Site visit or send-in evaluation
Share the full encoder label with P/R and lead length, PLC or drive input model, shaft size and the highest working speed. Say whether A and B both disappear, the count direction changed or only homing fails. Use the enquiry form to share the details.
What specialist testing can show
A bench check with a compatible load can measure A/B/Z, count, direction and output levels. Mitchell documents TI-5000JX Generic Incremental Encoder for quadrature. Confirm the correct NPN load, supply and input levels or use a rated receiver before connecting. The stand-alone encoder can be tested without energizing the production motor. A TI-3000JX run profile is motor-dependent and was not verified for this application. Mitchell generic quadrature test reference · OMRON output circuit (PDF)
OMRON E6B2-CWZ6C NPN Incremental Encoder technical reference
Find your part number
Read all of E6B2-CWZ6C 1000P/R 2M. CWZ6C identifies the NPN open-collector type, 1000P/R is the pulse resolution, and 2M is the prewired lead length. An encoder from the same 40 mm housing family can have a different output circuit and supply.
| Ordering code | Output | Nominal supply |
|---|---|---|
| E6B2-CWZ6C 1000P/R 2M | NPN open collector A/B/Z, 2 m lead | 5–24 V DC |
| E6B2-CWZ6C 1000P/R 0.5M | Same output and resolution, 0.5 m lead | 5–24 V DC |
| E6B2-CWZ5B 1000P/R 0.5M | PNP open collector A/B/Z, 0.5 m lead | 12–24 V DC |
| E6B2-CWZ1X | Differential line-driver family. Read the full P/R and lead code. | 5 V DC |
Exact orderable models · Output variants and supply tolerances (PDF)
Production and end-of-life status
OMRON’s item index lists the 1000 P/R, 2 m CWZ6C build. Current orderability or a successor for this exact build requires manufacturer confirmation. Reviewed 7 November 2026. OMRON item index
Specifications
| Parameter | Value |
|---|---|
| Measurement | Optical incremental, A/B quadrature and Z index, 1000 P/R |
| Supply | 5 V DC −5% to 24 V DC +15%, maximum 5% peak-to-peak ripple in the OMRON specifications |
| Output | NPN sinking. 30 V DC maximum output load voltage, 35 mA maximum sink current, residual voltage ≤0.4 V at 35 mA. |
| Frequency and speed | 100 kHz maximum response, 6000 rpm mechanical maximum. The receiver can set a lower limit. |
| Fit and shaft load | Ø40 mm housing, Ø6 mm shaft. 30 N radial and 20 N thrust limits. |
| Operating temperature | −10 to +70 °C with no icing. Standard lead length on this code is 2 m. |
Mounting and fit
Bolt the body to the fixed mounting face and connect the Ø6 mm encoder shaft to the measured shaft with a suitable flexible coupling. Align the shafts before tightening the coupling. A rigid or misaligned coupling can load the small encoder bearings and cause cyclic errors or wear. The OMRON drawing shows the Z origin relative to the shaft cut face. Preserve the original machine datum before disturbing it.
OMRON lists E69-C06B for Ø6/Ø6 mm and E69-C68B for Ø6/Ø8 mm couplings. Match the actual shafts and the coupling’s assembly limits. Use the shaft and housing dimensions in the model drawing. OMRON coupling ordering (PDF) · Encoder outline (PDF)
Interface and measuring method
A and B switch as the shaft turns. Their order indicates direction. The Z output marks one reference per revolution. A controller can count four transitions per A/B cycle, so 1000 P/R can produce 4000 counts per turn in 4× mode.
The NPN output sinks current toward the blue 0 V lead when it switches on. A compatible PLC input or approved pull-up circuit supplies the load current. With a bare, unloaded output a meter may give a misleading reading. The power supply and the receiver input rating are separate checks.
Verified wiring
| Wire | Function |
|---|---|
| Brown | +V DC encoder supply |
| Blue | 0 V and output common |
| Black | A pulse output |
| White | B pulse output |
| Orange | Z index output |
| Shield | Bond according to the installation drawing. Keep separate from signal wire identification. |
Connect to a receiver compatible with sinking NPN outputs and confirm the load and input common from its own drawing. The CWZ1X differential lead map is different. CWZ6C NPN output and wire colours (PDF)
Cables inside the motor and at the machine
This is a stand-alone encoder with a factory open-end cable. The 2M suffix identifies the 2 m cable. OMRON cautions against extending the standard non-line-driver cable beyond 2 m. For a longer run, select a documented line-driver installation and matching receiver. Use the exact machine harness map for any cabinet connector or junction. There is no in-motor PCB-to-bulkhead lead on this build. Cable precautions (PDF)
Fault checks
Isolate the machine. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect the mount and cable. Check whether the shaft turns with the machine, the coupling is tight and aligned, and the cable or junction has oil, debris, crushed insulation or loose conductors.
- Test a removable extension separately. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. The prewired lead is part of the encoder. Avoid resistance checks through the encoder electronics.
- Verify supply and pulses. A qualified technician can use an approved breakout fitted while off and measure DC across brown and blue under load. With the correct load in place, compare the A and B waveforms at the encoder and PLC. A slow hand turn is only appropriate if the shaft is safely secured against powered movement and the site procedure permits it.
- Use the symptom. If both pulses work at the encoder and fail at the PLC, check input type, commons, counting mode, filter and cable. If counts drop only at speed, compare P/R × rpm ÷ 60 with the receiver’s limit. If counts are fine but homing fails, check Z and the reset configuration.
Motor and drive applications
An example receiver is OMRON’s CP1L high-speed counter input. The W462 manual section 5-1 lists 50 kHz for differential-phase counting on the documented 24 V inputs and 100 kHz for the listed other pulse modes. In 1000 P/R quadrature mode, 50 kHz corresponds to 3000 rpm by the pulse-frequency calculation. Confirm the exact CPU/input group and circuit. OMRON CP1L W462 high-speed counter manual (PDF)
Angle of alignment and commissioning
The work is coupling alignment, count direction and Z-to-machine datum. Record the incoming PLC settings and home position. Confirm scaling and the Z signal before returning the machine to service. A separate motor commutation encoder, if fitted, uses its own commissioning procedure.
Drawings, pin maps and manuals
- OMRON E6B2-C data sheet (PDF). Page 2 specifications, 3 output circuits and lead colours, 4 mounting and cable precautions, 5 dimensions.
- OMRON CP1L W462 manual (PDF). Section 5-1 for input mode and frequency, and the wiring section for the exact CPU.
- OMRON E6B2-C item index. Compare output suffix, P/R and lead length.