Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a matched BiSS-C controller or RLS-supported interface for position, register and CRC checks. Log faults against shaft angle to distinguish readhead spacing from a harness issue. Exact Mitchell compatibility for this readhead and motor assembly requires confirmation.
RLS AksIM-2 MB049 BiSS-C Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is MB049DCC19BDNP00. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| MB049DCC19BDNP00 | MB049 board readhead for an MRA049 ring, N connector and documented P-option build. | BiSS-C bidirectional with register access, 19-bit singleturn. |
| MB049DCC19MDNP00 | Related P-option readhead for MRA049. | 19-bit singleturn plus 16-bit multiturn counter. Check settings and power-off behavior. |
| MB029DCC18MFNP00 | Related P-option readhead for a different ring size. | Different resolution and geometry. Verify the matching ring and controller. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Reference build | MB049 readhead, MRA049-compatible ring, DCC BiSS-C and 19B singleturn resolution code. |
| Supply | 4.5–5.5 V at the readhead connector. MBD01 specifies supply rise time under 20 ms. |
| Interface | Differential MA and SLO. Use the exact BiSS-C controller frame and timing from MBD01. |
| Special environment | P-option is listed for pressure and vacuum applications with distinct timing requirements. Use the manufacturer conditions for the complete assembly. |
| Installation dimensions | Use the MRA049 ring drawing and corresponding MB049 readhead drawing for concentricity, mounting and ride height. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The magnetic ring and readhead are separate. Verify the ring's full code and mounting datum, then compare ride height around the full circumference against MBD01. A ring can be centered but still have an uneven gap due to tilt or shaft runout. Inspect the readhead bracket, ring retention and nearby magnetic or metallic contamination before moving the sensor.
Interface and measuring method
The BiSS-C master provides the MA clock pair. The encoder replies on SLO with position, status and CRC, and the DCC configuration supports register access. Diagnose a valid position and status warning separately from a CRC or timeout. Use the P-option clock and timing guidance where the operating environment requires it.
Verified wiring
The N-option low-profile 8-pin connector is shown in MBD01 Electrical connections. Use the numbered face and correct mating part. These are readhead contacts, not D-sub cable contacts.
| Pins | Function |
|---|---|
| 1 / 2 | 5 V / 0 V |
| 3 / 4 | External isolated temperature sensor connections if applicable |
| 5 / 6 | MA+ / MA− |
| 7 / 8 | SLO+ / SLO− |
Follow the specified cable, termination and shield routing. Verify any receiver-side D-sub against the matching cable assembly table.
Cables inside the motor and at the machine
MBD01 lists N-option cable assemblies including ACC015 and ACC061. Match the chosen length and flying-lead or connector end in the assembly table before ordering. For the exact readhead keep the clock and data pairs together and use the approved grounding arrangement. An OEM motor or joint loom requires the builder's own drawing.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| CRC or timeout at all positions | Check supply rise and voltage at the head, MA and SLO pair integrity, controller frame and termination. |
| Signal warnings at the same shaft angle | Inspect ride height over a full turn and check ring seating and runout. |
| Readout smooth but axis zero is wrong | Verify the reference stored in the controller and the physical ring orientation before setting a new datum. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
RLS documents off-axis magnetic feedback for compact assemblies and lists this exact P-option model in its special-environment section. Match the ring, bearings, readhead electronics and drive configuration to the machine. Verify environmental qualification for the assembled system.
Angle of alignment and commissioning
Align the ring and readhead mechanically, verify the gap and diagnostic status over a turn, then confirm direction and machine datum. For a motor joint, use its own electrical reference procedure. Preserve any OEM settings before replacing the head or ring.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- RLS MBD01 AksIM-2 datasheet. See Electrical connections, special-environment variants, BiSS and Cable assemblies.
- RLS separate redundant family. Compare the device identity and connector before using a redundant model's documentation.