Site visit or send-in evaluation
Send the full HF-SP model and serial, OSA18 marking and suffix, amplifier model, exact AL code and photos of the motor connector and cable markings. Note whether the fault occurs at power-up, at enable or while moving. Use the enquiry form to share the details.
What specialist testing can show
Mitchell documents TI-5000JX testing for supported Mitsubishi serial encoders and describes why a replacement can report a different programmed ID from its base model. Verify the actual ID, Athena profile and lead for the OSA18 motor assembly before testing. The exact 191247 motor combination was not verified on the TI-3000JX. Where a run is supported, use the exact motor configuration and verify commutation on a secured, guarded fixture. Mitchell Mitsubishi encoder test and ID notes · Mitchell Mitsubishi motor run documentation
Mitsubishi Electric OSA18 HF-SP Encoder technical reference
Find your part number
Read the complete motor and encoder labels before ordering. Mitsubishi lists 191247 for the spare named HF-SP52 up to 702(B) encoder OSA18. Match the actual motor code and serial to the service part, including any encoder suffix and brake or connector option.
| Label / code | What the source verifies | Use it to |
|---|---|---|
| 191247 · OSA18 | Mitsubishi European spare listing for HF-SP52 up to 702(B) | Confirm replacement by the actual motor and serial. |
| OSA17 / OSA14 | Related Mitsubishi serial examples in Mitchell’s guide. Some replacements are configured for a lower resolution. | Confirm the programmed ID and exact profile. The base name alone does not establish interchangeability. |
| HF-SP52 / HF-SP52B | Motor order examples in the Mitsubishi J3 catalogue. B indicates the brake variant in the motor outlines. | Select the exact cable and motor service drawing. |
Mitsubishi OSA18 service spare · Mitsubishi HF-SP motor catalogue (PDF) · Mitchell model identification
Production and end-of-life status
Mitsubishi’s European catalogue identifies OSA18 spare 191247. Mitsubishi labels the MR-J3 drive family discontinued. Production and availability of the exact OSA18 service assembly require confirmation by motor serial. Reviewed 7 November 2026. Mitsubishi spare part record · Mitsubishi drive lifecycle and manuals
Specifications
| Parameter | Value / source boundary |
|---|---|
| Feedback class | Mitsubishi serial motor feedback for the approved HF-SP build. |
| System resolution | MELSERVO-J3 catalogue gives 262,144 positions per revolution for the documented motor system. Confirm the actual programmed encoder and motor combination. |
| Drive-side encoder supply | P5 and LG on the documented MR-J3-A CN2. The application drawing identifies the encoder power and return. |
| Motor connection | Mitsubishi HF-SP outline identifies CM10-R10P for the documented external encoder connector. |
| Mechanical and environmental limits | Use the exact HF-SP motor outline and service drawing. The spare listing does not publish encoder-only fit, torque, supply tolerance or operating limits. |
Mitsubishi J3 motor specifications and dimensions (PDF) · Mitsubishi MR-J3-A signals and wiring (PDF)
Mounting and fit
The encoder is located in the motor’s rear feedback assembly and follows shaft rotation. Preserve the original seating, mechanical index and harness routing. Inspect the motor cover, connector mounting, signs of impact and bearing play. The HF-SP catalogue provides the motor outline and external connector. Use the exact serial-specific service drawing for internal rotor retention, stator seating, fasteners and alignment. A public motor outline cannot establish internal adjustment dimensions. HF-SP outlines and connector drawings (PDF)
Interface and measuring method
The amplifier exchanges Mitsubishi serial feedback on the documented differential interface. It uses encoder position and status to control the motor. The system’s absolute option also depends on its documented backup circuit and reference setup. Check communication, mechanical feedback and position retention as separate functions. A different replacement profile can respond electrically and still be unsuitable for the motor.
Verified wiring
| CN2 pin(s) | Marking and role |
|---|---|
| 1 / 2 | P5 / LG, encoder supply and return |
| 3 / 4 | MR / MRR, paired serial signals shown in the manual |
| 7 / 8 | MD / MDR, additional pair in the documented CN2 map. Connect only as the exact cable drawing specifies. |
| 9 | BAT on the documented absolute wiring |
Use the manual view for the exact connector version. Mitsubishi also publishes the HF-SP motor connector outline. The CN2 numbers do not specify the motor connector or the OSA18 PCB. Keep other pins open or routed only as the applicable wiring diagram requires. MR-J3-A CN2 drawings (PDF) · J3 and J4 connector differences (PDF) · HF-SP motor connector outline (PDF)
Cables inside the motor and at the machine
| Part number | What it connects |
|---|---|
| MR-J3ENSCBL5M-L | 5 m standard bending life option for the documented HF-SP direct encoder connection. |
| MR-J3ENSCBL5M-H | 5 m long bending life option. Confirm actual motor and amplifier. |
| MR-J3SCNS / MR-J3SCNSA | Straight / angled connector set options listed for supported HF-SP configurations. |
| CM10-SP10S-M (D6) | DDK straight motor-side mating connector component in the MR-J3SCNS kit. |
Read the cable suffix, including any vibration option. Match both ends, shield and absolute-position wiring. The in-motor OSA18 lead and PCB map require the exact service drawing or a confirmed replacement assembly. Mitsubishi MELSERVO-J3 cable and connector ordering (PDF)
Fault checks
Secure the load and preserve the incoming position. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Include any absolute backup circuit in the safe test plan.
- Inspect. Check the CN2 latch and motor connector for bent or backed-out pins, oil, dirt, crushed wires, poor strain relief and a disturbed rear cover.
- Check the isolated harness. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Compare the exact cable drawing before interpreting any omitted or bridged conductors.
- Check power and alarm state. With an approved breakout fitted while off, a qualified technician can verify the P5/LG voltage at the documented CN2. Use the drive manual and approved diagnostics to check communication and battery status. Read the exact alarm and detail code, including AL.16 or AL.20 where applicable.
- Separate the possibilities. If the fault changes with cable movement, inspect contacts and flex points first. If a known-good matched cable and supply leave the same fault, check the installed encoder ID and the motor. If communication is healthy and torque trips began after replacement, check the approved alignment and motor setup.
Motor and drive applications
Mitsubishi lists spare 191247 for the named HF-SP range and documents the HF-SP52(B) motor outline in its J3 catalogue. Use the specific amplifier compatibility table, complete model code and connector drawing. When migrating to J4, review Mitsubishi’s CN2 and cable differences. Mitsubishi spare applicability · Mitsubishi HF-SP application data (PDF) · Mitsubishi MR-J3 to MR-J4 transition (PDF)
Angle of alignment and commissioning
Record original drive settings and absolute machine position before removing the encoder. The motor’s commutation alignment and the machine’s absolute datum are separate. If the repair procedure calls for restoring data, verify the exact motor and compatible replacement, restore only the authorized values, then read back and verify direction, commutation and reference. Obtain the motor-specific service procedure for the internal offset. The OSA18 family label supplies no universal angle.
Drawings, pin maps and manuals
- Mitsubishi Electric OSA18 191247 catalogue record. Exact service spare and named motor range.
- Mitsubishi MELSERVO-J3 catalogue (PDF). HF-SP outline, encoder connector and cable ordering.
- Mitsubishi MR-J3-A instruction manual SH-030038 (PDF). CN2, alarms and absolute position setup.
- Mitsubishi J3-to-J4 transition handbook (PDF). CN2 wiring and cable compatibility by drive series.
- Mitchell Mitsubishi serial encoder test reference. Verify actual programmed ID and supported profile.