Encoder and resolver technical library

Parker SMH / SMB115 · 10 Nm Heidenhain EnDat Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

PARKER SMH / SMB 115 · 10 Nm — EnDat · MULTITURN — Installation, Repair, Alignment; illustrative workshop cover

Parker SMH / SMB115 · 10 Nm with Heidenhain EnDat Multiturn is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.

Identification · Testing · Specifications · Mechanical fit · Wiring · Alignment · Documents · Service enquiry

Identify the fitted motor and feedback

Identification item Scoped information
Manufacturer / grouped base Parker SMH / SMB115 · 10 Nm
Reference TCG1738; SpareFaber service-guide reference, not an OEM part number
Frame / family 115
Catalogue M0 / stall reference 10 Nm; match the selected catalogue row, conditions and complete fitted order
Cooling / assembly SMH/SMB natural-ventilated catalogue base; identify fan and brake separately
Motor-data source SMH/SMB 115 family M0 10 Nm; data pp.6–7, feedback 12–14, order 18
Mechanical source SMH/SMB resolver reference drawing p.11; interface-specific added length and actual flange/shaft option
Coverage boundary documented multiturn options; base identifier omits complete speed/winding/shaft/brake/factory suffixes

Photograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed/winding fields. B9/D5 is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.

Use Parker application-table data for B9/D5 rather than copying another OEM’s similarly named Heidenhain encoder. Verify actual protocol and device suffix. This is MT-only coverage.

Specialist feedback testing

Device-level test scope: Identify the fitted Heidenhain encoder and its actual protocol before choosing the installed serial selection. Compare serial position/status and documented exposed analogue channels independently. TI-5101 applies to exposed 1 Vpp channels; it does not replace EnDat serial communication or establish a universal motor-bulkhead lead or memory layout.

Record the tester hardware, lead/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.

Test record What the observation establishes
Label and setup match The selected device, electrical interface and supply/excitation match the identified branch
Slow manual movement Direction, continuity, cyclic behaviour and the applicable index/turn transition can be compared
Status / alarm readback Device-reported status can be separated from cable/controller symptoms
Analogue levels where present Compare exposed A/B quality independently of serial position
Before/after report Incoming configuration and each approved service change remain traceable

Motor-run scope: TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture/load, brake handling and speed/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.

Motor data and documented multiturn branches

Parker code Documented MT device Parker application-table reference
B9 EQI1331 17-bit serial; 32 analogue periods
D5 EQN1325 13-bit serial; 512 analogue periods
Turn range 4,096 revolutions Both documented MT choices
Supply 5 V reference Use actual fitted label
Single-turn partner Not listed in this scope Do not invent ST coverage

The catalogue torque reference for this grouped base is 10 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed/winding/cooling condition. Keep standstill/stall, rated-at-speed and momentary peak values separate. Match the actual winding, thermal and cooling conditions.

Only the documented multiturn options are included. A matching single-turn motor order is not inferred.

Use Parker application-table data for B9/D5 rather than copying another OEM’s similarly named Heidenhain encoder. Verify actual protocol and device suffix. This is MT-only coverage.

Mechanical fit, cooling and removal reference

Compare the exact SMH / SMB115 · 10 Nm drawing and full winding, shaft, mounting, brake, cooling and feedback-holder order. Identify fitted connector orientation and cable clearance before removal. Catalogue resolver reference dimensions do not set every encoder envelope. Match the actual flange, shaft, brake and feedback length. A fitted SMH/SMB holding brake requires the documented 5% torque reduction.

Fit item Record and compare
Flange / pilot / mounting holes Use the exact drawing and mounting version, including connector clearance
Shaft / key / coupler Record actual dimensions, insertion depth and machine reference before removal
Encoder mounting Identify holder, coupling, fasteners and mechanical reference from the fitted device
Brake and fan Identify options and added envelope; verify their separate electrical circuits
Seals / coolant / enclosure Match the actual cooling arrangement and ingress-protection build

Mark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.

Mechanical drawings to compare: SMH/SMB resolver reference drawing p.11; interface-specific added length and actual flange/shaft option. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.

Wiring and connector scope

Trace the fitted connector using its stated contact-side view. Keep supply/excitation, signal pairs, protective earth, brake, thermal and motor circuits identified separately.

Circuit / branch Identification boundary
Serial Match fitted EnDat clock/data and full encoder suffix
Analogue B9 and D5 use different documented period counts
Supply / sense Verify actual device and motor connection

Read connector drawings in their stated contact-side view and verify numbering, keyway, male/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.

