Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell documents BRI_I2C in Athena and a spindle feedback identifier in memory.
TI-3000JX motor run. Mitchell excludes the 2AD asynchronous spindle motors from TI-3000JX run testing.
Bosch Rexroth Indramat 2AD104C-B05OB1-CS06-A2N1 Option 6 Spindle Feedback technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| 2AD104C-B05OB1-CS06-A2N1 | Motor-order example. The feedback digit 6 identifies digital servo feedback in the 2AD104 order key. |
| Option 7 | Related 2AD feedback with integrated multiturn absolute function. Keep its assembly and documentation separate. |
| Options C and D | Distinct incremental feedback branches in Mitchell’s article. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Motor type | Asynchronous, air-cooled spindle motor. |
| Feedback | Option 6 digital servo feedback. The actual feedback assembly part number remains open. |
| Bench profile | BRI_I2C selection in Athena for the documented 2AD options 6–9. |
| Memory scope | Mitchell describes a spindle feedback identifier rather than a full servo motor parameter file. |
Mounting and fit
Use the 2AD104 motor drawing for feedback housing clearance and the approved removal procedure. Inspect the bulkhead and connector retention before opening the spindle feedback assembly.
Interface and measuring method
The digital feedback option provides position information to the spindle drive. Treat an identifier read and a repeatable movement reading as separate checks. A readable identifier does not prove the entire feedback path is healthy.
Wiring and connector scope
Mitchell supplies a feedback connection figure for the options 6–9 arrangement. Use it with the exact motor drawing and identify connector orientation before comparing supply, signal and shield conductors. The C/D option pin maps belong to other builds.
Cables inside the motor and at the machine
Use TI-5021 and TI-5104 for the documented bench connection. The installed spindle loom and the Mitchell test lead are separate items. Check the fitted motor connector and loom label.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Identifier reads but the position is unstable | Check mechanical seating, signal integrity and the feedback board connection. |
| No feedback detected after a connector repair | Confirm option 6 and compare the fitted bulkhead with the correct options 6–9 drawing. |
| Spindle alarm persists with verified feedback | Review drive alarm history and the installed motor-to-drive harness before replacing the encoder. |
Motor and drive applications
2AD104C-B05OB1-CS06-A2N1 Check the exact ID, drive and connector before applying an installation or test procedure.
Distinguish a cable or feedback-board issue from a drive fault. Obtain the fitted feedback assembly ID from the motor.
Angle of alignment and commissioning
Mitchell states that these asynchronous motors do not require feedback commutation alignment. Retain any machine spindle-orientation or reference settings and verify them with the spindle drive procedure after reassembly.
Drawings, pin maps and manuals
- Indramat 2AD support. Overview and Feedback Connections. Options 6–9.
- Rexroth 2AD project planning manual R911260576. The 2AD104 type code separates option 6 from variants with integrated absolute feedback.