,000 rpm |
| Motor flange | 130 mm square |
| Shaft diameter / tolerance | 28 h6 mm |
| Pilot diameter / tolerance | 110 h7 mm |
| Power receptacle | MS3102A22-22P |
| Feedback receptacle | CMV1-R10P, 10 contacts |
| Standard drawing | SH-030113ENG-P printed p.8-35, PDF p.302 |
| Order scope | Standard motor without electromagnetic brake or reducer; confirm any additional fitted suffix. |
| Standard motor mass | 18 kg |
| Service values | Encoder coupling dimensions, exact pin map and tightening torque require the fitted assembly drawing. No value is inferred from a related motor. |
The 22-bit figure is the OEM encoder specification. Mitchell names OBA/OSA18 as the test selection for HG-SR, HG-JR, HG-RR and HG-UR. Preserve both descriptions instead of treating them as contradictory part numbers. Two-wire describes the serial data connection, not the entire motor cable or a physical A/B/Z output.
Mechanical fit and retention
Record the incoming shaft datum, pilot, bolt pattern, rear clearance, cable exit and retaining arrangement before removal. Use the exact drawing for tolerances and fastening. Do not infer encoder coupling dimensions or tightening torque from the motor flange size. Inspect looseness, bearing play, debris and moisture before disturbing the feedback attachment. Use the exact HG-JR503 drawing, not the adjacent model on the same page. The 28 h6 mm shaft and 110 h7 mm pilot determine coupling and locating fit; the 130 mm flange dimension alone is insufficient. Check shaft projection, bolt-circle dimension and connector clearance on the linked drawing. A similar power rating in another HG family does not establish the same shaft or pilot.
HG-JR503 is the standard 5 kW, 3,000 rpm motor with a 130 mm square flange. The exact standard drawing identifies a 28 h6 mm shaft, 110 h7 mm pilot and MS3102A22-22P power receptacle. Preserve every additional nameplate suffix; the braked or geared version has a separate outline.
Wiring and connector boundaries
Keep motor power, protective earth, feedback, temperature sensing and any holding brake as separate circuits. Establish contact numbering, keying, gender and whether the drawing shows the mating face or wire side. Do not infer a pin map from a connector shell. This standard outline shows MS3102A22-22P for motor power and CMV1-R10P for feedback. Use the TI-5732 10-contact DDK drawing only after matching the actual feedback connection. HG feedback uses the newer two-wire serial data arrangement; the older four-wire Mitsubishi data cable is not a substitute.
Starting connection for this guide: CMV1-R10P 10-contact feedback connector: TI-5732 only after confirming contact/key view; two-wire serial data.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
Record the internal encoder-to-motor loom separately from the external machine cable and test fixture. The internal loom part number is not established by the motor model alone. Obtain the assembly drawing and both connector faces. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation; a Mitchell test lead is not an OEM replacement cable.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Identify before testing | HG-JR503 is the standard 5 kW, 3,000 rpm motor with a 130 mm square flange. The exact standard drawing identifies a 28 h6 mm shaft, 110 h7 mm pilot and MS3102A22-22P power receptacle. Preserve every additional nameplate suffix; the braked or geared version has a separate outline. |
|---|---|
| Intermittent fault with cable movement | After isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and previous repairs. Compare continuity and unintended shorts with the exact diagram, allowing for intentional shield bonds. |
| No serial data or unstable position | Confirm the profile, low-voltage supply at the correct boundary and mating-face pin assignment. Compare the test fixture with the actual motor connector; a plausible connector fit does not prove electrical compatibility. |
| Feedback reads but the drive rejects it | Record the original alarm and check exact motor identity, stored data requirements, direction, mechanical attachment and the supported signal paths. A reset is not proof of a compatible replacement. |
| Replacement dimensions look close | Compare the exact model, shaft, pilot, brake, seal, cooling and connector options above with the linked drawing before ordering or removing the original assembly. |
Alignment, reference and memory
Preserve the original mechanical reference, motor phase convention, direction and readable drive data before disassembly. Use the fitted motor and encoder service procedure for replacement. Communication alone does not prove correct alignment or machine origin. Select the verified OBA/OSA18 test identity for this HG family even when the fitted label says OBA/OSA24R or the OEM specification says 22-bit. Preserve incoming identity and motor-specific calibration. Supported motor-run work requires the documented serial profile and successful setup/debug checks with the exact winding and amplifier limits; the motor rating is not the tester output rating.
Motor and drive applications
HG-JR · 5 kW · 3000 rpm · 130 mm square flange. HG-JR503 is the standard 5 kW, 3,000 rpm motor with a 130 mm square flange. The exact standard drawing identifies a 28 h6 mm shaft, 110 h7 mm pilot and MS3102A22-22P power receptacle. Preserve every additional nameplate suffix; the braked or geared version has a separate outline.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Mitsubishi HG Series Motors - Melservo J4 Drives — Mitchell HG HG-JR named option; SH-030113ENG-P printed p.8-35, PDF p.302
- Mitsubishi MELSERVO-J4 catalogue — Use the stated family, option and document revision only
- Mitsubishi Motors — Named motor family and feedback option; row locator identifies scope
- Mitsubishi HG servo motor instruction manual SH-030113 — Use the stated family, option and document revision only
Obtain the complete fitted motor and encoder labels, exact service ID, internal loom, connector mating-face drawing and approved setup. Match the linked OEM document revision; unverified supply, pins, retention fasteners and alignment values remain open.
Common questions
What should accompany a HG-JR503 enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
Use only the documented Mitsubishi serial run path after confirming actual feedback, poles, direction, winding voltage and amplifier current/speed envelope. These catalogue ratings are not a claim of full-power tester capability. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation
Use the existing encoder enquiry form with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.