Keep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.

Test leads, internal loom and machine cable

Connection layer What must be established
Direct encoder plug Exact device connector and compatible bench lead; not automatically a motor-bulkhead connection
Motor internal loom Continuity, shielding, strain relief and any changes made during earlier repairs
Motor feedback / hybrid bulkhead Correct socket, contact view, branch and separate power/brake/thermal circuits
Machine cable Both endpoint pinouts, length/routing, drag-chain damage and shield termination
Drive / tester end Correct installed selection, supply module and interface-specific lead

A device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.

The analogue and serial paths may fail independently. Preserve differential pair integrity and verify supply at the actual device where the documented sense arrangement permits. Do not bridge sense wires or reassign unused contacts without the fitted device's drawing.

No complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor/encoder labels and both connector endpoints are known.

Diagnostic symptoms and useful comparisons

Reported symptom Evidence to collect before changing parts
No position / no communication Supply/return, selected protocol, device identity and isolated cable continuity
Position changes but drive faults remain Status codes, configuration, motor-data interpretation and phase/alignment relationship
Intermittent or noisy behaviour Connector contact, strain/routing, shield integrity and signal quality through each cable layer
Incorrect direction or scaling Recorded device direction, selected protocol/word format and drive scaling; do not rewrite offsets to hide it
Multiturn value unexpected Fitted MT identity, documented turn range and incoming count across a controlled turn boundary
Fault appeared after removal Original reference marks, mechanical holder/shaft relationship, supported offsets and before/after reports

Compare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.

For the documented multiturn branch, verify fitted encoder identity, revolution range and serial/analogue behaviour before changing scaling or offsets. Do not borrow OCT/DSL or another OEM device data.

Alignment, offsets and memory preservation

Capture incoming mechanical reference, supported electrical/commutation angle, offsets, position/status, identity and readable memory before removal or writes. Save a report that identifies the full motor, encoder, fixture, lead and selected software configuration. Preserve valid incoming data as the reference for any approved repair.

After mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.

Only use memory or electronic-alignment functions that are explicitly supported for the identified encoder and motor application. A generic device-level capability does not prove that every manufacturer's memory layout is understood.

If the original relationship or data is unavailable, define a motor-specific recovery method from documented motor/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before/after evidence and the exact change performed.

Service scope, replacement and availability

This is a technical-guide/service listing for Parker SMH / SMB115 · 10 Nm, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.

A replacement decision must compare interface, absolute/analogue behaviour, supply, mounting, shaft/holder, connector route, thermal/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.

Provide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.

Applications and practical service enquiries

The selected 115 frame/family and 10 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment/data.

  • Compare the exact motor and feedback branch during a repair intake.
  • Document a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.
  • Prepare an installation or reinstallation visit with complete labels, drive details and machine reference.
  • Assess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.

Related interface guides for the same base: Classic HIPERFACE — TCG1737 · HIPERFACE DSL — TCG1749 · Resolver — TCG1750 · Incremental with commutation — TCG1759. Each retains its own electrical scope.

Request installation, repair or alignment assessment and include reference TCG1738.

Drawings, manuals and evidence

  • Parker SMH/SMB catalogue PDE2815TCUK. SMH/SMB 115 family M0 10 Nm; data pp.6–7, feedback 12–14, order 18. Mechanical reference: SMH/SMB resolver reference drawing p.11; interface-specific added length and actual flange/shaft option.
  • Mitchell Heidenhain serial testing. Verify fitted device, lead and installed support.
  • Use the selected SMH/SMB motor, feedback, connector and complete-order tables together. Retain interface-specific envelope and catalogue inconsistencies as fitted-device checks.

These references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.

The cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor/encoder installed in a machine.

Frequently asked questions

Is this a complete factory motor order?

No. Parker SMH / SMB115 · 10 Nm is a guide grouping. Match all winding/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.

Does this guide include a singleturn option?

Only the documented multiturn code/device options in this guide are included. A singleturn partner is not inferred.

Can I use another motor's cable or test selection?

Only after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.

Does feedback testing prove a motor-run setup?

No. Exact motor parameters, fixture/load, brake and phase/alignment conventions require their own motor-specific run-test approval.

Can the original alignment and data be preserved?

Capture available incoming identity, mechanical reference, supported angles/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.

How do I request service?

Send full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1738. Installation, repair, alignment and site/send-in scope follow identification.

Send a service enquiry for TCG1738.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?