What specialist testing can show
TI-5000JX bench. Generic Incremental count. Mitchell identifies the OEM connector pinout as distinct from the standard RHS arrangement.
TI-3000JX motor run. Exact motor-run setup open.
Starting lead. TI-5018 on the documented OEM 79994-023 arrangement
RENCO RHS21D 79994-023 ABZ Incremental Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| RHS21D · 79994-023 | Exact OEM part in Mitchell’s Other Variations subsection. Match the complete label and original motor wiring. |
| RCH20D · 79994-004 | Separate commutation-equipped model with different test leads. |
| Standard RHS encoder | Use the OEM 79994-023 view rather than a generic RHS drawing. Mitchell specifically flags a ground-pin difference. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position | ABZ quadrature with reference on the documented OEM part. |
| Counts | Mitchell describes an 8,000-count-per-turn test, equivalent to 2,000 periods in four-edge decoding. |
| Connector and test | OEM 8-contact AMP connection in the cited example. TI-5018 is the documented test lead. |
Interface and measuring method
A and B convey position change and direction. Z gives a reference. Mitchell’s 79994-023 example has no commutation outputs, so check the motor’s separate commutation path if the drive reports a commutation fault.
Mounting and fit
Use the complete encoder and motor drawings to confirm the shaft or hub fit, body retention and exit clearance. Preserve the installed index reference before changing the mounting.
Wiring and connector scope
Use the OEM 79994-023 view and Mitchell TI-5018 sheet. The connector assignment differs from standard RHS wiring. Identify the supply and return before using any bench power.
Internal motor and machine cables
TI-5018 is the documented tester lead. Obtain the original machine and internal harness references for the actual motor. Match the OEM ground and shield arrangement.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| No response after fitting a standard RHS cable | Verify the exact 79994-023 ground and supply assignment using the fitted diagram before powering again. |
| A/B reads but the axis will not reference | Trace Z separately and check the machine’s referencing sequence. |
| Position works but the drive reports commutation | Check the actual motor feedback configuration and its separate commutation path. |
Angle of alignment and commissioning
Record index and mechanical reference before removal. Preserve the correct coupling position and verify the motor’s separate commutation source under the OEM procedure.
Motor and drive applications
Electrocraft / Giddings & Lewis applications. Exact motor order open.
Check the OEM part number before using a standard RHS pin map. Identify where the motor obtains commutation separately.
Drawings, pin maps and manuals
- Renco Encoders. Other Variations. Exact 79994-023, nonstandard 8-pin AMP wiring and TI-5018.
- Mitchell pin and test cable references. Use the TI-5018 sheet and verified OEM connector view.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.