Encoder and resolver technical library

Moog G-6-V8 / 04 HIPERFACE MT Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

Moog G-6-V8 / 04 HIPERFACE MT SpareFaber service card.

Moog G-6-V8 / 04 — HIPERFACE MT. This guide helps identify the fitted feedback, distinguish a cable or setup fault and prepare a scoped repair, installation or alignment assessment. SpareFaber accepts UAE site-service and send-in evaluation enquiries after reviewing the motor/feedback labels and fault history.

Identification · Testing scope · Fault checks · Drawings and manuals · Service enquiry

Identify the fitted configuration

Item Verified scope
Manufacturer / application Moog G-6-V8 / 04
Feedback HIPERFACE MT — SRM 50
Identifier scope Base motor + feedback selection; remaining nameplate suffixes are not specified.
Motor mounting 190 mm flange (size 6)
Braked representative G-6-V8 / feedback 04 / electrical option 02 (brake 2, rotatable connector)
Holding brake Legacy brake option 2; 72 Nm
SpareFaber service reference TCG1414

The service reference is not an OEM part number. Verify the complete fitted labels and connector revision before selecting a replacement or test connection.

Specialist feedback testing

TI-5000JX: legacy G-series fitted SRS50 / SRM50 feedback, using the documented direct-to-encoder route. Preserve incoming memory/alignment.

Starting connection: TI-5069 direct-to-encoder, 8-pin Berg. No universal external Moog bulkhead lead is claimed.

Module / software: TI-5104 required. Confirm actual SRS/SRM software selection and hardware revision; minimum firmware is unspecified.

TI-3000JX motor-run scope: TI-3000JX support not established for these complete legacy orders. Do not borrow TI-5920/TI-3032 from Mitchell’s resolver wiring example. Confirm brake, connector, winding, limits and run profile separately.

Signals and specifications

Parameter Documented value / limit
Legacy feedback selection 04 — SRM 50
Interface Classic HIPERFACE multiturn
Motor size / flange Size 6 / 190 mm
Representative electrical option 02: brake option 2 with rotatable connector, per 2015 table
Representative holding brake 72 Nm (legacy option 2)
Remaining full-order fields Rated-speed code, mechanical option and special version from the actual label
Encoder signals Serial absolute position plus analogue channels; exact revision ratings from the fitted encoder
Current-code distinction Legacy 03/04 is not current EnDat 09/10

Signal periods, serial position bits, turn range and drive-scaled counts describe different quantities. Use the exact encoder option and controller configuration when comparing readings.

Mechanical fit and retention

The May 2015 ordering table admits SRS50/SRM50 at size 6; the motor size corresponds to a 190 mm flange. The V8 selection identifies this base/stack, not a complete motor order. Obtain its installation drawing before using rear-housing length, shaft or connector-clearance measurements for replacement.

The representative uses electrical option 02: high holding-brake option 2 and a rotatable connector. The 2015 table gives 72 Nm for this size. Do not transfer the current catalogue’s encoder-housing dimensions or a different size’s brake rating into this legacy build. The motor’s mechanical and special-version suffixes still control exact fit.

Wiring and connector boundaries

The 2015 manual, PDF page 23 (printed page 18), directs wiring to the installation drawing supplied with the motor. Its encoder cable table specifies a 17-conductor signal scheme and mating connector C08666-001. That reference is an OEM mating connector, not a Mitchell direct-to-encoder test lead or proof that every customised motor has the same pin map.

Mitchell’s G/G4xx Stegmann Absolute Encoders section identifies SRS50/SRM50 and a direct-to-encoder test route. Match the installed encoder and its connector before testing. No unverified motor-bulkhead pin assignments are reproduced here; use the exact motor installation drawing and Mitchell’s scoped wiring diagram.

Internal, machine and test cables

TI-5069 direct-to-encoder, 8-pin Berg. No universal external Moog bulkhead lead is claimed. TI-5104 required. Confirm actual SRS/SRM software selection and hardware revision; minimum firmware is unspecified.

The OEM manual lists B47711-001 as the power mating connector for G-5-x9 and G-6; the general power connector table lists C08365-001/C08365-002 with cable-size conditions. These are loose mating-connector references, not complete machine cable numbers. Read the matching table and actual motor drawing before selection.

The internal encoder loom, finished machine cable and any replacement adapter remain unverified for the full order. Mitchell’s TI-5920/TI-3032 references are under its resolver wiring example; they are not automatically the leads for this HIPERFACE motor.

Practical fault checks

Follow the site isolation procedure before physical checks: secure the driven load, lock out relevant energy sources, observe the drive discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short testing and account for intentional shield bonds. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure.

Observed symptom Useful next check
No communication with the feedback Read the actual encoder label and legacy order code; confirm SRS/SRM selection, TI-5104 module and the direct connector before investigating the device.
Position reads but analogue quality is poor Check the matched test setup and signal path; distinguish cable/connector contamination from encoder optical or mechanical faults using the approved bench procedure.
Fault appears after exchanging a motor or feedback Compare legacy/current feedback codes, complete motor suffixes, drive support and stored alignment. A matching flange alone is insufficient.
Brake or power issue during testing Separate the holding-brake circuit and motor power connection from the successful feedback test. Confirm the actual brake build and powered-run limits.
Wrong absolute position across power cycles Record serial position, turn value and drive offsets before resets. Do not assume a battery or retention procedure without identifying the fitted encoder revision.

Alignment, offsets and memory

Preserve the incoming encoder mounting reference, serial/memory data, offset, motor direction and phase convention before internal access. The legacy feedback code identifies a technology and device family; it does not supply the complete motor’s commutation angle or authorise a memory transfer.

After replacement or lost alignment, use the unit-specific method and verify hardware/data compatibility before any write. A clean SRS/SRM bench result must be followed by the separately approved motor assembly/run checks if those are required. No universal numerical angle is claimed.

Production and replacement status

These legacy codes are documented in the May 2015 manual. The current CD-series catalogue uses a different feedback-code scheme and is included for base-model context, not as evidence of current supply for /03 or /04. Confirm whether the exact historical order or a supported successor is available before a replacement recommendation.

Motor applications and related guides

This selection covers G-6-V8 with legacy feedback 04 (SRM 50). The /03 SRS50 is single-turn and /04 SRM50 is multiturn. A /01 resolver or current /10 EnDat guide does not establish the same wiring, test module or alignment data.

Drawings and primary documents

Application evidence: M1 PDF p.28 / printed p.23; M3 pp.6–8,40 (base context only). M2: FASTACT → G/G4xx → Wiring Diagram (Stegmann Absolute Encoders), SRS50/SRM50 and TI-5069/TI-5104 paragraphs.

Page numbering: legacy ordering code is PDF page 28 / printed page 23; connector references are PDF page 23 / printed page 18. The current catalogue’s base-model pages are contextual and do not replace the legacy installation drawing.

FAQ and service enquiry

Does /04 mean the same thing in the latest catalogue?

Use the revision stated here. This guide uses the May 2015 legacy code table. Current EnDat codes 09/10 are not interchangeable with legacy SRS50/SRM50 codes 03/04.

Is G-6-V8 / 04 a complete replacement order?

No. Rated speed, electrical, mechanical and special-version fields must be read from the nameplate and installation drawing. The slash format identifies the scoped service application.

What should I send with a service enquiry?

Provide the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and previous repair/replacement history. Include cable labels and any OEM installation drawing. This lets SpareFaber distinguish a site investigation from a send-in feedback or motor assessment.

Request a UAE site visit or send-in evaluation. Scope, parts and turnaround are confirmed after the fitted configuration and fault are reviewed.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?