What specialist testing can show
TI-5000JX bench. Mitchell describes using A, B and Z on this cable in the C0 setup. Check the actual connector and reference path.
TI-3000JX motor run. Encoder bench diagnosis only in the documented scope for these asynchronous spindles.
Starting lead. TI-5010 for the documented C0 connection.
Bosch Rexroth MAD / MAF C0 Incremental Spindle Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MAD / MAF C0 | Incremental encoder option in Rexroth’s motor encoder table. |
| MAD and MAF | Air-cooled MAD and liquid-cooled MAF are separate asynchronous spindle motor families. Match the fitted motor order. |
| M0/S0 and M2/S2 | Different Indramat I²C or EnDat options with separate tester setups. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| C0 analogue tracks | Rexroth specifies 2,048 signal periods per turn and 1 Vpp in its C0 option table. |
| Reference | Mitchell’s C0 connection exposes A/B and the Z reference. |
| Bench connection | Use TI-5010 on the documented C0 plug. The commutation circuits of the fixture do not apply to this spindle option. |
Interface and measuring method
The controller interpolates analogue A/B to read relative spindle motion. The reference signal is a separate check. A usable speed indication can coexist with an orientation fault when the reference circuit fails.
Mounting and fit
Use the exact motor type and rear encoder drawing. Check seat, coupling and cable routing before replacement. Respect the fitted cooling arrangement and the applicable machine isolation procedure.
Wiring and connector scope
The C0 connection table below applies to the X3 view and INS0379 coupling in the Rexroth PR07 drawing. Match the fitted drawing before measuring. Mitchell Image 2 shows the supported bench connection.
| Contact or circuit | Documented scope |
|---|---|
| 1 / 2 | A +/−. |
| 11 / 12 | B +/−. |
| 3 / 13 | Reference R +/−, identified as Z in the Mitchell bench scope. |
| 7 / 10 | 0 V / 5 V in the stated C0 drawing. |
| 15 / 16 | 0 V sense / 5 V sense. Confirm the installed wiring and specified supply before testing. |
Internal motor and machine cables
The cited Rexroth C0 drawing names INK0720 with the INS0379 coupling. Match the full motor order and drive before ordering. TI-5010 is the documented Mitchell bench fixture.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Spindle rotates but orientation fails | Check Z reference activity and the machine orientation setup independently of A/B. |
| No valid A/B on the fixture | Confirm C0 on the type code and the connector view before checking analogue levels. |
| Intermittent counts under motion | Inspect cable strain, seating and the isolated feedback harness. |
Angle of alignment and commissioning
Mitchell documents encoder bench diagnosis for the asynchronous spindle. Follow the machine builder’s procedure to verify spindle direction, reference and orientation after mechanical work.
Motor and drive applications
IndraDyn A MAD or MAF asynchronous spindle, C0 option
Identify C0 and isolate its incremental feedback path, with the M2/S2 EnDat setup documented separately.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth MAD & MAF Asynchronous Motors. Feedback Connections, Incremental Encoder Option C0 and Image 2
- Generic Incremental Quadrature Pulse Encoders. Supplementary reference for the stated model or setup.
- Rexroth IndraDyn A MAD/MAF project planning manual. Encoder option table and frame-specific mechanical and electrical documentation.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.