What specialist testing can show
TI-5000JX bench. Mitchell documents direct encoder testing and the Rexroth memory test for this KSM/KSD branch.
TI-3000JX motor run. Confirm an approved motor-only fixture and exact motor data. Evaluate the integrated drive with its corresponding Rexroth Mi controller.
Starting lead. TI-5094 direct with TI-5104 for the documented HIPERFACE setup. Module TI-5104 on the documented direct HIPERFACE setup.
Bosch Rexroth KSM01.2B-061C M1 KSD061C Multiturn HIPERFACE Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| KSM01.2B-061C-35N-M1-HP2-SE-NN-D7-NN-FW | Full integrated motor-drive order in the Mitchell example. M1 is the multiturn HIPERFACE motor-feedback option. |
| KSD061C-0350-NN-M1-1P2-NNNN | Stored motor identity for that exact KSM example. Compare the complete KSD value and the nameplate together. |
| S1 / M3 and other KSM codes | Separate feedback variants. The fitted encoder label and type code determine the interface and connection. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| M1 feedback | Optical multiturn absolute HIPERFACE with 128 analogue signal periods per turn in the Rexroth type code. |
| Direct test | TI-5094 with TI-5104 on the documented direct encoder arrangement. |
| Drive scope | IndraDrive Mi has separate integrated drive electronics. Test drive-side behavior using the matched controller and Rexroth procedure. |
Interface and measuring method
HIPERFACE supplies absolute position through the serial link and movement information through sine and cosine channels. The memory can hold both the motor identity and an alignment offset. Compare those records separately from raw signal quality.
Mounting and fit
Use the exact KSM manual for access to the motor and drive assembly. Preserve encoder seating and cable routing. Follow the OEM disassembly procedure and electrical isolation for the integrated unit.
Wiring and connector scope
Use the matched KSM drawing to separate direct encoder feedback, motor phase, brake and thermal connections. Match the fitted HIPERFACE connector before using TI-5094 and the adapter.
Internal motor and machine cables
TI-5094 accesses the documented encoder plug. The internal motor loom and machine-side IndraDrive Mi connection are separate assemblies. Find the actual parts by KSM and KSD identity and plug revision.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| The memory shows KSD and the nameplate shows KSM | Compare the full documented pairing before treating the difference as corrupt data. |
| Good direct feedback and the integrated drive still faults | Use the matching controller and OEM diagnostics to isolate the drive-side fault. |
| Fault follows a replacement | Verify the incoming and replacement identity, turn mode, fitted connector and actual commutation. |
Angle of alignment and commissioning
Save and compare the incoming memory and measured reference before removal. Verify the KSD motor match and the actual angle under the documented procedure before any memory transfer or re-commissioning.
Motor and drive applications
IndraDrive Mi KSM / internal KSD motor identity
Record actual encoder suffix, KSM nameplate, KSD memory and internal loom before work.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth KSM Integrated Drive Motors (KSD). KSM01.2B-061C-35N-M1-HP2 and matching KSD061C
- Rexroth IndraDrive Mi KSM instructions R911322511. Rexroth-authored installation and M1 feedback code reference.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.