Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A supported SPI master and logic analyzer can verify response words, check bits, angle and timing with a known-good harness. Start with the documented voltage, connector and capture setup. Check exact Mitchell support before proposing a TI-5000JX or TI-3000JX test.
Same Sky AMT222B-V 14-bit SPI Absolute Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is AMT222B-V. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AMT222B-V | Radial connector. Modular kit with shaft sleeves and mounting bases. | 14-bit singleturn absolute SPI, 16,384 positions per revolution. |
| AMT222A-V | Radial connector kit. Compare the supplied sleeve and base. | 12-bit singleturn SPI. Firmware must use the correct data width. |
| AMT223B-V | Axial connector exit. Check rear clearance and cable path. | 14-bit singleturn SPI. Confirm mounting before interchange. |
Production and end-of-life status
Same Sky provides an AMT222B-V product record and AMT22 documentation. Confirm current production and the kit contents for the orderable suffix.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 14-bit, one revolution, 16,384 positions for AMT222B-V. |
| Supply | 5 V DC nominal. Follow the AMT22 electrical table for tolerance, current and logic levels. |
| Interface | SPI, with position check bits. Use the AMT22 timing diagram for chip select and interbyte delays. |
| Shaft fit | Modular sleeve system for the shaft diameters shown in the kit table. The radial B kit has the AMT222 exit. |
| Connection | Six contacts. The AMT22 drawing names Molex 502578-0600 as the mating connector. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Measure the shaft and choose the matching kit sleeve. Use the Same Sky installation spacers and tools to locate the hub axially, then fasten the correct base and seat the encoder body. Route the radial cable so the cover and strain relief clear the machine. An encoder that clips onto a mispositioned rotor may still produce a valid-looking number until shaft motion shifts the hub.
Interface and measuring method
The controller clocks out a 16-bit AMT22 position response. The 14-bit B version uses two check bits and 14 position bits. Validate both check bits before using the position. Keep SPI clock mode, command bytes, chip-select and interbyte timing in step with the datasheet. Check frame validity across a turn instead of relying on a single stable reading.
Verified wiring
The manufacturer datasheet connector drawing on page 5 gives the AMT222 pin order. Confirm the side shown before assembling the mating connector.
| Pin | Signal |
|---|---|
| 1 | +5 V |
| 2 | SCLK |
| 3 | MOSI |
| 4 | GND |
| 5 | MISO |
| 6 | CS |
Match the host logic levels to the datasheet and use an approved breakout. Verify supply against the encoder ground and keep the documented return with the data path.
Cables inside the motor and at the machine
Same Sky lists Molex 502578-0600 for the mating connector. Source the contacts and tooling for that housing and use the drawing to verify the end-to-end map. Check board or controller end independently. Keep high-frequency SPI connections within the limits and topology in the machine design.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| All ones, all zeros or no change | Check supply, CS timing, MISO and the host's SPI setup before replacing the encoder. |
| Check bits fail intermittently | Compare the bench harness and machine wiring, probe timing and check return path and connector seating. |
| Position valid with a fixed offset | Inspect the sleeve and hub, then compare electrical zero with the saved machine datum. |
| Position wraps every revolution | The B kit reports singleturn position. Check how the controller maintains the axis reference across turns. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this guide for the AMT222B-V modular encoder on compatible host electronics. A machine that reads the correct frame still needs a documented relationship between count, shaft direction and datum. AMT22 kit variants share the family name while the full code identifies resolution and connector orientation.
Angle of alignment and commissioning
Record mechanical shaft datum and existing zero before disturbing the rotor. Where authorized by the OEM, use the AMT22 zero command for this singleturn build at the known datum. Read the value back and verify direction and rollover through permitted travel. A motor controller's commutation procedure is separate.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Same Sky SPI example. Refer to manufacturer timing and checksum logic. Verify signal levels for the actual controller.
- AMT22 mechanical and connector drawings. Compare radial AMT222 and axial AMT223 drawings.