What specialist testing can show
TI-5000JX bench. Verify M2 and the fitted encoder, then use the scoped EnDat and Rexroth memory tests.
TI-3000JX motor run. Confirm the fitted motor, exact feedback selection and stored setup before a motor run.
Starting lead. TI-5093 on the documented MSK connection. Verify direct cable separately by the fitted HEIDENHAIN ID. Module TI-5104 on the Mitchell standard MSK setup.
Bosch Rexroth IndraDyn S MSK M2 Multiturn EnDat 2.1 Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MSK M2 | Multiturn absolute EnDat 2.1 motor feedback in the Rexroth option table. |
| MSK S2 | Singleturn EnDat 2.1 counterpart. Check turn information and order before replacement. |
| MSK S1 / M1 | HIPERFACE options in the motor table. The motor family and plug alone do not establish interface or memory compatibility. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Measuring method | Optical absolute position and multiturn tracking for the M2 option. |
| Connection | Mitchell lists TI-5093 with TI-5104 for the standard MSK feedback connection. TI-3025 is the power lead in that setup. |
| Motor data | Mitchell provides an MSK-specific memory profile. Verify the exact part, read permission and data compatibility. |
Interface and measuring method
The controller reads the EnDat position and uses motor-specific data for the servo setup. A readable encoder can still produce a motor identification or reference fault when the stored information differs from the fitted motor.
Mounting and fit
Use the complete MSK frame and feedback order to obtain the rear assembly and fitted encoder drawing. Preserve the locating reference, seating, routing and original hardware. Confirm the actual HEIDENHAIN label before checking mounting fit.
Wiring and connector scope
Use the MSK connection table for the fitted option and plug orientation. Match the clock/data, supply and analogue paths at the scoped connector. A shared connector shell between HIPERFACE and EnDat does not imply the same circuit.
Internal motor and machine cables
Use the Rexroth motor and drive orders for the external feedback cable. The short internal lead follows the fitted encoder and motor assembly. Keep the TI-5093 fixture and TI-3025 power lead separate from the machine cable order.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position reads but the drive reports a motor mismatch | Compare the reported motor memory and fitted M2 order. |
| Missing serial reply after a cable change | Check the EnDat connection, pin view and approved fixture against the motor order. |
| Position and turn data disagree | Verify the selected M2 profile, direction and received data before changing settings. |
Angle of alignment and commissioning
Record the incoming commutation reference and keep a read-only copy of the original MSK memory. A specialist should compare the original motor ID, offset and replacement revision before applying the Rexroth and Mitchell commissioning procedure.
Motor and drive applications
Rexroth MSK with fitted M2 option
Distinguish M2 multiturn EnDat from the S1 HIPERFACE and S2 singleturn EnDat options.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth MSK support. MSK EnDat scope, test cable and motor-memory procedure
- Bosch Rexroth MSK project planning. Manufacturer-authored DOK-MOTOR MSK planning document. Section 4.3, M2 and S2 encoder option table.
- Rexroth Motors. Reference for the fitted feedback or motor option.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.