Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Renishaw documents ADTi-100 and ADT View for supported installation and fault diagnosis. A differential receiver can also check quadrature and Z with the correct supply and termination. Check exact Mitchell profile and adapter compatibility before using that equipment.
Renishaw ATOM DX A4A0Z15A10F Optical Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is A4A0Z15A10F. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| A4A0Z15A10F | Cabled 40 µm linear or partial-arc readhead, 1.5 m cable, 9-way D-type. | 0.5 µm resolution, 10 MHz clocked output option, three-state alarm. |
| A4A0X15A10F | Similar cabled 40 µm format. Confirm compatible scale and mounting drawing. | 1 µm resolution. Update the controller scale factor for this distinct order. |
| A4L0Y00Z10F | Separate top-exit configuration. Confirm its applicable cable and scale. | 0.1 µm resolution. Its connector and output setup differ. |
Production and end-of-life status
Renishaw's product store lists A4A0Z15A10F and links technical documentation. Confirm current stock, production and scale availability for the exact order.
Specifications
| Parameter | Value and scope |
|---|---|
| Compatible scale | RTLF40 or RKLF40 for the reference A4A0Z15A10F product, 40 µm pitch. |
| Output | Digital RS-422A A/B plus reference Z. Interpolated resolution 0.5 µm, 10 MHz clocked option. |
| Connection | 1.5 m attached cable with 9-way D-type A termination, 5 V supply per data sheet. |
| Alarm | Three-state output alarm for this order. The A connector has no separate single-ended alarm pin. |
| Fit | Use the ATOM DX and RTLF installation guide for ride height, pitch, roll, yaw and reference setup. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Match the head to the scale before fitting. Use the correct scale guide and Renishaw setup gauge to establish ride height, yaw, pitch and roll. Sweep the usable travel and check setup indication or diagnostic signal strength. A head can look aligned at one point while the rail flexes enough to lose signal elsewhere.
Clean and handle the scale according to the manufacturer instructions. Protect the head's cable from strain and keep the reference mark arrangement visible for setup.
Interface and measuring method
The readhead reads the optical grating, interpolates inside the head and sends differential A and B position pulses plus Z reference. The controller converts edge counts to travel. The 10 MHz option describes the chosen output timing. Apply the data-sheet speed table and the receiver limits together when checking a dropout at speed.
Verified wiring
Use the 9-way D-type column marked A in data sheet L-9517-9736-05-A, page 18. Verify mating face numbering on the connector. Other ATOM DX D-type and JST terminations have different pinouts.
| Function | Pin or pair |
|---|---|
| 5 V / 0 V | 5 / 1 |
| A+ / A− | 2 / 6 |
| B+ / B− | 4 / 8 |
| Z+ / Z− | 3 / 7 |
| Remote CAL | 9, use the documented method |
| Shield | Connector case |
Cables inside the motor and at the machine
Start with the factory 1.5 m cable and A termination. Use the Renishaw-approved extension for the chosen connector and receiver arrangement. The sheet specifies a separate maximum cable length to ADTi-100. Obtain an exact extension order from Renishaw with both end drawings and total length.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Setup indicator varies across travel | Inspect scale flatness and head ride height and attitude along the full length. |
| Good setup but incorrect travel | Compare A/B wiring and controller resolution against the 0.5 µm build. |
| Reference missing | Verify scale reference type, calibration and the Z pair at the receiver. |
| Signal lost only at high speed | Check receiver frequency, selected output clock, termination and cable loading. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This is an optical linear or partial-arc incremental system for the specified scale. Confirm the machine's scale type and control input, particularly if a physically similar readhead uses a different grating pitch or resolution.
Angle of alignment and commissioning
Set and verify the readhead geometry, then use the Renishaw calibration and reference-mark procedure for the actual scale. Confirm count direction and machine home. The model's alignment task is optical geometry and datum rather than a motor electrical angle.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Renishaw ATOM DX with RTLF installation guide. Follow the matching scale and head configuration.
- Renishaw D-type and JST pin assignments. Use the A column for this exact cabled head.