Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A compatible PROFINET controller can check diagnostics and position in a qualified fixture. Verify communication using the correct terminal cover and a known cable before attributing a fault to the encoder. Confirm exact Mitchell support separately.
Pepperl+Fuchs ENA58IL-S10C4E-1416B17-RH5 PROFINET Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is ENA58IL-S10C4E-1416B17-RH5. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| ENA58IL-S10C4E-1416B17-RH5 | 58 mm housing, Ø10 mm solid shaft, C4 clamping flange, radial RH5 terminal cover. | PROFINET B17, 16-bit singleturn and 14-bit multiturn capacity. |
| ENA58IL fieldbus family | Read the complete shaft and cover options. | Other interface and connection codes require their own controller and wiring documents. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | Up to 16-bit singleturn and 14-bit multiturn, 30 bits total. Verify configured count and preset. |
| Power | 10–30 V DC and approximately 3 W on the exact datasheet. |
| Fit | Ø10 mm solid shaft and clamping flange. RH5 cover has two M20 gland threads. |
| Interface | PROFINET IO and binary position. Use the actual GSDML and project scaling. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Check shaft fit, pilot and flange clearance against the exact drawing. Install the coupling without side loading and keep the cover and cable glands accessible. Preserve the enclosure seals and clamp the cable jackets using the specified glands.
Interface and measuring method
The magnetic sensing system reports absolute angle and turns to a PROFINET controller. The controller uses the configured device name and matching module data to exchange cyclic position. Network connectivity and correct engineering values require separate checks.
Verified wiring
Use the RH5 connection cover terminals in the exact datasheet. The following assignments apply at the cover, with the machine disconnected for termination.
| Group | Functions |
|---|---|
| PWR | PWR+ supply, PWR− 0 V |
| Port 1 | Tx+, Tx−, Rx+, Rx− per the diagram |
| Port 2 | Tx+, Tx−, Rx+, Rx− per the diagram |
Match the correct terminal group and pair polarity. Use the cover and gland instructions for shielding and strain relief.
Cables inside the motor and at the machine
The radial cover uses terminal connections and M20 glands. Select the machine's approved PROFINET cable and supply conductors, checking shield termination and network topology. Obtain the exact loom or terminal cable number from the machine wiring record.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Device absent from controller | Check supply at PWR, network pairs, port selection and assigned PROFINET name. |
| Device visible, PLC value implausible | Check GSDML revision, telegram mapping, scaling and direction. |
| Position differs after mechanical work | Check coupling slip and re-establish the documented preset at the machine reference. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use with a compatible PROFINET IO controller on the documented rotary axis. Check the approved update rate, telegram and configuration. Confirm housing, shaft and cover options from the full label.
Angle of alignment and commissioning
Record the device name, controller configuration, count direction and preset before replacing the unit. Set the mechanical coupling, confirm raw position at known motion, then restore the machine reference and verify it after restart.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Ordering and terminal diagrams. The exact datasheet identifies B17, C4 and RH5 and separates the power and network terminals.